Setting to detect needle position (for 12 needles)
It is necessary to store value of needle selection sensor
according to number of needles. If this setting is not made,
normal needle selection may not be made.
1. Pressing "MENU" button on control box, turn power on.
(Press till you get display of SYSTEM OK)
2. Set moving head manually to the 1st needle.
3. Press "MENU" button.
4. Press "
" button and press "ENT" button with display
of
Other.
5. Press "
" button and press "ENT" button with display
of
Mainte.
6. Press "
" button to Input Code to make it
[2251], then press "ENT" button.
7. Press "
" button and press "ENT" button with display
of
Machin.
8. Press "
" button to get No: D, Press "ENT" button
with display of D to store value of sensor at the 1st needle.
9. Press "
" button and press "ENT" button with display
of
Ret.
10. Set moving head manually to the 12th needle.