Eight cell one hour charger

Advertisement

Quick Links

MH-C801D
Eight Cell One Hour Charger
Thank you for purchasing the PowerEx MH-C801D
battery charger. Read these instructions carefully and
thoroughly before operating this unit. IMPORTANT
SAFETY INSTRUCTIONS. READ AND SAVE THESE
INSTRUCTIONS.

GENERAL PRECAUTIONS

Do not charge battery cells other than NiMH or NiCD. AA Batteries
must be able to accept a 2.0A (Rapid mode) / 1.0A (Soft mode) rapid
charge current. AAA Batteries must be able to accept a 0.7A (Rapid) /
0.35A (Soft) rapid charge current.
Do not use one-hour rapid charge mode on AA batteries rated under
2000mAh and AAA batteries under 700mAh. To charge them, use the
Soft Charging mode (refer to "Soft Charging Mode").
Do not expose the unit to rain or moisture due to the risk of fire.
Do not operate the charger if it appears damaged in any way.
Always place the battery cells with positive tip facing the top. Incorrect
polarity may cause fire or explosion. Observe polarity diagrams located
on the charger.
Do not allow the unit to be exposed to direct sunlight. Operate in well-
ventilated area.
Do not allow the battery terminals to become shorted.
To reduce the risk of damage to the power cord, always pull by
connector rather than the cord.
FEATURES & SPECIFICATIONS
Eight independent charging slots. Charges 1-8 AA or AAA batteries.
Selectable Rapid Charge and Soft Charge mode.
Recharges in approximately 1 hour.
Selectable conditioning / rejuvenation cycle.
Worldwide power supply.
Rapid Charge Current:
Microprocessor:
Charge Time*:
Input Voltage:
* Charge time will vary depending upon the brand, capacity, and
condition of batteries being charged.
PRINTED IN TAIWAN A03-3713353-438
2.0A (AA), 0.7A (AAA)
Eighth-generation MH-NM7008 Powerex
Precision Microprocessor
60 Minute (Rapid), 120 Minute (Soft)
AC 100-240V 50-60Hz
This section explains various charging modes and when to use them. To
enable each mode, refer to the "Operation" section.
Rapid Charge Mode (Default)
Shortest recharging time (approximately one hour).
Suitable for AA batteries with capacity greater than 2000mAh and
AAA with capacity greater than 700mAh.
Soft Charging Mode
Maximizes battery life and performance (recharging time
approximately two hours).
Suitable for most batteries.
Recommended if recharging time is not critical.
Conditioning Mode
A special mode which rejuvenates and cycles batteries. Applies a
special initial charge, discharge and recharge cycle which
restores battery performance (requires up to 14 hours to
complete).
Conditioning cycle can be used to rescue degraded batteries and
exercise infrequently-used batteries.
Recommended once every ten normal charges for NiMH batteries
to ensure performance.
Rapid Charge Mode (Default)
1.
Connect the supplied power cord to the power supply unit and connect
to a compatible outlet (100-240VAC, 50/60Hz). Connect the DIN
connector to the charger unit as shown in the figure below.
TIP: When operating the charger outside of its intended region of use,
simply obtain a power cord with a suitable plug type or use a plug-
changer. Transformer is not necessary.
VARIOUS MODES
OPERATION

Advertisement

loading
Need help?

Need help?

Do you have a question about the MH-C801D and is the answer not in the manual?

Questions and answers

Summary of Contents for Powerex MH-C801D

  • Page 1: General Precautions

    MH-C801D Eight Cell One Hour Charger Thank you for purchasing the PowerEx MH-C801D VARIOUS MODES battery charger. Read these instructions carefully and thoroughly before operating this unit. IMPORTANT SAFETY INSTRUCTIONS. READ AND SAVE THESE This section explains various charging modes and when to use them. To enable each mode, refer to the “Operation”...
  • Page 2 Insert AA and/or AAA batteries. ALWAYS INSERT THE BATTERIES Soft Charging Mode FROM LEFT TO RIGHT LEAVING NO EMPTY SLOT. NOTE: Soft Charging is activated for all battery slots simultaneously and For best performance, group batteries of similar charge and/or type cannot be activated for each individual battery.