PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION
INSTALLATION MANUAL
This manual gives detailed advice for installation and should be read carefully
prior to fitting any unvented unit.
This OSO cylinder must be installed by a competent person and be installed in
compliance with the OSO Installation and Maintenance Instructions, all current
legislation, codes of practice and regulations governing the installation of
unvented hot water cylinders in force at the date of installation.
Components supplied with the unit for site fitting
(See also page 2 for component list)
Multibloc valve, includes pressure reducing valve, line strainer, balanced cold water take off,
*
(for shower or bidet only) check and expansion valve.
Tundish
*
1/2''F x 15 x 15 tee piece.
*
Flexible hose.
*
3/4'' x 22mm Elbow / Drain Cock.
*
Commissioning valve, 1/2'' BSP male.
*
Motorised valve.
*
2 x 1/2'' BSP male solar sensor pockets.
*
Components factory fitted
Immersion heater.
*
Thermostats / thermal cut-out.
*
Temperature and pressure relief valve.
*
Installation details
The OSO unvented unit is designed for use with supply pressure up to 16 bar. For pressures over
16 bar an additional pressure reducing valve must be fitted in the supply pipe to the unit.
SOLARCYL
Health and Safety
Manual Handling Operations Regulations 1992 defines
manual handling as: "any transporting or supporting of
a load (including the lifting, putting down, pushing,
pulling, carrying or moving thereof) by hand or bodily
force". The Regulations set no specific requirements
such as weight limits. However common sense still has
to be used based on an ergonomic approach for each
individual.
DIMENSION AND WEIGHTS TABLE 1
CAPACITY LITRES
HEIGHT
1400
DIAMETER
WEIGHT EMPTY
MAX WEIGHT FULL
COIL RATING KW
UPPER COIL
LOWER COIL
-1-
IM/SC2
210
250
330
1600
2090
580
580
580
60
64
82
261
303
397
12
12
18
12
26
26