Christina Tu
February 26, 2025
I have a few 1st generation AMG EVOS microscopes and need help on How to replace light bulb? Many thanks!
1 comments:
Mr. Anderson
February 26, 2025
The 1st generation AMG EVOS microscope does not use mercury arc lamps or traditional light bulbs. Instead, it uses an LED illumination source built into an optical cube. Since the LED is integrated, there is no need to replace any light bulbs, and no maintenance is required for the illumination system.
Page 1
Digital Inverted Microscope User Guide 18421 Bothell-Everett Hwy. The Microcsope Evolved. Suite 150 Mill Creek, WA 98012 Phone: (866) 614-4022 or (425) 368-0444 Fax: (425) 368-0555 E-mail: info@amgmicro.com Web: www.amgmicro.com...
, using correct lifting techniques. • Do not exchange objectives between microscopes unless you know that the components have all been approved and recommended by AMG. • If liquid spills on the microscope, turn off the power immediately and wipe dry.
Figure 1 staGe plate assembly plain staGe (Figure 1) The PLAIN STAGE assembly is pre-installed and pre-positioned at AMG. Simply install the circular stage plate into the round opening in the .. stage Figure 2 meCHaniCal staGe (Figures 2 &...
(Figure 2 - MECHANICAL STAGE) The color-coded objectives match the color-coding label on the objective turret. When properly installed, EVOS will “know” which objective is in place and adjust the lighting and image capture parameters to suit. Carefully remove the...
rotates. learning function EVOS microscopes are equipped with a memory function that remembers the last automatic or manual illumination setting that was used for each individual objective, even after being powered off. As the objectives are switched, illumination values return to the last set levels for each objective.
Rotate as necessary to adjust focus of the specimen on screen. Note: Every EVOS microscope has a safety feature that incorporates a “slip-clutch” mechanism to protect the objectives. When the objective turret reaches the end of its travel range, the clutch makes a “clicking”...
(see figure 3) into the slot until it clicks and the card locks into position. Figure 3 Remove the card by pressing it down to release it from the slot. Note: Do not remove SD card until “STORING: EVOS____.DNG” clears from the LCD screen eVos™ User Guide amgmicro.com...
control. “StORInG:EVOS0000.DnG” display will flash on the LCD screen beneath the SD card slot for about 3 seconds to indicate that EVOS is saving the image onto the memory card. to saVe an imaGe on a pC Via miCron(eVos):...
The USB connection port allows images to be viewed, captured, saved, edited, and analyzed directly on a PC via a USB2 cable (included) with AMG’s Micron(EVOS) imaging software (included) important! Install the software before attaching the microscope to PC.
Figure 1 DNG (Digital Negative) files saved on the SD™ card using EVOS can be opened in Micron(EVOS) or other Adobe imaging applications (for installation procedures, see Installing Micron(EVOS) Software on page 11).
When moving Mechanical Stage microscopes, be sure to lock the stage with the stage lock pin to prevent the stage from sliding around. Note: To protect all optical components of the microscope, use the dust cover (included) when the microscope is not in use. eVos™ User Guide amgmicro.com...
Update Figure 1 to Update firmware: Download the latest EVOS firmware onto an SD™ card from the AMG web site. Turn power OFF. Insert the SD card into the card slot. PrESS AND hOLD the Firmware Update Button (LEFT) w hile turning the power ON (see Figure 1).
Vessel Holder for T-flasks; any other objective besides those Olympus objectives listed below holds two 25cm flasks, aMEP-Vh005 will void AMG’s warranty support for your EVOS microscope. with rectangular or triangular Olympus Optics. objectives, olympus Vessel Holder for Nunc T-75 Flask;...
EVOS™ microscopes are warranted to be free of all defects in material and workmanship for a period of 60 months (5 years) from the date of delivery. The warranty does not apply to any instrument which has...
Need help?
Do you have a question about the evos and is the answer not in the manual?
Questions and answers
I have a few 1st generation AMG EVOS microscopes and need help on How to replace light bulb? Many thanks!
The 1st generation AMG EVOS microscope does not use mercury arc lamps or traditional light bulbs. Instead, it uses an LED illumination source built into an optical cube. Since the LED is integrated, there is no need to replace any light bulbs, and no maintenance is required for the illumination system.
This answer is automatically generated