If VSIM is ok, check following signals with inserted SIM card:
SIMCLK = 3.25MHz at X386 Pin1
SIMRST = 3VDC at X386 Pin2
SIMDATA at X386 Pin6
If any of the signals above is not measureable, change R388. If the fault persists after changing R388, change UEM D200.