  • Page 1 Space Saver Installation and User Guide Discover the hidden benefits Space Saver...
  • Page 2 Installation Guide Index Installation Guide Hydronic SS3 W SS5 W SS7 W SS9 W Hydronic Low Voltage SS5 W/12V Hydronic/Electric SS5 W/Dual SS5 W/Dual Electric SS2E W User Guide Hydronic & Hydronic Low Voltage SS3 W SS5 W SS7 W SS9 W SS5 W/12V SS5 W/12V...
  • Page 3 SS3 W, SS5 W, SS7 W, SS9 W The following items should be included in the carton: Product complete with fixed white grille and pre-wired mains cable. Fixing screws (2). One pair flexible installation hoses (not included with SS3 models). Overlay grilles which fit over the fixed white grille are available in different colours and finishes.
  • Page 4 Installation Guide We recommend the use of a kneepad when installing this product. Cut the opening in the plinth to the size shown in the table. Use method A or B Model Width A Height B* SS3 W 475mm 96mm SS5 W 475mm 96mm...
  • Page 5 Commissioning Turn on the electrical supply at the fused spur. upper switch to RED — the fan should run and heat will flow within a few minutes. Set the upper control switch on the fascia grille to BLUE and lower switch to either I or II. The Balance the central heating system if Space fan will run.
  • Page 6 Installation Guide Heat Output Performance It is recommended that the Space Saver model chosen is capable of maintaining the calculated heat loss at normal heat output (I) enabling the boost setting (II) to be used for faster heat up. Model Heat Output ∆...
  • Page 7 SS5 W/12V The following items should be included in the carton: Product with fixed white grille. Transformer with 450mm of pre-wired mains cable. Two single-pin male connectors. Fixing screws (2). One pair flexible installation hoses. Overlay grilles which fit over the fixed white grille are available in different colours and finishes. Please consult the price list for details.
  • Page 8 Installation Guide We recommend the use of a kneepad when installing this product. Cut the opening in the plinth to the size shown in the table. Use method A or B. Model Width A Height B* SS5 W/12V 475mm 96mm * The overall height of the grille is 100mm.
  • Page 9 Isolate electrical supply and connect the transformer flying leads to the fused spur (3A). The transformer must be located outside the bathroom or high humidity area. Connect single-pin male connectors to the twin core cable you have supplied. Push in the connectors to the transformer terminals and connect the other end of the cable to the terminals on the back of the product.
  • Page 10 Installation Guide Position heater, making sure the flexible hoses are not kinked and the electrical cable is not snagged. 7b. Fix fascia grille to plinth. 7a. Fit overlay grille (if supplied) over fixed grille. Heat Output Performance It is recommended that the Space Saver model chosen is capable of maintaining the calculated heat loss at normal heat output (I) enabling the boost setting (II) to be used for faster heat up.
  • Page 11 Fault Finding 1. Fan does not run on any switch setting. a. Check the power supply is switched ON. b. Check fuse in the fused spur. c. Check the wiring connections at the fused spur. d. Check connections at the transformers and product.
  • Page 12 Installation Guide Space Saver is primarily intended for installation heater will automatically stop in the event of the in the space beneath kitchen cupboards behind heating element reaching the cut out temperature. the plinth. However, it can also be installed in To ensure adequate airflow, a minimum clearance similar applications such as stair risers and other of 20mm between the top of the product and any...
  • Page 13 Fit isolating valves (not supplied) to the system flow and return pipes. Failure to fit isolating valves may mean that the product is not serviceable in the event of failure. Connect the flexible hoses between the system pipework and heater. Open the isolating valves and check for leaks.
  • Page 14 Installation Guide Commissioning Turn on the electrical supply at the fused spur. Set the upper rocker switch to the left (red), the middle rocker switch to the left (hydronic Set the upper rocker switch on the fascia grille heating) and the lower switch to the left to the right (blue) and the lower switch to the (normal output).
  • Page 15 Heat Output Performance - Hydronic Model It is recommended that the Space Saver model chosen is capable of maintaining the calculated heat loss at normal heat output (I) enabling the boost setting (II) to be used for faster heat up. Model Heat Output ∆...
  • Page 16 Installation Guide SS2E W The following items should be included in the carton: Product complete with fixed white grille and pre-wired mains cable. Fixing screws (2). Overlay grilles which fit over the fixed white grille are available in different colours and finishes. Please consult the price list for details.
  • Page 17 Isolate the electrical supply and connect the heater electric cable to the 10A fused spur. The fused spur must not be directly above the heater, but should be accessible after completion of the installation. Commissioning Turn on the electrical supply at the fused spur. Set the lower 2kW switch to ON —...
  • Page 18: User Information

    User Guide SS3 W, SS5 W, SS7 W, SS9 W & SS5 W/12V User Information Your product is covered by a free 5-year parts and labour guarantee; please complete and return the Guarantee Registration Card to us as soon as possible to ensure that should you require assistance, we can help you quickly and more efficiently.
  • Page 19 Air Circulation (summer use) Fault Finding This Space Saver is covered by a free 5-year parts Ensure your central heating system is off. Set the and labour guarantee. Please refer to the Fault upper switch to BLUE and the lower switch to I or II.
  • Page 20: Hydronic Heating

    User Guide Hydronic Heating Fault Finding This Space Saver is covered by a free 5-year parts Ensure your central heating system is on. Check and labour guarantee. Please refer to the Fault the upper rocker switch is to the left (red), the middle rocker switch to the left (hydronic Finding section on page 15 for advice.
  • Page 21 SS2E W User Information Your product is covered by a free 5-year parts and labour guarantee; please complete and return the Guarantee Registration Card to us as soon as possible to ensure that should you require assistance, we can help you quickly and more efficiently. Heating Before switching the heater on, please ensure the FAN ON...
  • Page 22 Accessory Remote Room Thermostat Location Select a location well away from any heat, sunlight or draughts that may affect the performance of the thermostat. Locations adjacent to doors or windows must be avoided. Recommended height is 1.5m above floor level. Fixing •...
  • Page 24 Smith’s Environmental Products Ltd, Blackall Industrial Estate, South Woodham Ferrers, Chelmsford, Essex, CM3 5UW Tel: 01245 324900 Fax: 01245 324422 Sales E-mail: sales@smiths-env.com General Information E-mail: info@smiths-env.com Web: www: smiths-env.com For the Republic of Ireland, contact MT Agencies (Ireland) Ltd on Tel: 01 844 3212 As part of the policy of continuous product improvement, 0109 04-0250...