8.18.1 Exit Delay Termination
(default = enabled) The control panel can reduce the Exit Delay to 7 seconds when an Entry Delay zone is
opened and closed during the delay.
Enable option [4] in the desired section:
Partition 1: [3122] Partition 3: [3322] Partition 5: [3522] Partition 7: [3722]
Partition 2: [3222] Partition 4: [3422] Partition 6: [3622] Partition 8: [3822]
8.18.2 No Exit Delay on Remote Arm
(default = enabled) When a user arms by using a remote control from the Magellan Wireless System (MG-
RTX3), the control panel will cancel the Exit Delay and immediately arm the partition. Enable option [8] in the
desired section:
Partition 1: [3125] Partition 3: [3325] Partition 5: [3525] Partition 7: [3725]
Partition 2: [3225] Partition 4: [3425] Partition 6: [3625] Partition 8: [3825]
8.18.3 Special Arming Exit Delay
(default = 060) This allows to set an exit delay in seconds for a special arming. Special arming are any arming
that do happen without interacting with a keypad (i.e.: scheduled arming, keyswitch arming, WinLoad arming,
no movement arming, etc.)
Partition 1: [3130] Partition 3: [3330] Partition 5: [3530] Partition 7: [3730]
Partition 2: [3230] Partition 4: [3430] Partition 6: [3630] Partition 8: [3830]
8.19 Keypad Lock-out Feature
(default = 005) If a consecutive number of invalid codes are entered into a keypad, the control panel can be set
to lockout access from all the keypads in the partition for a specified period. Program the number of
consecutive invalid codes from 001 to 255 (000 = disabled) into the desired section:
Partition 1: [3105] Partition 3: [3305] Partition 5: [3505] Partition 7: [3705]
Partition 2: [3205] Partition 4: [3405] Partition 6: [3605] Partition 8: [3805]
(default = 015) Program the duration of the keypad lockout from 001 to 255 minutes into the desired section.
Programming 000 into these sections will not lockout the keypad, the control panel will transmit the Keypad
Lockout report code programmed in section
Partition 1: [3106] Partition 3: [3306] Partition 5: [3506] Partition 7: [3706]
Partition 2: [3206] Partition 4: [3406] Partition 6: [3606] Partition 8: [3806]
8.20 Bell Squawk
The control panel can activate the bell output briefly causing the bell or siren to squawk to alert users that a
partition is being armed, disarmed or that an Entry or Exit Delay was triggered. Enable or disable the desired
option (off = disabled):
Partition 1: [3124] Partition 3: [3324] Partition 5: [3524] Partition 7: [3724]
Partition 2: [3224] Partition 4: [3424] Partition 6: [3624] Partition 8: [3824]
Option
Bell Squawk on:
[1]
Disarming
[2]
Arming
EVO Installation Guide
[3937]
Description
Emits 2 squawks upon disarming
(default = disabled)
Emits 1 squawk upon arming
(default = disabled)
.