Linak DL12 User Manual
Hide thumbs Also See for DL12:

Advertisement

U S E R M A N U A L
DL12, DB12, DL14,
DB14, DL17 system
with CBD4, CBD5 or CBD6
To learn more about LINAK, please visit:
W W W . L I N A K . C O M
Page 1 of 36

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DL12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Linak DL12

  • Page 1 U S E R M A N U A L DL12, DB12, DL14, DB14, DL17 system with CBD4, CBD5 or CBD6 To learn more about LINAK, please visit: W W W . L I N A K . C O M Page 1 of 36...
  • Page 2 Page 2 of 36...
  • Page 3: Table Of Contents

    Mounting guidelines for the DL14 system ..................11 Mounting top ..........................11 Mounting foot ..........................13 Mounting guidelines for the column DL12 ..................14 Mounting top ..........................14 Mounting foot ..........................14 Mounting guidelines for the column DL17 ..................15 Mounting top ..........................
  • Page 4: Preface

    LINAK subsidiaries and distributors all over the world have authorised service centres, which are always ready to help you. LINAK provides a warranty on all its products. This warranty, however, is subject to correct use in accordance with the specifications, maintenance being done correctly and any repairs being carried out at a service centre, which is authorised to repair LINAK products.
  • Page 5: Important Information

    Important information Important information on LINAK products can be found under the ® following headings: Warning! Failure to comply with these instructions may result in accidents involving serious personal injury. Failing to follow these instructions can result in the product being damaged or being destroyed.
  • Page 6: Before Installation, Reinstallation Or Troubleshooting

    • Make sure that the voltage at the control box is correct before the system is connected to the mains. • System connection. The individual parts must be connected before the control box is connected to the mains. See the User Manual for LINAK actuators, if necessary. During operation: •...
  • Page 7: Only For Eu Markets

    Only for EU markets This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
  • Page 8: Repairs

    Repairs In order to avoid the risk of malfunction, all DESKLINE repairs must only be carried out by authorised LINAK ® workshops or repairers, as special tools must be used and special gaskets must be fitted. Lifting units under warranty must also be returned to authorised LINAK workshops.
  • Page 9: Misc. On The Deskline ® System

    (see label). LINAK A/S warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with. Furthermore, the system must not be exposed to violent treatment. In the event of this, the warranty will be ineffective/invalid.
  • Page 10: Description Of The Deskline

    Exceeding the duty cycle will result in a dramatic reduction of the life of the system. The DB/DL system range contains following products: • 1 control box CBD4/CBD5/CBD6 • DL12, DB12, DL14, DB14 or DL17 (1 - 4) • 1 exchangeable mains cable • motor cables (1 - 4) •...
  • Page 11: Mounting Guidelines For The Dl14 System

    Mounting guidelines for the DL14 system Mounting top The top of the column is supplied with 4 M6 threaded holes meant for mounting onto the desk frame. We advise you to fasten the desk frame by means of 4 pcs. M6 screws of a good quality (min. 8.8) and of a suitable length, which must not go further than max.
  • Page 12 As the desktop amplifies the sound, we advise you to place a vibration/shock absorbing material between the desktop and the desk frame. (Example of how to mount a 2-parallel DESKLINE DL system) ® LINAK recommends that the DESKLINE DL system should be used in push applications. ® Page 12 of 36...
  • Page 13: Mounting Foot

    Mounting guidelines for the column DL14 Mounting foot The DL14 is supplied with 4 M6 threaded holes and 2 M8 screws for mounting of the foot. You can either use 2 M8 screws or 4 M6 screws dependent on your foot design. We advise you to use screws of a good quality min.
  • Page 14: Mounting Guidelines For The Column Dl12

    Mounting foot The top of the column is supplied with 4 x M6 The DL12 is supplied with 4 x M6 threaded holes. threaded holes meant for mounting onto the desk We advise you to use screws of a good quality min.
  • Page 15: Mounting Guidelines For The Column Dl17

    MC 6 Mounting guidelines for the column DL17 Mounting top Mounting foot The top of the column is supplied with 4 x MG The DL17 is supplied with 4 x MG threaded holes and threaded holes meant for mounting onto the desk 2 x M8 screws for mounting of the foot.
  • Page 16: Mounting Guidelines For Db12 And Db14

    Mounting guidelines for DB12 and DB14 For detailed information on how to mount the DB12 or the DB14, please contact LINAK A/S. The top of the motor is supplied with holes for the self-tapping special screws.These screws together with the 2 rubber washers are supplied with the DB12/DB14.
  • Page 17 For detailed information on how to mount the DB12/DB14, please contact LINAK A/S. From the factory, the DB12/DB14 is delivered with the hollow spindle driven into end position. Please observe that the solid spindle may roll out during transportation/handling, but it must be rolled back to end position before mounting in the profile.
  • Page 18: Mounting Guidelines For The Cbd4/Cbd5/Cbd6S

    Mounting guidelines CBD4/CBD5/CBD6 The control box is to be fastened with 4 screws (3 screws for the CBD5 and theCBD6) with a head diameter between ø 8 and ø 10 mm. Out of regard for the surface tension ø 10 mm is preferable due to lower surface tension.
  • Page 19: Electrical Connection Of The Db/Dl System

    The earth connection does not protect other electrical products. CBD4/CBD5 with mains cut-off (non ZERO models) If the power cable is damaged it has to be replaced by an authorized LINAK service centre to avoid any danger. Hook for cable relief...
  • Page 20: Initialisation Of The Deskline Parallel System

    Initialisation of the DESKLINE parallel system The DESKLINE system is initialised by pressing the down button once or twice and holding it down until the DB/DL runs into end stop. It will then automatically run approx. 5 mm out again and hereafter slowly run in again.
  • Page 21: Anti-Collision Tm

    Anti-Collision™ The function (anti-collision) is an option for the standard CBD4/CBD5/CBD6 advanced/control box software 0077432 version 1.66 and later. A system with anti-collision can limit material damages on a desk if a collision with a solid object should occur. Enabling the anti-collision To enable the anti-collision function a little plug called a dongle must be mounted in one of the 2 control ports.
  • Page 22: Piezo Tm : Description Of The Feature

    PIEZO™: description of the feature For optimised safety against squeezing and blocking on a desk, LINAK has developed the DBs and columns with an integrated sensor, called PIEZO. The option minimises the risk for damages on a desk caused by squeezing or blocking of obstacles in up and down direction.
  • Page 23: Accessories And Repair

    Accessories Please contact your nearest LINAK dealer for information. Repairs Systems should only be repaired by an authorised LINAK service centre or an engineer. Systems to be repaired under warranty must be sent to an authorised LINAK service centre. Warning! By unauthorised opening of the system there is a risk that it may malfunction at a later date.
  • Page 24: Disposal Of Linak Products

    Disposal of LINAK products As LINAK customers often ask us how our products can be disposed of or scrapped, we have prepared this guidance that enables a classification to different waste fractions for recycling or combustion. Guidance We recommend that our products be disassembled as much as possible and divided into different waste groups for recycling or combustion.
  • Page 25: Labels

    Label for DB12 Label for DL12 Label for DL17 Label for DB14 Label for DL14 Label for CBD4 Label for CBD5 Label for CBD6 Page 25 of 36...
  • Page 26 LINAK shall be responsible solely that LINAK products comply with the specifications set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specific LINAK product can be used for the application in question.
  • Page 27: Drawing Appendix

    DRAWING APPENDIX DL12 1178 1205 wing No.: 0639097 wing No.: 0639097 518 3.5 545 3.5 Page 27 of 36...
  • Page 28 DL14 Page 28 of 36...
  • Page 29 DL17 No.: 0639080 No.: 0639080 +6.5 1178 -4.5 518 3.5 Page 29 of 36...
  • Page 30 DB12 Nominal lenght 500 3 mm Minimum lenght retracted at max. load 496 3 mm DB14 Page 30 of 36...
  • Page 31 CBD4 CBD5 Page 31 of 36...
  • Page 32 CBD6 Page 32 of 36...
  • Page 33: Declaration Of Conformity

    Page 33 of 36...
  • Page 34 Page 34 of 36...
  • Page 35 Page 35 of 36...
  • Page 36: Addresses

    +65 6844 0070 correct and actual status of said information on its products. E-mail: servodynamics@servo.com.sg COLOMBIA While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the www.servo.com.sg MEM Ltda same reasons as mentioned above, guarantee the availability of any...