1.1 Information on the user guide This translation of the original user guide is an integral part of the WAVE 224 monitor/thin client and provides you with information on the set-up, use, storage and disposal of the device. Before beginning any work, read the user guide and always keep it in an accessible place.
Page 6
General information Copyright notice WAVE 224 monitor/thin client - Industrial monitor/thin client...
Safety notices Safety 2.1 Designated use WAVE 224 monitor/thin client is an HMI PC system. WAVE 224 monitor/ thin client is used to implement control and operating concepts and to display and manipulate information in industrial and commercial envi- ronments.
– Never plug in or unplug the power supply plug when live with voltage. – The supply cable must not be supplied with voltage until assembly has completely finished. WAVE 224 monitor/thin client - Industrial monitor/thin client...
Page 9
– Save your data regularly. – Check the charge capacity regularly. – Don’t allow it to drop below 5%. WAVE 224 monitor/thin client - Industrial monitor/thin client...
The integrated AX3000 MODEL 80 Ultra-Thin-Client offers a user inter- face for data processing purposes. The connection is via Ethernet. Depending on the configuration, two USB interfaces are also provided for additional peripherals. WAVE 224 monitor/thin client - Industrial monitor/thin client...
The product designation and identification will be found on the type plate. This is always located on the rear of the device and contains the following information: Fig. 4: Position of type plate WAVE 224 monitor/thin client - Industrial monitor/thin client...
24" IPS LCD display with LED backlight Display area 531.36 x 298.89 mm Native (maximum) resolution 1920 x 1080 (Full HD) Page ratio 16:9 Colors 16.7 million Brightness 300 cd/m Contrast 3000:1 Response time 25 ms WAVE 224 monitor/thin client - Industrial monitor/thin client...
Page 14
2 x USB, 1 x Ethernet All the installed USB components (VoIP hardware, touchscreen, keyboard, WLAN, etc.) are connected to the WAVE 224 monitor/thin client using only one connector (type Power supply / consumption Extra-low voltage power supply 12 ‒ 24 V DC, 10 ‒ 5 A Protection of supply lead (Extra-low max.
0 °C ‒ +40 °C Humidity 10 % ‒ 90 %; non condensing Maße (in mm ohne Tastaturgelenk) Width Height Depth Weight Net weight ca. 12 kg 3.4 Dimensions Fig. 6: Dimensions of front of device WAVE 224 monitor/thin client - Industrial monitor/thin client...
Page 16
Product description Dimensions Fig. 7: Dimensions of back of device Fig. 8: Dimensions in side view WAVE 224 monitor/thin client - Industrial monitor/thin client...
= 24-pole DVI socket for connecting to the basic computer Fig. 11: DVI socket with pinout HDMI port = 19-pole HDMI socket for connecting to the basic computer Fig. 12: HDMI socket with pinout WAVE 224 monitor/thin client - Industrial monitor/thin client...
Page 18
Risk of material damage if the device is connected to an incorrect power supply. Connecting the device to an incorrect power supply may cause material damage. – Check the power rating of your device. WAVE 224 monitor/thin client - Industrial monitor/thin client...
Page 19
(100 – 240 V AC, 50 – 60 Hz) GF-7,62. The corresponding plug carries the designation Phoenix Con- tact PC 4/ 3-ST-7,62. Fig. 17: 3-pole Phoenix Contact socket for the power supply Designation Significance Surge protectors Phase Neutral conductor WAVE 224 monitor/thin client - Industrial monitor/thin client...
Make sure the ambient temperature does not exceed the specified maximum value (see Ä Chapter 3.3 “Technical data for the device” on page 13). When installing the equipment also observe Ä Chapter 3.4 “Dimen- sions” on page 15. WAVE 224 monitor/thin client - Industrial monitor/thin client...
Working on heavy equipment may lead to serious injuries. – Always have two people when working with heavy equipment. Hold the WAVE 224 monitor/thin client firmly so that it is level with the equipment rack adapter. WAVE 224 monitor/thin client - Industrial monitor/thin client...
Page 23
Ä Chapter 3.5 “External connectors” on page 17 – and the requirement for the electrical supply lead Ä Chapter 3.3 “Technical data for the device” on page 13. WAVE 224 monitor/thin client - Industrial monitor/thin client...
Page 24
Starting up Mounting the device Fig. 18: Interface plate on the rear of the WAVE 224 monitor/thin client (depending on the configuration) Connect up all the cables between the interface plate and the equipment rack adapter. Tighten the screws on the mains plug.
5.1 Switching the device on Fig. 20: ON/OFF button for switching on and off Press the ON/OFF button between the dummy plugs on the left- hand side of the WAVE 224 monitor/thin client. ð The system goes into operation. 5.2 Switching the device off NOTICE! Loss of data due to failure to save it.
Regularly clean the surface of the device using a soft, moist, lint- free cloth. For more significant soiling: Use isopropanol as cleaning agent. Note the information in the following chemical resistance data: WAVE 224 monitor/thin client - Industrial monitor/thin client...
The WLAN antenna together with the WLAN USB stick are located in the equipment rack adapter. The WLAN USB stick may be connected only directly to a USB interface with no interposed USB hub. WAVE 224 monitor/thin client - Industrial monitor/thin client...
Page 30
Operation Setting up the WLAN (optional) Install the WLAN driver from the supplied USB stick. ð The WLAN is set up. WAVE 224 monitor/thin client - Industrial monitor/thin client...
(see Ä Chapter 5.2 “Switching the device off” on page 25). The device is defective. Send an e‑mail to support@systec-hardware.com or Fill out a support form at http://www.systec-hardware.com/de/hardware-support.html. WAVE 224 monitor/thin client - Industrial monitor/thin client...
Working on live equipment may give rise to material damage. – Before you carry out any work on a device: Disconnect it from the power supply. You will need the following tools: Allan key (4) for M5 x 16 WAVE 224 monitor/thin client - Industrial monitor/thin client...
Page 34
Lift the device off the equipment rack adapter and hold it firmly. ð You can now see the interface plate on the rear of the device. Fig. 22: Interface plate on the rear of the WAVE 224 monitor/thin client (depending on the configuration) Release the screws on the mains plug.
Avoid mechanical vibration and shocks. Avoid cold weather and extreme temperature fluctuations. Pay attention to the information in the “Technical data” section. Ä Chapter 3.3 “Technical data for the device” on page 13 WAVE 224 monitor/thin client - Industrial monitor/thin client...
Pay attention to the information in the “Technical data” section. When the consignment is delivered, immediately check it for possible transport damage and deal appropriately with any detected transport damage or non-obvious defects. WAVE 224 monitor/thin client - Industrial monitor/thin client...
Page 38
Packaging and transport Transporting the device WAVE 224 monitor/thin client - Industrial monitor/thin client...
Systec-Services GmbH for proper dis- posal. Do not dispose of the equipment via your local municipal col- lection centers. Under the WEEE Directive these may be used only for privately used equipment. WAVE 224 monitor/thin client - Industrial monitor/thin client...