Alpha OKU Instructions For Installation, Use And Maintenance Manual

Solar heating for swimming pools

Advertisement

OKU SOLAR HEATING FOR SWIMMING POOLS
ALPHA -
Introduction
Solar heating for swimming pools with OKU-Absorbers normally will be oper ated with a dir ect circuit.
The water from the pool will be pumped dir ectly through the abs orbers. You don´t have to interpose a
heat exchanger.
Different configurations of OKU sw imming pool solar heat ing
1. Operation with filter pump via three-way motor ball valve with
difference-temperature regulation
This configuration can usually be selected if the absorbers are not to
be set up higher than 6 m abov e the surface of the water. The three-
way motor ball valve is integrated into the pr essure line of the filter
installation. Because of the difference-temperature regulation the ball
valve is changed ov er when the abs orber temperature is higher than
the temperature of the water of the swimming pool. The f ilter stream
is then pumped thr ough the abs orbers. The warmed water flows
back into the filter circuit by way of a Tee.
2. Operation with own pump an difference temperature regulation
integrated into the filter circuit
In many cases it may be sensible or even necessary to install a
separate pump for the solar heating. For example when the deliv ery
head from the water level to the absorber panel is more than 6 m.
The water is diverted from the filter installation by way of a Tee and
pumped thr ough the abs orbers by the auxiliary pump. This pump is
switched by the difference-temperature regulation to ens ure that it
only runs to actually win energy. The filter and solar pump are
separately regulated. It is usually advisable to integr ate non-return
valves in both the solar and the filter circuit.
3. Operation with own pump and dif ference-temperature regulation -
piping independent of filter circuit
This configuration is chosen when the f ilter piping is difficult of
access. The water is sucked out of the swimming pool by an
immersion pipe, pumped thr ough the abs orbers, and the warmed
water is conducted back into the swimming pool. Her e too the
difference temperature regulation ens ures that the pump only r uns
to win energy. If the pump is mounted abov e the water level and the
delivery head is more than 5 m, a non- return valve should be
incorporated.
1) OKU-Abs orber
2) Difference-temperature regul ation OE 1
3) Filter installation
4) Solar circuit forward and return
The water of the swimming pool c an flow through the oku absorbers in either direction, so they can be
mounted both lengthwis e and side by side. The indiv idual rows of absorbers are connected on a Tichelmann
mounted both lengthwis e and side by side. The indiv idual rows of absorbers are connected on a Tichelmann
principle (same routes for each row). It is not advisable to connect more than ten abs orbers in series.
Instruction for installation an operating
5) Three-way motor bal l valve
6) Temperature s ensor, absorbers
7) Temperature s ensor, swimming pool
8) Vent valve
9) Stop cock (downdraft brak e)
10) Drain cock
11) Pump for s olar circuit
12) Non-return v alve

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OKU and is the answer not in the manual?

Questions and answers

Summary of Contents for Alpha OKU

  • Page 1 12) Non-return v alve The water of the swimming pool c an flow through the oku absorbers in either direction, so they can be mounted both lengthwis e and side by side. The indiv idual rows of absorbers are connected on a Tichelmann mounted both lengthwis e and side by side.
  • Page 2 This example represents a system with 16 OKU abs orbers in 4 lines at 4 items. Depending on the s ize of your swimming pool and the ar ea available for the absorbers numerous other schemes of installation are also possible.
  • Page 3 If further connections ar required to connect the absorbers in series only the cap has to be cut off. 2. Place the OKU-Absorbers on the designated areas in the arrangement that is desired and connect them with hos e connections and hose saddles according with the the scheme of connection.
  • Page 4 Additionally you c an close the cover cap of the vent valve. Operating the system in winter OKU-Absorbers are frost resistant. Due to the pipes the system must be emptied in winter nevertheless. Usually systems which emptied when they´ re switched off, don´t need any precaution.
  • Page 5 How to fasten on a pant iles tiled roof 1. Hook for pantiles tiled roof Art.N° 3212 2. Screw-in pipe clamp 1/2" zinc plated with a gum inlay Ar t.N° 3213 3. Perforated tape zinc plated 12 x 1 Ar t.N° 3210 with a s crew 5 x 16 Art.N° 3211 1000 1000 1001...
  • Page 6 How to fasten on a flat roof On a flat roof you have to safe the OKU-Absorbers against the wind. Ther efore you can stretch a wire rope or a perlon-hurry against the absorber field at intervals of circa 2 m and anc hor it on the edge of the roof.
  • Page 7 How to fasten it on a sloping roof (slated roof or cement asbestos roof) The fastening on a s lated or cement asbestos roof is comparable with the fastening on a tiled r oof. But you have to screw-in the ring-screw through the roofing into the foundation. If you have a wooden foundation s crew it into the boar ding or battens.

Table of Contents