Do you have a question about the evos and is the answer not in the manual?

Questions and answers

Christina Tu
February 26, 2025

I have a few 1st generation AMG EVOS microscopes and need help on How to replace light bulb? Many thanks!

User image 67bf8f8078f64
1 comments:
Mr. Anderson
February 26, 2025

The 1st generation AMG EVOS microscope does not use mercury arc lamps or traditional light bulbs. Instead, it uses an LED illumination source built into an optical cube. Since the LED is integrated, there is no need to replace any light bulbs, and no maintenance is required for the illumination system.

This answer is automatically generated

Summary of Contents for AMG evos

  • Page 1 Digital Inverted Microscope User Guide 18421 Bothell-Everett Hwy. The Microcsope Evolved. Suite 150 Mill Creek, WA 98012 Phone: (866) 614-4022 or (425) 368-0444 Fax: (425) 368-0555 E-mail: info@amgmicro.com Web: www.amgmicro.com...
  • Page 2: Table Of Contents

    Mechanical Stage Operation ..................................9 Secure Digital (SD™) Card ...................................9 Image Capture Button....................................10 Micron(EVOS) via USB Connection ...............................11 Installing Micron(EVOS) Software ..............................11 Installing Driver ......................................11 Working With DnG Files in Micron(EVOS) ............................12 lCD Positioning ......................................12 maintenanCe 13–14 ..................................lCD Screen Care ......................................13 Objective lens Care.....................................13...
  • Page 3: General Information

    , using correct lifting techniques. • Do not exchange objectives between microscopes unless you know that the components have all been approved and recommended by AMG. • If liquid spills on the microscope, turn off the power immediately and wipe dry.
  • Page 4: Plain Stage Components

    Positioning Knob Condenser assembly Phase annuli Select Wheel Image Capture Button Coarse Positioning Y-axis Fine Positioning X-axis Fine Positioning Focus Control Power Cord Power Switch Objective Select Wheel Dimmer adjustable Rubber Feet (4) eVos™ User Guide amgmicro.com...
  • Page 5: Specifications

    11.8 Kg (26 Lb.) - PLAIN STAGE Weight 13.6 Kg (30 Lb.) - MECHANICAL STAGE Storage Device/Output Secure Digital (SD™) card or USB2 connection to PC Software Micron(EVOS) imaging software (included) AC Adapter; Input 100-240V, 50-60Hz, 0.5A; Power Supply Output 12 VDC...
  • Page 6: Assembly

    Figure 1 staGe plate assembly  plain staGe (Figure 1)  The PLAIN STAGE assembly is pre-installed and pre-positioned at AMG. Simply install the circular stage plate  into the round opening in the  .. stage Figure 2 meCHaniCal staGe (Figures 2 &...
  • Page 7: Objective Lens Assembly

    (Figure 2 - MECHANICAL STAGE)  The color-coded objectives match the color-coding label on the objective turret. When properly installed, EVOS will “know” which objective is in place and adjust the lighting and image capture parameters to suit.  Carefully remove the...
  • Page 8: Operation

     rotates. learning function EVOS microscopes are equipped with a memory function that remembers the last automatic or manual illumination setting that was used for each individual objective, even after being powered off. As the objectives are switched, illumination values return to the last set levels for each objective.
  • Page 9: Objective Select Wheel

    Rotate as necessary to adjust focus of the specimen on screen. Note: Every EVOS microscope has a safety feature that incorporates a “slip-clutch” mechanism to protect the objectives. When the objective turret reaches the end of its travel range, the clutch makes a “clicking”...
  • Page 10: Mechanical Stage Operation

    (see figure 3) into the slot until it clicks and the card locks into position. Figure 3 Remove the card by pressing it down to release it from the slot.  Note: Do not remove SD card until “STORING: EVOS____.DNG” clears from the LCD screen eVos™ User Guide amgmicro.com...
  • Page 11: Image Capture Button

     control. “StORInG:EVOS0000.DnG” display will flash on the LCD screen beneath the SD card slot for about 3 seconds to indicate that EVOS is saving the image onto the memory card. to saVe an imaGe on a pC Via miCron(eVos):...
  • Page 12: Micron(Evos) Via Usb Connection

     The USB connection port allows images to be viewed, captured, saved,  edited, and analyzed directly on a PC via a USB2 cable (included) with AMG’s Micron(EVOS) imaging software (included)  important! Install the software before attaching the microscope to PC.
  • Page 13: Working With Dng Files In Micron(Evos)

    Figure 1 DNG (Digital Negative) files saved on the SD™ card using EVOS can be opened in Micron(EVOS) or other Adobe imaging applications (for installation procedures, see Installing Micron(EVOS) Software on page 11).
  • Page 14: Maintenance

    When moving Mechanical Stage microscopes, be sure to lock the stage with the stage lock pin to prevent the stage from sliding around. Note: To protect all optical components of the microscope, use the dust cover (included) when the microscope is not in use. eVos™ User Guide amgmicro.com...
  • Page 15: Firmware Update

    Update Figure 1 to Update firmware: Download the latest EVOS firmware onto an SD™ card from the AMG web site. Turn power OFF. Insert the SD card into the card slot.   PrESS AND hOLD the Firmware Update Button (LEFT) w hile turning the power ON (see Figure 1).
  • Page 16: Parts & Accessories

    Vessel Holder for T-flasks; any other objective besides those Olympus objectives listed below holds two 25cm flasks, aMEP-Vh005 will void AMG’s warranty support for your EVOS microscope. with rectangular or triangular Olympus Optics. objectives, olympus Vessel Holder for Nunc T-75 Flask;...
  • Page 17: Customer Service

    EVOS™ microscopes are warranted to be free of all defects in material and workmanship for a period of 60 months (5 years) from the date of delivery. The warranty does not apply to any instrument which has...
  • Page 18 Doc Control Number ZP-PKG-0397 REV D2 © 2008 Advanced Microscopy Group, Inc. All rights reserved.