    1.3.3 External Battery Installation: .........................3 1. 3.4 The Cautions For Connection: ......................3 1.4 ISDK-616 System Connection Figure ......................4 1.5 F0601 ISDK-616 CPU Card Connecting Instruction: .................5 1.6 F0658 DSP Card ............................5 1.7 F0638 TRK/STA Card (TRK3/STA8) ......................6 1.8 F0610 Multi-Function Card .........................6 1.9 F0611 Doorphone Voice Card ........................7...
  • Page 3: System Specifications And Installation

    1. SYSTEM SPECIFICATIONS AND INSTALLATION 1.1 System Specifications MODEL ISDK-616 Power Source DC 30V/ 2A Power Consumption (except stations) 24V/4 – 50AH External Back-up Battery Max. Battery Charge Current 27. 6V/0.3A Station Capacity 8– 18 3 – 6 CO Lines 8 –...
  • Page 4: F0610 Multi-Function Card

    1 Loop 3 wires 1.3 KSU Installation Instructions 1.3.1 ISDK-616 KSU installation steps: 1.3.1.1 To turn the AC Power or battery switch to “OFF” 1.3.1.2 Make sure the power supply is 100V or 260V or else please install the constant voltage regulator if the voltage exceed the voltage range.
  • Page 5: Choose Main Power Supply

    1.3.2 Choose Main Power Supply: 1.3.2.1 Please avoid using the same power supply socket for main power and heavy load power supply. 1.3.2.2 Please make sure the AC power supply is 100V-260V please install the constant voltage regulator if the voltage exceed the voltage range. 1.3.3 External Battery Installation: 1.3.3.1 The external battery is auto rechargeable and the recharge voltage is 27.6V.
  • Page 6: Isdk-616 System Connection Figure

    1.4 ISDK-616 System Connection Figure power switch power input F0601 CPU hole 1 2 3 4 F0638 TRK/STA card output hole of cable Basic Equipment: Position A: Install F0658 DSP card on P5 of F0601 CPU card. Position B: Install F0638 (TRK/STA Card).
  • Page 7: F0601 Isdk-616 Cpu Card Connecting Instruction

    1.5 F0601 ISDK-616 CPU Card Connecting Instruction: power switch power input hole F0601 CPU Battery 1 2 3 Remarks: 1. P5 is connecting F0658 (DSP card) to CPU card (F0601). 2. P1,P2 are connecting F0610 (Multi-function card) or F0611 (Doorphone Voice card).
  • Page 8: F0638 Trk/Sta Card (Trk3/Sta8)

    1.7 F0638 TRK/STA Card (TRK3/STA8) Remark: 1. P1 is connecting F0601 (CPU card) 2. P2, P3, P5 is the Trunk socket 3. P2, P3, P5 is the station socket, each socket for 1 digital phone. 1.8 F0610 Multi-Function Card P1 : may connect with 2 single line ------------- telephones (analog phones) or -PT2...
  • Page 9: F0611 Doorphone Voice Card

    Connection of RS-232 One way simple metering Computer System Two ways connection One way simple metering with handshake RS-232 25 Pins 9 Pins 25 Pins 9 Pins 25 Pins 9 Pins ― ― ― GND(2) → → → TXD(3) ← RXD(4) ←...
  • Page 10: Programming Guide

    2. PROGRAMMING GUIDE 2.1 PROGRAMMING INSTRUCTION After installing the ISDK system, please proceed the following steps for the first programming. DIP-Switch LED of CPU blinks ON Press HOLD Enter Programming  Switch the    1, 2, 3, 4 ON and OFF repeatedly twice in 1 sec.
  • Page 11: The Meaning Of Each Function Key For Programming

    2.3.1 The meaning of each function key for programming PAGE TRAN Copy Delete Copy To confirm and copy this unit to all trunk or station To confirm and copy this of the following unit, press again to the original unit to the next station or physical location.
  • Page 12: System Program : Kind 1

    2.4 SYSTEM PROGRAM : Kind 1 Operation : press [SPKR]  [HOLD] (press twice within one second)  enter [2][6][5][6] or other setting password  enter kind [1] [HOLD]  enter item no. Item Description Default Instruction 0: Null (depends on K1 item1,2,60,95) 1: Only active system auto-day/night transfer (not include the station service class) 2: Only active station day/night transfer...
  • Page 13: Kind 1 (11-22)

    Kind 1 (11-22) Item Description Default Instruction 1-9999 ms For speed dialling, the display "W" (wait) 11 Pause time 1000 means to wait for a while as per the default or the setting time. 0: SEP. 17 THU 09:01 (24-hour system) (Month/Day/Week/Hour:Minute) 1: 17 SEP.
  • Page 14: Kind 1 (23-36)

    Kind 1 (23-36) Item Description Default Instruction 0-9999 seconds 0: No forward When station A calls station B, station B no answers and transfer to its forwarding station 23 Ringing time before call forward after the setting time. Related program: kind 2 item 8-9 0-9999 seconds 0: No stop Ringing time to reserve/queue a busy...
  • Page 15: Kind 1 (37-46)

    Kind 1 (37-46) Item Description Default Instruction Limited /Allow dialing table for 6th class: For outward dialling restriction, match to ….45… International call service class 3 program K7 (Limited/Allow dialling table) LC6=0: setting value: 0-8 0-5: Limited table Limited /Allow dialing table for 7th class: 6-8: Allowed table …..5…...
  • Page 16 Kind 1 (47-59) Item Description Default Instruction 47 Inter-digit time of SLT pulse dialling 10-9999 x 3.333 ms (SLT to PBX) 10-9999 x 3.333 ms The shortest time of single line telephone The min. flash time for when the single line flash telephone pressed "HOOK".
  • Page 17: Kind 1 (60-73)

    Kind 1 (60-73) Item Description Default Instruction 0: Null (depends on K1 item1,2,60,95) 1: Only active system auto-day/night transfer (not include the station service class) 2: Only active station day/night transfer 3: Auto day/night transfer for system & station service class Relatives programs: Kind 1 item 58,59 60 Day/Night transfer type for holiday The priority:...
  • Page 18: Kind 1 (72-88)

    85 Internal dialling tone volume 00-63 scales Internal dialling tone volume of off-hook 00-63 scales dialling Must be adopt Uniphone handsfree keyphone Internal dialling tone volume of on-hook 00-63 scales dialling Must be adopt Uniphone handsfree keyphone Delete the repeated storing number of...
  • Page 19: Kind 1 (89-106)

    Kind 1 (89-106) Item Description Default Instruction 89 Select to use RS-232C interface 0: F0610 0:Auto-return to IDLE after active the queuing function, it will notify the queuing station as 91 Reserve/Queuing way soon as the communication ended 1:keep on waiting till the communication end and ringing directly.
  • Page 20: Kind 1 (47-59)

    Kind 1 (107-121) Item Description Default Instruction Unmarked some prefix called number 0~31 digits digits of the selection on SMDR printing Suitable for printing the simple countering at hotel. It can mark some dialling digits of the Some last digits of the called number mark telephone number selection on SMDR printing 0: according to the setup of busy forwarding...
  • Page 21: Kind 1 (122-135)

    Kind 1 (122-135) Item Description Default Instruction 0: Not allowed 123 Whether allows printing the DND status 1: Allowed 0:$TO:04/07/07 20 22 01 1234567 0000 03:11:04 00012 00000 1:$TO:04/07/07 20 22 011234567 0000 03:11:37 00:00:10 2:$TO:04/07/07 20 22 V016 1234567 0000 03:12:22 00008 00000 3:$TO:04/07/07 20 22 V016 1234567 0000 03:13:02 00012 00000 Change the printed time mode of the 4:$TO:04/07/07 20 22 T001 1234567 0000 03:13:54 00011 00000...
  • Page 22: Kind 1 (141-143)

    Kind 1 (141-143) Item Description Default Instruction Switch Music on hold of built-in DSP This setting become invalid if there’s self-record 0123456 (DISA) music on hold 0: Chinese 143 Switch the alarm language 01234567 1: English...
  • Page 23: Station Line Program : Kind 2

    2.5 STATION LINE PROGRAM : Kind 2 Operation : press [SPKR]  [HOLD] (press twice within one second)  enter [2][6][5][6] or other setting password  enter programming kind [2]  [HOLD]  enter station line no.  [HOLD]  enter programming item no.
  • Page 24: Built-In Disa (Dsp) : Kind 9

    2.12 Built-In DISA (DSP) : Kind 9 Operation : press [SPKR]  [HOLD] (press twice within one second)  enter [2][6][5][6] or other setting password  enter programming kind [9]  [HOLD]  display doorphone no.  [HOLD]  enter programming item no. ITEM DESCRIPTION INSTRUCTION...
  • Page 25: Kind 9 (149-52)

    Kind 9 (149-52) ITEM DESCRIPTION INSTRUCTION DEFAULT Station number for fax machine Assigned station number for receiving a fax Waiting code 0~9, *, # or no waiting code (**=cancel) Waiting time after press the waiting (transfer times) x (this item value) code Ex.
  • Page 26: Setting Item Of Working Mode (00-05)

    Setting item of working mode (00-05) SUB-ITEM INSTRUCTION Day Night Noon Special 1 Special 2 DESCRIPTION Operator code 0~9, *, # or none digital code Inquiry code 0~9, *, # or none digital code Dial to extension directly (00) Not allowed (01) Allowed (02) Allowed and announce “station no.”...
  • Page 27: Setting Item Of Working Mode (06-10)

    Setting item of working mode (06-10) SUB-ITEM INSTRUCTION Day Night Noon Special 1 Special 2 DESCRIPTION Transfer mode after (00) After voice announce, if did voice announce not dial again, the CO line will “Station No Answer”. be cut off. (01) After voice announce, if did not dial again, the CO line will transfer to the last dialed station.
  • Page 28 Programming for doorphone unit (Single line port) ***** Please use Uniphone DHU unit to make sure its normal working ****** Basic programming: Ext.36 Kind 2-128=1 (Incoming call mode= voice call directly for doorphone unit) Ext.36 Kind 2-39=00 (Day class= hot line, kind 2 item 46- > K02/K03 set execute function) Or Kind 2-39=01 (Day class=city call, can dial directly) Ext.36...
  • Page 29 Ext.36 kind 2, item 112 = 248 (doorphone calls used ringing tone) kind 2, item 113 = 248 Ext.36 kind 2, item 122 = 1 (can hear warning tone) Ext.36 kind 3, item 123 = 1 (have warning tone when calls to busy operator) Ext.36 kind 2, item 7 = 1, (External electric lock can change the message of open...
  • Page 30 Station void no. Sorry! The number you dial can not be recognized. You can dial announce another extension number or dial "9" to the operator. Operator busy Sorry! The operator is busy. Please dial another extension announce number. (If you need to wait, please dial #) or dial "9" to the operator.