Smart temp SMT-200 rev3 Owner's Manual

Smart temp smt-200 rev3

Advertisement

Quick Links

SMT-200
Owner's Manual – Installation and Operating Instructions
Please read this manual carefully before installation and use.
Index
Installation Instructions
Wiring Connections
DIP switch Configuration
External Sensor Connection (option)
Operating Manual
Technician Settings
Model SMT-200 Rev3 Smart Temp Aust. 12/7/2007
Smart Temp Australia Pty Ltd
Unit 20, 1488 Ferntree Gully Road
Knoxfield Victoria 3180
Tel (03) 9763 0094
www.smarttemp.com.au
rev3
www.smarttemp.com.au
1
2
3
4
5
6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMT-200 rev3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Smart temp SMT-200 rev3

  • Page 1 Owner’s Manual – Installation and Operating Instructions Please read this manual carefully before installation and use. Index Installation Instructions Wiring Connections DIP switch Configuration External Sensor Connection (option) Operating Manual Technician Settings Model SMT-200 Rev3 Smart Temp Aust. 12/7/2007 www.smarttemp.com.au...
  • Page 2 1. Installation Instructions Separate the front panel from back panel by depressing the tongue located in the top of the unit. Pull the back panel out. Line the back panel up against the wall or flat surface. Install three screws as required. Make electrical connections as shown on enclosed electrical wiring diagram.
  • Page 3 3. DIP switch configuration Location of DIP switches: DIP switches Factory default configuration for DIP switches: 1 2 3 4 5 6 1 2 3 4 5 6 Table 3.1 – DIP switch selection DIP switch S1: Cool only or All Func.
  • Page 4 The length of the cable for the external sensor is 30 meters with standard cable. If longer distance is required then shielded cable must be used. There is a wide range of sensors for different applications, duct, room, etc. For further details contact Smart Temp (03) 9763 0094 or www.smarttemp.com.au 5. Operating Manual 5.1 On/Off...
  • Page 5 6. Technician Settings 6.1 Setting temperature limits and offset • Press and hold the “ON” button (5 second) – “50” will appear on display. • Using the (+) button set the number to “55”. Settimg Cool limit • Press the ON button again - “COOL” will appear on display. •...
  • Page 6 6.3 Door contact input This input is normally open, can be used to connect door switch or window contact, etc. The contact is Voltage free (2 terminals), normally open (activates when closed). If the door contact closes the thermostat has two options (DIP switch selectable): •...