OPERATIONS
Timer Adjustment - Timer Models only
Isolate the power supply. Replace front cover BEFORE switching on the power supply.
The timer is factory set at midpoint. Time is set by placing the black bridge over 2 of the
pins on the right hand side of the timer board. If bridge is not fitted, timer will default to
20 minute setting. Replacement bridges are available from Silavent.
30 Mins
HUMIDITY ADJUSTMENT - HUMIDITY MODELS ONLY
Isolate the power supply. Replace the front cover and the humidity control adjustment
position is clearly marked. Turn clockwise for less sensitivity and anti-clockwise for more
sensitivity. Turn fully clockwise to turn the humidity sensor off. Replace front cover
BEFORE switching on the fan.
SVC 100 RANGE
SVC100B Standard SVC100PB
With Pull Cord
With
With Humidistat
SVC100TB
SVC100HTB
Timer
and Timer
CLEANING
Disconnect power supply before cleaning. It is important to clean fans annually as regular cleaning helps
maintain performance and ensure safe, reliable operation.
The front cover shutter can be removed from the fan and gently dusted with a soft brush or washed in
warm water with dishwashing liquid. Dry carefully before refitting.
IMPORTANT : Make sure that the shutter thermoactuator on the fan chassis is fully withdrawn (i.e. cold)
before fitting the front cover shutter.
The interior of the fan can be dusted with a soft brush. Do not use water.
On humidity control models, please ensure that no water enters the sensor grille.
For window fitting, the SDF901WFK window kit is required.
230v AC - 50Hz
15W
Single Speed IPX4 Rating – This product is double insulated.
Manufactured in the UK by
Polypipe
Sandall Stones Road, Kirk Sandall Industrial Estate, Kirk Sandall, Doncaster DN3 1QR
Tel: +44 (0) 8443 715523 Fax: +44 (0) 8443 715524
www.polypipe.com/ventilation