17.3. Self Diagnosis Function

• The display screen of wireless remote control unit and the self-diagnosis LEDs (green) on the outdoor printed circuit board in the
outdoor unit can be used to identify the location of the problem.
Refer to the table below to identify and solve the cause of the problem, and then re-start the air conditioner system.
• If the problem is solved and operation returns to normal.
LED 1 illuminates and others LED are off.
Diagnosis
Abnormality
display
or
LED 6 LED 5 LED 4 LED 3 LED 2 LED 1
protection
control
H11
Indoor/outdoor
abnormal
communication
H12
Indoor unit
capacity
unmatched
H14
Indoor intake
air temperature
sensor
abnormality
H15
Compressor
temperature
sensor
abnormality
H16
Outdoor
current
transformer
(CT)
abnormality
H19
Indoor fan
motor
merchanism
lock
H23
Indoor heat
exchanger
temperature
sensor
abnormality
H27
Outdoor air
temperature
sensor
abnormality
H28
Outdoor heat
exchanger
temperature
sensor 1
abnormality
H32
Outdoor heat
exchanger
temperature
sensor 2
abnormality
Abnormality
Protection
judgement
operation
After
Indoor fan only
operation for
operation can
1 minute
start by
entering into
force cooling
operation
90s after
power supply
Continuous
for 5s
Continuous
for 5s
Continuous
happen for 7
times
Continuous
for 5s
Continuous
for 5s
Continuous
for 5s
Continuous
for 5s
50
Problem
Check location
Indoor/outdoor
• Indoor/outdoor
communication not
wire terminal
establish
• Indoor/outdoor
PCB
• Indoor/outdoor
connection wire
Total indoor
• Indoor/outdoor
capability more than
connection wire
maximum limit or
• Indoor/outdoor
less than minimum
PCB
limit, or number of
• Specification and
indoor unit less than
combination table
two.
in catalogue
Indoor intake air
• Indoor intake air
temperature sensor
temperature
open or short circuit
sensor lead wire
and connector
Compressor
• Compressor
temperature sensor
temperature
open or short circuit
sensor lead wire
and connector
Current transformer
• Outdoor PCB
faulty or compressor
faulty or
faulty
compressor
faulty
Indoor fan motor lock
• Fan motor lead
or feedback
wire and
abnormal
connector
• Fan motor lock or
block
Indoor heat
• Indoor heat
exchanger
exchanger
temperature sensor
temperature
open or short circuit
sensor lead wire
and connector
Outdoor air
• Outdoor air
temperature sensor
temperature
open or short circuit
sensor lead wire
and connector
Outdoor heat
• Outdoor heat
exchanger
exchanger
temperature sensor 1
temperature
open or short circuit
sensor 1 lead
wire and
connector
Outdoor heat
• Outdoor heat
exchanger
exchanger
temperature sensor 2
temperature
open or short circuit
sensor 2 lead
wire and
connector