A5 Autofill counter top ib
Trouble shooting
Advanced diagnostics service light warning codes
INDICATOR LIGHT
Green indicator light.
Amber ready light.
Red indicator constantly on.
Red indicator continuously flashing.
Red indicator flashes twice.
Red indicator flashes 3 times.
Red indicator flashes 4 times.
Red indicator flashes 5 times.
Red indicator flashes 6 times.
All lights out.
PROBLEM
Tap is dripping when closed.
Helpline 0870 060 2618
10
6/4/06
4:37 pm
Page 10
CAUSE/PROBLEM
Power on.
Flashes when heating up
On constantly when up to
temperature.
Unit has become scaled up,
and has shut down to prevent
damage to unit.
Lower probe has not been
detected this may be due to
scale build-up.
Upper probe has not been
detected, likely scale build-up.
Unit below 60ºC. Possibly due to
boil dry protection or element
failure.
Thermostat fault. Element is not
heating up.
Water is not going into the unit.
Your unit has accumulated
2000 hours of operation.
Unit may be over boiling.
ACTION
Descale immediately.
(See descale process on page 8.)
Descale unit.
(See descale process on page 8.)
Unit will still operate but needs descaling
ASAP. (See descale process on page 8.)
Check boil dry thermostat has been reset.
Contact Helpline.
Check water pressure, water connection
and that water supply is turned on.
Descale and reset unit.
Water temperature adjustment required.
Contact Helpline.
ACTION
See 'tap failure' guidelines on page 9.
Need help?
Do you have a question about the 76500 and is the answer not in the manual?
Questions and answers