KOBE Brillia RAX2130SQB-1 (30”) Installation Instructions And Operation Manual

KOBE Brillia RAX2130SQB-1 (30”) Installation Instructions And Operation Manual

Kobe brillia series range hoods

Advertisement

KOBE Range Hoods
Brillia Series
Model No.
RAX2130SQB-1 (30")
RAX2136SQB-1 (36")
RAX2142SQB-1 (42")
RAX2130SQB-WM-1 (30")
RAX2136SQB-WM-1 (36")
RAX2142SQB-WM-1 (42")
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Brillia RAX2130SQB-1 (30”) and is the answer not in the manual?

Questions and answers

Summary of Contents for KOBE Brillia RAX2130SQB-1 (30”)

  • Page 1 KOBE Range Hoods Brillia Series Model No. RAX2130SQB-1 (30”) RAX2136SQB-1 (36”) RAX2142SQB-1 (42”) RAX2130SQB-WM-1 (30”) RAX2136SQB-WM-1 (36”) RAX2142SQB-WM-1 (42”) INSTALLATION INSTRUCTIONS AND OPERATION MANUAL...
  • Page 2 1. DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL. 2. Have your original invoice as proof of purchase and product serial number ready. 3. Call 1-877-BUY-KOBE (289-5623); or e-mail to info@koberangehoods.com to report the problem. NO RETURN, NO REFUND, NO EXCHANGE IF: 1.
  • Page 3: Table Of Contents

    [ENGLISH] - READ AND SAVE THESE INSTRUCTIONS - CONTENTS IMPORTANT SAFETY INSTRUCTIONS ..................1 COMPONENTS OF PACKAGE....................3 INSTALLATION .......................... 5 OPERATING INSTRUCTIONS....................11 MAINTENANCE ........................12 SPECIFICATIONS ........................13 MEASUREMENTS & DIAGRAMS .....................14 PARTS LIST ..........................16 CIRCUIT DIAGRAM ........................20 TROUBLE SHOOTING ......................21 WARRANTY ..........................22 PRODUCT REGISTRATION .....................24 - READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING -...
  • Page 4: Important Safety Instructions

    KOBE RANGE HOODS authorized agents will automatically void the warranty. KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.
  • Page 5 What to Do In The Event Of a Range Top Grease Fire • SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911.
  • Page 6: Components Of Package

    3 (36” & 42”hood) {E} 6” Round Plastic Collar – 1 For the operation manual, please refer to our website: KOBERangehoods.com * Pre-installed * Pre-installed FOR MORE INFORMATION, PLEASE VISIT OUR W EBSITE www.KOBERangeHoods.com CONTACT KOBE RANGE HOODS AT (626) 775-8880.
  • Page 7 {G} Duct Cover – 1 {H} Screws Package – 1 For the operation manual, please refer to our website: KOBERangehoods.com * Pre-installed * Pre-installed 3/16 “x 3/8” (8PCS) FOR MORE INFORMATION, PLEASE VISIT OUR W EBSITE www.KOBERangeHoods.com CONTACT KOBE RANGE HOODS AT (626) 775-8880.
  • Page 8: Installation

    INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to TABLE 1. (All calculation in inches.) - FOR UNDER THE CABINET - TABLE 1 Cabinet A = Height of Floor to Ceiling B = Height of Floor to Counter Top Hood (Standard: 36") C = Preferred Height of Counter Top...
  • Page 9: Safety Warning

    SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR. Installation Contents UNDER THE CABINET WALL MOUNT...
  • Page 10: Under Cabinet Installation

    UNDER CABINET INSTALLATION For Model No.: RAX2130SQB-1 / RAX2136SQB-1 / RAX2142SQB-1 Figure 1 Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. (Figure 1) A straight, short vent run will allow the hood to perform more efficiently.
  • Page 11 Figure 5 Ductwork Installation 5. Use steel pipe to connect the 6” round plastic collar {E} on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 6 Wiring to Power Supply THIS RANGE HOOD MUST BE PROPERLY GROUNDED.
  • Page 12: Wall Mount Installation

    WALL MOUNT INSTALLATION For Model No.: RAX2130SQB-WM-1 / RAX2136SQB-WM-1 / RAX2142SQB-WM-1 Figure 8 Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. Refer to Figure 8. A straight, short venting run will allow the hood to perform more efficiently.
  • Page 13 Figure 12 Wiring to Power Supply THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY QUALIFIED ELECTRICIAN IN ACCORDANCE WITH APPLICABLE NATIONAL LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.
  • Page 14: Operating Instructions

    OPERATING INSTRUCTIONS For RAX21-SQB-1 or RAX21-SQB-WM-1 Series Model No.: RAX2130SQB-1 / RAX2136SQB-1 / RAX2142SQB-1 RAX2130SQB-WM-1 / RAX2136SQB-WM-1 / RAX2142SQB-WM-1 Note: For best results, turn fan on prior to any preparation or cooking and keep fans running while cooking. Adjust speed as needed. To operate the fan function •...
  • Page 15: Maintenance

    MAINTENANCE For optimal performance, clean the range hood surface and baffles regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve its fine appearance. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2.
  • Page 16: Specifications

    SPECIFICATIONS MODEL / SIZE For Under Cabinet Application: RAX2130SQB-1 (30”) ; RAX2136SQB-1 (36”) ; RAX2142SQB-1 (42”) For Wall Mount Application: RAX2130SQB-WM-1 (30”) ; RAX2136SQB-WM-1 (36”) ; RAX2142SQB-WM-1 (42”) COLOR 18-Gauge Commercial Grade Stainless Steel CONSUMPTION / AMPERE 300W / 2.5A NUMBER OF BLOWER DESIGN Seamless / Satin Finish...
  • Page 17: Measurements & Diagrams

    MEASUREMENTS & DIAGRAMS ***All inch measurements are converted from millimeters. Inch measurements are estimated. ***All measurements in ( ) are millimeters. -FOR UNDER THE CABINET- MODEL NO.: RAX2130SQB-1 (30”) / RAX2136SQB-1 (36”) / RAX2142SQB-1 (42”) - FOR WALL MOUNT - MODEL NO.: RAX2130SQB-WM-1 (30”) / RAX2136SQB-WM-1 (36”) / RAX2142SQB-WM-1 (42”)
  • Page 18 ***Hood-Mounting Bracket ***Duct Cover-Mounting Bracket...
  • Page 19: Parts List

    PARTS LIST MODEL NO.: RAX2130SQB-1 (30”) RAX2136SQB-1 (36”) RAX2142SQB-1 (42”) DESCRIPTION MODEL /SIZE PART NO. 6” Round Plastic Exhaust L1-0505-0003 Hood-Mounting Bracket L1-0201-03900 10-2130B RAX2130SQB –WM-1 RAX2136SQB –WM-1 10-2136B Hood Casing RAX2142SQB-WM-1 10-2142B Capacitor L1-0401-0120-24 L1-04012-D001 LED Light Driver RAX2130SQB-WM-1 B101-2130B-06 RAX2136SQB-WM-1 B101-2136B-06...
  • Page 21 MODEL NO.: RAX2130SQB-WM-1 (30”) RAX2136SQB-WM-1 (36”) RAX2142SQB-WM-1 (42”) DESCRIPTION MODEL /SIZE PART NO. Duct Cover-Mounting Bracket L1-0203-1630 Duct Cover B102-21900 6” Round Plastic Exhaust L1-0505-0002 Hood-Mounting Bracket L1-0201-03900 RAX2130SQB-WM-1 10-2130B RAX2136SQB-WM-1 10-2136B Hood Casing RAX2142SQB-WM-1 10-2142B Capacitor L1-0401-0120-24 LED Light Driver L1-04012-D001 B101-2130B-06 RAX2130SQB-WM-1...
  • Page 23: Circuit Diagram

    CIRCUIT DIAGRAM MODEL NO.: RAX2130SQB-1 (30”) / RAX2136SQB-1 (36”) / RAX2142SQB-1 (42”) RAX2130SQB-WM-1 (30”) / RAX2136SQB-WM-1 (36”) / RAX2142SQB-WM-1 (42”)
  • Page 24: Trouble Shooting

    TROUBLE SHOOTING Issue Possible Cause Solution After The power is not on. Make sure the circuit breaker and the unit’s Installation, power is ON. Use a voltage meter to check the both motors power supply. and lights are The wire connection is not secure. Check and tighten wire connection.
  • Page 25: Warranty

    TWO-YEAR LIMITED WARRANTY FOR PARTS AND LABOR ON KOBE PREMIUM / BRILLIA SERIES: For two years from the date of your original invoice from a KOBE authorized dealer, we will, at our sole discretion, choose to repair or replace the product free of charge that failed due to manufacturing defects.
  • Page 26 3. Have the model number 4. Have the serial number 5. Have a description of the nature of any defect in the product or part TO REQUEST WARRANTY SERVICE, PLEASE CONTACT THE KOBE RANGE HOODS SERVICE CENTER: KOBE SERVICE CENTER (USA ONLY)
  • Page 27: Product Registration

    1. Date of purchase 2. Model No. 3. Serial No. For warranty service or spare parts purchase contact: KOBE Service Center (USA ONLY) Toll Free: 1-855-800-KOBE (5623) Email: kobe@adcoservice.com For service in Canada and to report a problem, please...
  • Page 28 Arcadia, CA 91006 USA www.KOBERangeHoods.com This KOBE hood is made for use in the USA and CANADA only. We do not recommend using this hood overseas as the power supply may not be compatible and may violate the electrical code of that country. Using a KOBE hood overseas is at your own risk and will void your warranty.