IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
questions concerning installation, operation or maintenance of this equipment.
2M-Z17083
p/n
Rev. B
WELLS MANUFACTURING
10 Sunnen Dr., St. Louis, MO 63143
telephone: 314-678-6314
fax: 314-781-2714
www.wellsbloomfield.com
VENTLESS UNIVERSAL
IL2629a
OWNERS MANUAL
HOOD SYSTEM
for
ELECTRIC OVENS,
PROOFERS AND
HOLDERS
MODEL
WVC46
WVC46X
Manual Includes
INSTALLATION
USE & CARE

EXPLODED VIEW

PARTS LIST

WIRING DIAGRAM

14
M523
523
0708

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WVC46 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wells WVC46

  • Page 1: Exploded View

    Additional manuals are available from your WELLS DEALER. THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any questions concerning installation, operation or maintenance of this equipment.
  • Page 2: Warranty

    LIMITED WARRANTY STATEMENT Unless otherwise specified, all commercial cooking charged by Wells Manufacturing for its products are based equipment manufactured by Wells Manufacturing is upon the limitations in this warranty. Seller’s obligation warranted against defects in materials and workmanship under this warranty is limited to the repair of defects without...
  • Page 3: Table Of Contents

    PARTS & SERVICE CUSTOMER SERVICE DATA INTRODUCTION Thank You for purchasing this Wells Manufacturing appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
  • Page 4: Features & Operating Controls

    FEATURES & OPERATING CONTROLS 17 8 7 17 Nameplate WVC-46 Nameplate WVC-46X IL2631c Ventilator Section Operating Features & Controls...
  • Page 5: Features & Operating Controls

    FEATURES & OPERATING CONTROLS continued FEATURES & OPERATION CONTROLS ITEM DESCRIPTION COMMENT VENTILATOR EXHAUST DUCT, FRONT Exit point for ventilator airflow - on front of unit. DO NOT BLOCK VENTILATOR FAN Provides air movement for ventilation HI-EFFICIENCY/CHARCOAL FILTER Removes grease and smoke particles. Also assists in cooking odor PACK removal.
  • Page 6: Precautions & General Information

    This appliance is made in the USA. Unless otherwise noted, this related shutdown. Spare appliance has American sizes on all hardware. filters can be purchased from any authorized Wells servicer or calling Wells at (314) 678-6314.
  • Page 7: Agency Listing Information

    AGENCY LISTING INFORMATION This appliance conforms to NSF Standard 4 for sanitation only if installed in accordance with the supplied Installation Instructions and operated and maintained in accordance with the instructions in this manual. This appliance is ETL listed. 3169406 UL710B Recurculating System INSTALLATION...
  • Page 8: Under-Hood Appliance Limitations

    INSTALLATION (continued) UNDER-HOOD APPLIANCE LIMITATIONS: Appliance must be installed per manufactures instructions. Electrical appliances only. Not Intended for gas fired units. All appliances under the hood must be connected to the hood appliance interlock circuit. All appliances must meet the requirements outlined in the cooking appliance limitations chart below. EQUIPMENT PARAMERTUER - WVC-46 (X) Parameters Appliance Max Cooking...
  • Page 9: Service Technician Installation Notes

    INSTALLATION (continued) SERVICE TECHNICIAN INSTALLATION NOTES This ventilator hood is to be used with light-duty and medium-duty electrically powered cooking appliances only. DANGER: • DO NOT attempt to use this ventilator hood with gas-fired units. SUFFOCATION HAZARD • DO NOT use this ventilator hood with electrical appliances whose Do not attempt to use this dimensions or wattage characteristics exceed those defined in the ventilator with gas-fired units.
  • Page 10: Site Preparation

    INSTALLATION (continued) Site Preparation 1. Provide clearance around installation site to safety rig and lift equipment into its final position. Consider general service and installation space when locating unit. 2. Thoroughly review the plans and specification of the project. 3. Determine the exact location in which the cooking hood will be installed and verify that there are no interferences, which will prevent proper installation.
  • Page 11: Mechanical Installation

    INSTALLATION (continued) MECHANICAL INSTALLATION The following is a step-by-step procedure for installation of the Recirculating Hoods. 1. Uncrate the hood, being very careful not to dent or scratch the outer surface. NOTE Report any damage to the delivering freight carrier and file a claim if appropriate. Refer to the installation drawing for typical details of the ventilation system prior to hanging the hood.
  • Page 12: Discharge Direction Modification

    The unit comes with the Vertical Discharged Adapter Assembly & Close- Off Adapter Bracket, these parts can be re-aquiired by purchasing pn N1-WL0645 from any authorized Well Servicer or directly from Wells by calling (314) 678-6314. Vertical Discharge...
  • Page 13 INSTALLATION Install the vertical adapter at the SLIDE BRACKET OVER discharge of the blower. BLOWER DISCHARGE, SECURE WITH 8-32 SCREWS Secure adapter bracket use (6) STEP 10 - INSTALL FIRE DAMPER 8-32 screws. (Not provided) INTO BLOWER ADAPTER 10. Remove the fire damper from the horizontal discharge and install it into the vertical discharge adapter assembly.
  • Page 14: Electrical Installation

    INSTALLATION ELECTRICAL INSTALLATION Refer to the nameplate on the ventilator. Verify ELECTRICAL SERVICE POWER. Voltage and phase must match the nameplate DANGER: specifications, and available electrical service amperage must meet or SUFFOCATION HAZARD exceed the listed amperage. Refer to specifications listed on page 1 of this manual.
  • Page 15: Ansul® Installation & Setup

    INSTALLATION continued DANGER The alarm relay is activated by the Ansul® fire detection system. If the FIRE HAZARD installation includes a building alarm system, connect to terminals T7 & T8 of the terminal block in supply connection box. These terminals are Fire suppression system configured from the factory for normally open operation.
  • Page 16 INSTALLATION continued DANGER FIRE SUPPRESSION SYSTEM INSTALLATION (continued) BURN HAZARD The MANUAL PULL STATION and any similar REMOTE MANUAL Any additional remote pull PULL STATION will activate the fire suppression system when the station must NOT be installed ring on the pull station is pulled to its full extent. on the front of the cooking appliances, Discharge of the fire...
  • Page 17: Filter Installation

    DO NOT operate any cooking Use only genuine Wells replacement parts and filters, appliance unless the grease call (314) 678-6314 or your authorized Wells service agent. Parts cup is installed. supplied by others will void your warranty and may not provide safe operation.
  • Page 18: Operation

    Filter packs cannot be appliances. cleaned. POWER If the SERVICE REQUIRED light Wells Manufacturing assumes illuminates, the filter pack is restricted to no liability for loss of business the point of insufficient airflow for proper due to filter related shutdown.
  • Page 19: Cleaning Instructions

    CLEANING INSTRUCTIONS PRECAUTIONS: Disconnect unit from electric power and allow to cool CAUTION: Cover frypot to prevent oil contamination HOT SURFACE FREQUENCY: Weekly Exposed surfaces can be hot to the touch and may cause TOOLS: Mild detergent, clean non-abrasive towels burns.
  • Page 20: Cleaning Instructions

    CLEANING INSTRUCTIONS PRECAUTIONS: Disconnect unit from electric power and allow to cool CAUTION: Cover cooking surfaces and frypots to prevent HOT SURFACE contamination. Exposed surfaces can be hot FREQUENCY: Monthly to the touch and may cause burns. Allow unit to cool TOOLS: Mild detergent, clean non-abrasive towels before cleaning.
  • Page 21 REQUIRED MAINTENANCE IMPORTANT: USE AND MAINTENANCE SHALL BE IN ACCORDANCE WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION Per NFPS 96, a signed and OF COMMERIAL COOKING OPERATIONS, N.F.P.A. 96 (current dated VENTILATOR HOOD edition). MAINTENANCE LOG must be maintained on the premises, and be made 3-MONTH MAINTENANCE: available for inspection by the...
  • Page 24 ANSUL A N S U L IN C O R P O R AT E D MATERIAL SAFETY DATA SHEET ® M A R IN E T T E , W I 5 4 14 3-2 54 2 ANSULEX Low pH Q U IC K ID E N TIFIE R (In P la n t C o m m o n N a m e ) E m erg e nc y M a n u fac tu re r’s...
  • Page 25 SECTION 5 - HEALTH HAZARDS ANSULEX Low pH (continued) Th res h o ld N o ne E s tab lish ed L im it Va lu e : R o u te s o f E n try: Irritan t E ye C o n tac t: S kin C o n ta c t: Irritan t...
  • Page 26: Troubleshooting Suggestions

    Filter pack plugged Replace filter pack Fire damper in exhaust collar has closed Contact an authorized Wells service agent for repairs SERVICE REQUIRED light lit (cooking One or more vacuum sensing lines or ports plugged, or Contact an authorized Wells service agent for repairs appliance not operating) sensing line dislodged.
  • Page 27: Wiring Diagram

    WIRING DIAGRAM WVC-46 208/240 VOLT AC 60 HZ L2 POWER SWITCH L2 12FLA 60RLA 120VAC 120 VOLT 8FLA 48LRA 250VAC WARNING CHANGE 18A, 277VAC RES BUZZER CHANGE PREFILTER FILTER LIGHT PACK LIGHT FILTER PACK BUILDING INTERLOCK RT ALARM RELAY PRE-FILTER N.O.
  • Page 28: Exploded View & Parts List

    EXPLODED VIEW & PARTS LIST Filter Maintenance Baffle Filter: 16” x 20” Pre-Filter Hood Part No: 2I-Z16860 Part No: 2I-Z16882 Grease Cup Part No: 2D-Z14672 Filter HEPA/Carbon Pack Part No: N1-WL0171 Model: WVC-46 Maintenance Parts SK2655 Rev. A, 6/24/2014...
  • Page 29 EXPLODED VIEW & PARTS LIST Suppression System Model: WVU-46 Ventless Hood System SK2657 Rev. - 5/28/13 Suppression System WVC-46, Suppression System Fig No Part Number Description 2O-307481 ADAPTER SWIVEL ANSUL 2O-Z14574 NOZZLE, #245 2K-47269 ADAPTER 3/8IN QUICK CON A 2O-302931 NOZZLE 1 W 2O-Z15341 REGULATED ELEC.
  • Page 30 EXPLODED VIEW Main Assy Model: WVU-46 Ventless Hood System SK2656 Rev. - 5/24/13 Main Assy...
  • Page 31 RELAY, 120V COIL, SPNO 2E-Z14960 CONTACTOR, 40A N1-Z16862 TERMINAL BLOCK ASSY 2E-44514 RELAY 208-240V COIL 2E-Z15335 TRANSFORMER, 208/240 2M-306719 LOGO WELLS DIECAST SHIELD 2E-305295 SWITCH ROCKER 250V 10A GR 2R-Z14532 CAM LATCH, SLOTTED 2M-Z16744 GRAPHIC PANEL N1-WL0379 CONTROL PANEL DOOR W/ 2J-Z15354...
  • Page 32 NOTE...
  • Page 33 NOTE...
  • Page 34 NOTE...
  • Page 35: Parts & Service

    IMPORTANT: Use only factory authorized service parts and replacement filters. For factory authorized service, or to order factory authorized replacement parts, contact your Wells authorized service agency, or call: Wells Manufacturing 10 Sunnen Dr. St. Louis MO 63143 USA Service Dept.
  • Page 36 WELLS MANUFACTURING 10 Sunnen Dr., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www.wellsbloomfield.com...