Night Vision Systems CORONAFINDER Operating And Maintenance Manual

Uv viewer

Advertisement

Quick Links

A Division of
www.syntronics.net
OPERATING AND MAINTENANCE MANUAL
CORONAFINDER
UV VIEWER
SYNTRONICS, LLC
Night Vision Systems Division
3500 Shannon Park Drive
Fredericksburg, VA 22408
USA
Telephone and fax: (540) 374-1000
E-mail: nightvision@syntronics.net
Website:
www.syntronics.net
Rev. 10/12/09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CORONAFINDER and is the answer not in the manual?

Questions and answers

Summary of Contents for Night Vision Systems CORONAFINDER

  • Page 1 A Division of www.syntronics.net OPERATING AND MAINTENANCE MANUAL CORONAFINDER UV VIEWER SYNTRONICS, LLC Night Vision Systems Division 3500 Shannon Park Drive Fredericksburg, VA 22408 Telephone and fax: (540) 374-1000 E-mail: nightvision@syntronics.net Website: www.syntronics.net Rev. 10/12/09...
  • Page 2: Table Of Contents

    CONTENTS 1.0 GENERAL DESCRIPTION 2.0 OPTIONS 3.0 SYSTEM SPECIFICATION 3.1. VIEWER CONFIGURATION 3.2 IMAGE INTENSIFIER 3.3 LENS 3.4 FILTERS 3.5 PHYSICAL 3.6 POWER 3.7 ENVIRONMENTAL 4.0 VIEWER OPERATION 4.1 SETUP 4.2 FOCUSING 4.3 EXCESSIVE LIGHT WARNING 4.4 BATTERY REPLACEMENT 4.5 CHANGING FILTERS 4.6 TRIPOD USE 5.0 CAMERA DISASSEMBLY WARRANTY...
  • Page 3: General Description

    The intensifier is a Generation II photocathode powered by a wrap-around high voltage power supply. 2.0 OPTIONS There are many add-on options available for purchase with the CoronaFinder such as a CCD camera, digital camera, camera mounting plate, additional filters, or tripod. 3.0 SYSTEM SPECIFICATION 3.1 VIEWER CONFIGURATION...
  • Page 4: Environmental

    25 g’s, all axes 4.0 VIEWER OPERATION 4.1 SETUP 1. Make sure the ultraviolet lens and a filter are attached to the CoronaFinder. *****CAUTION: DO NOT OPERATE THE VIEWER***** UNLESS THE LENS AND FILTER ARE ATTACHED! 2. Start out with the lens closed to the smallest aperture, F/16.
  • Page 5: Battery Replacement

    Syntronics, LLC Night Vision Systems Division 4.4 BATTERY REPLACEMENT The viewer is powered by two AA alkaline batteries. To replace the batteries, remove the viewer handle by unscrewing the big screw on the underside of the viewer. Unscrew the silver knob below the lens to reveal the battery compartment.
  • Page 6: Tripod Use

    Syntronics, LLC Night Vision Systems Division 4.6 TRIPOD USE Remove the viewer handle by unscrewing the big screw on the underside of the viewer. On the underside of the viewer is a ¼-20 mounting hole that may be used to mount the viewer to any tripod.
  • Page 7: Warranty

    Syntronics, LLC Night Vision Systems Division WARRANTY Syntronics, LLC, warrants the equipment to be manufactured free from defects in material or workmanship. Any part or parts will be repaired or replaced when proven by Syntronics’ examination to have been defective within one year from the date of acceptance by the original purchaser.
  • Page 8: Addendum (Attaching A Digital Camera)

    Note: Since the camera is now on “manual focus”, the focus ring on the eyepiece might need to be adjusted for best possible focus. Also, once the camera is attached to the CoronaFinder, the lens manual focus ring can be rotated slightly to change focus.
  • Page 9 ADDENDUM (CORONA FILTER #1 & #4) INTRODUCTION The CoronaFinder is extremely easy to use. The CoronaFinder is supplied with two filters, Corona Filter #1 and Corona Filter #4. The CoronaFinder must NEVER be operated without one of the Corona Filters installed. Although either Corona Filter may be used, the following will give some guidelines about when to use #1 or #4.
  • Page 10 One may be able to see the corona but still cannot tell exactly where it is. With practice the operator will be able to view the corona, and then lift the CoronaFinder to see the location.

Table of Contents