Page 2
Complete Comfort P286-1600 Loaded with features, your TotalTouch™ thermostat provides comfort, ease of use in a package that works for you. P286-1600 - all in an easy to use and install True touch screen technology offers application that works in a variety of instal- responsive action, clear and easy to read lations where no common wire is avaliable.
GLOSSARY OF TERMS SELECT A LOCATION Anticipator control – Anticipator control Differential – Differential is defined as Install your TotalTouch™ thermostat approximately 5 feet (1.5 meters) above the floor in is used to turn off the heating equipment the difference between the cut-in and an area with good air circulation.
Page 5
MOUNTING TOTALTOUCH™ TO THE WALL WIRING TABLE Make sure to turn off the power supply located at the electrical service panel. HVAC CONTROL CARD All heating and cooling units should be OFF. Remove the cover plate by pulling up the cover from the left or right side only. Align the thermostat unit to the wall.
Page 6
INSTALLING THE HVAC CONTROL CARD INSTALLING THE HVAC CONTROL CARD ONE AIR CONDITIONER > P286-1600 2 Heating and 1 Cooling for 2 Wire Installation with HVAC ONE AIR CONDITIONER & ONE HEAT Control Card • WIRING THE HVAC CONTROL CARD AT THE EQUIPMENT - CHOOSE YOUR INSTALLATION: FURNACE...
Page 7
INSTALLING THE HVAC CONTROL CARD INSTALLING THE HVAC CONTROL CARD ONE AIR CONDITIONER & TWO HEAT ONE HEAT PUMP FURNACE FURNACE COMPRESSOR 2ND STAGE ONE AIR CONDITIONER & TWO STAGE FURNACE ONE HEAT PUMP & ONE HEAT STAGE 1 STAGE 2 FURNACE COMPRESSOR FURNACE...
Page 8
INSTALLING THE HVAC CONTROL CARD THERMOSTAT AND HVAC CONTROL CARD FURNACE WITH INDEPENDENT 24VAC SOURCE • Then Connect the T1 and T2 to the thermostat You can connect without worry of polarity REMOVE JUMPER SPECIAL FURNACE INDEPENDENT 24VAC SUPPLY...
DIAGNOSTICS HOME PAGE > The P286-1600 was developed with diagnostic tools on board to ensure an easy installation, and to save on steps between the HVAC equipment and the thermostat. • Upon connection if the COMM Indicator Light is steadily lit, it signifies a positive connection.
CONTROL PAGE THERMOSTAT OPERATION MODE > The TotalTouch™ Control Page provides you with an easy and intuitive • Your TotalTouch™ thermostat can run in Program Mode or can hold a fixed screen to set your thermostat- all functions are available at the touch of temperature.
CONTROL PAGE – TEMPERATURE SETPOINTS FAN OPERATION MODE • AUTO, HEAT, COOL AND OFF • There are three modes of fan operation: Fan Auto, Fan On, Fan Off. When the fan is running, the animated fan icon will appear on the Home Page. Based on your HVAC equipment you can quickly and easily select the mode of operation - Automatic •...
MENU PAGE MENU PAGE - DATE AND TIME SETTINGS > To access the Menu Page, simply touch Menu from the Control Page. • Select the 12 or 24 hour clock display. Remember it is as easy as a touch of the button. •...
MENU PAGE - PROGRAM SETTINGS ENERGY WATCH • PROGRAM SETTINGS: This feature easily and quickly programs your • ENERGY WATCH: This unique and patented feature thermostat to fit your needs and lifestyle. Remember by programming the provides a display of system energy consumption and thermostat you can increase energy efficiency and reduce energy.
SCREEN OPTIONS VACATION MODE • CLEAN SCREEN: This function allows you to safely wipe and clean the screen with • VACATION SETTINGS: Allows you to set the temperature to a fixed setpoint during a dampened cloth with out accidentally changing any of the settings; it places the the time you are on vacation, providing energy savings and comfort for your return TotalTouch™...
MENU PAGE MENU PAGE - ADVANCED SETTINGS • FILTER MONITOR: Displays filter usage in days and resets filter timer – when acti- > IMPORTANT INSTALLER SET-UP vated the FILTER MONITOR icon will appear on your HOME PAGE – this feature must This TotalTouch™...
Page 16
ADVANCED SETTINGS – WELCOME ADVANCED SETTINGS – WELCOME HOME BUTTON: Returns you to the Home Page at anytime- remember you will º Choose between display units of Fahrenheit or Celsius for thermostat temperature have to re-enter through the button. ADVANCED SETTINGS SECURITY: The security settings allow you to protect your TotalTouch™...
ADVANCED SETTINGS – CONFIGURING YOUR EQUIPMENT ADVANCED SETTINGS – SETTING THE DIFFERENTIAL > IMPORTANT: BY INADVERTENTLY MODIFYING COMPRESSOR AND > THE P286-1600 ALLOWS YOU TO CONTROL UP TO 2 STAGES OF FURNACE SETTINGS, YOU MAY SERIOUSLY DEGRADE SYSTEM HEATING AND 1 STAGE OF COOLING, DEPENDENT ON THE TYPE OF PERFORMANCE.
ADVANCED SETTINGS – TIMER FEATURE ADVANCED SETTINGS – HEAT PUMP • Specify the number of minutes for which Stage 1 will function until Stage 2 is acti- • HP “ON” when Furnace On: Heat Pump and Furnace can operate together when vated to help raise (or cool) temperature (if the temperature set point is not reached).
ADVANCED SETTINGS – CALIBRATION ADVANCED SETTINGS – CALIBRATION > CALIBRATION OF TEMPERATURE > TEMPERATURE CALIBRATION TABLE Your TotalTouch™ Thermostat is rated for an accuracy of +/-1 degree with temperature • Firstly, determine with a calibrated thermometer the temperature difference – then use the following table to adjust your thermostat.
SIMPLE THERMOSTAT MODE TROUBLESHOOTING Simple Mode has the following basic features: • Touch screen buttons do not function properly. Remove cover, press the reset but- ton located in the bottom left corner then accurately touch 3 target centers on the Temperature Control Modes: screen when prompted.