Mitsubishi Electric MJ-E14EG-S1-IT Service Manual page 32

Table of Contents

Advertisement

Operation Checks
When the side of the move sensor assembly is
held and rotated left and right about 60 degrees
(a total of 120 degrees), the fan must move
smoothly in sync.
When louvre N is held and rotated by hand, it
must operate smoothly with no unusual noises.
At the upward position (until the top casing is
slanted), the louvre CY-N must open.
The louvre CY-N top edge must be at the parting
position at the stop position.
The louvre CY-2 front edge must be at the
difference position at the stop position.
The louvre CY-3 front edge must be at the
stopper position at the stop position.
Louvre CY-1, CY-2, and CY-3 must have no
gaps.
<Precautions for Assembly>
• When the move sensor assembly side is held and rotated left and right 60° (a total of 120°), adjust
the length of the sensor lead wires so that they do not become taut, and secure with tape.
32
Give them some slack
Filament tape
Gear holder
Louvre CY-N
Rotate left
and right 60°
MOVE EYE
Left and right 60°
Rotate up and down
Difference position
Stopper position
Parting position