1. Important safety instructions 1. Important safety instructions Before using the device, be sure to carefully read the Safety Instructions. Keep this document with the device at all times. 2. Approvals Read these instructions. Keep these instructions Heed all warnings. Follow all instructions.
3. Warnings To completely disconnect this equipment from the AC 3.4.3. Radio interference mains, disconnect the power supply cord plug from the AC A sample of this product has been tested and complies with receptacle. The mains plug of the power supply cord shall the limits for the European Electro Magnetic Compatibility remain readily operable.
5. Introduction 5.1. Welcome Thank you for choosing the Lab.gruppen PLM+ Series for your sound reinforcement needs. We are confident that you will be pleased with the performance, unique features, configuration flexibility, reliability, and long-term durability offered by this product.
Carefully open the shipping carton and check for any damage to the device or the supplied accessories. Every Lab.gruppen product is tested and inspected before leaving the factory and should arrive in perfect condition. If any damage is discovered, please notify the shipping company immediately. Only the consignee may initiate a claim with the carrier or their insurers for damage incurred during shipping.
7. Installation 7.2. Mounting PLM+ is made for mounting in 19 inch racks. Four screw holes are available for attachment of the amplifier to the racks front rack rail. This device has no top or bottom vents; therefore, units may be stacked directly on top of one another.
8. Cooling and fan operation 8. Cooling and fan operation PLM+ devices use a forced-air cooling system with airflow from front to rear, allowing high continuous power levels without thermal problems. To facilitate maximum air flow, ensure that no objects such as rack doors or lids are placed at the front or rear of the rack.
9. Operating voltage 9.1. Low voltage country considerations Although the PLM+ Series has a wide range of operating mains voltage, some considerations can be applicable for low voltage regions. PLM+ performs well throughout the specified nominal voltage range but has slightly better efficiency at higher voltages.
10. Grounding 10. Grounding Use correctly-shielded balanced audio input connections to minimize hum and interference. PLM+ Series must be grounded (earthed) with the safety ground pin to the mains distribution system. NEVER disconnect the earth (ground) pin on the mains cable (AC power cord). 11.
Page 12
11. Product overview Mute Enable – Selection of MUTE ENABLE allows dynamic function buttons to operate as Mute controls for the module inputs and power output channels. The MUTE ENABLE button flashes when the mode is selected; a subsequent press deselects the mode. If left activated, MUTE ENABLE mode will automatically disable two minutes after last mute action.
11. Product overview 11.2. Rear panel 1Gbps PRIM 1Gbps 100-240V 2400-2950W SPEAKER OUTPUTS INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 1-2 INPUT 3-4 50-60Hz LINK LINK PLM 2K44 CH 1 CH 3 CH 2 CH 4 PIN 1: SCRN 2: POS 3: NEG ANALOG WITH LOAT AES/EBU...
Page 14
11. Product overview Use the primary connector when using a star network topology, consisting of individual Cat-5e connections between the devices and an Ethernet switch. Alternatively, this connection can be used to daisy chain directly to another Lake Processor. The daisy chain topology should not be used with Dante. For a technical reference of the Ethernet Port, please refer to the full PLM+ Series Operation Manual.
12. Signal flow and processing 12. Signal flow and processing The table below depicts the audio signal flow for a PLM+ device. Module Data stored in Module FIles (Speaker Presets) Frame Data stored in System Files and Frame Presets Attenuator ISVPL Mute Amp Gain...
13. Quick Start Tutorial 13. Quick Start Tutorial This section will describe how to get started with associated software and set up a basic system for operation. 13.1. Network setup 13.1.1. Network connections / topology Each frame has two network ports; a primary and a secondary. See the below diagram for a typical network topology using the primary ports.
13. Quick Start Tutorial 13.2. Software installation and firmware update 13.2.1. Lake Controller software suite 1. The Lake controller software suite includes the Lake controller and accompanying utilities: Lake LoadLibrary and Dante discovery services. Download the Lake Controller installation from www.labgruppen.com. 2.
13. Quick Start Tutorial 13.3. System setup This tutorial provides a step-by-step guide for configuration of a typical professional loudspeaker system and provides an overview of the basic features and operation of the frame. It describes how to configure 4-channel frame for use with a generic 3-way loudspeaker system (with separate HF, MF and LF drivers), plus a separate subwoofer.
Page 19
13. Quick Start Tutorial Bridge Bridge 14. The B module is already a CL1way as default and can be used to drive the sub. 15. Tap Store/Recall EXIT to return to the Modules Menu. 16. Ensuring Module A (or any other module that you want to control) is selected (yellow border), tap I/O Config. 17.
Page 20
13. Quick Start Tutorial Levels Control - Drag sliders and tap mute buttons for module Parametric EQ control – Select filter on the top squares input and output channels. and adjust filter properties by dragging the controls. Sliders at the bottom control center frequency and Q (bandwidth). Gain is controlled in the main window area.
13.4. Rational Power Management™ Rational Power Management™ (RPM) is a unique Lab.gruppen feature that allows for flexible allocation of power across channels of a PLM+. Power that is not used by one output channel is free for use by another output channel with greater demands.
Page 22
13. Quick Start Tutorial Auto RPM: The frame will automatically allocate power per output channel according to the ISVPL settings in the Lake module. If the ISVPL settings taken together allow total output higher than the capabilities of the amplifier, RPM will reduce the ISVPL limiter thresholds evenly based on a proportional reduction in dB.
14. Faults and warnings 14. Faults and warnings Category/Type Name On screen text Description Action FRAME Check network cabling/ Frame unable to find Lake controller Lake Controller offline CTRL OFFLINE network if controller Warning on the network expected on the network Frame not able to lock to Check AES sender and AES clock slipping...
Page 24
14. Faults and warnings Category/Type Name On screen text Description Action The Under Voltage limiter is active as the mains supply is approaching the lower Increase mains distribution Under Voltage Limit UVL ACTIVE end of the device´s operational voltage. stiffness or reduce output Warning Output power is decreased to ensure power to avoid limiting...
Page 25
14. Faults and warnings Category/Type Name On screen text Description Action LoadSmart detected more speakers Check load and More speakers OVR SPKR COUNT Warning than expected cabling or fingerprint Check load and Uncertain about load UNCERTAIN LOAD LoadSmart uncertain about load Warning cabling or fingerprint Perform LoadSmart...
15. Technical Specifications 15. Technical Specifications PLM 12K44 PLM 20K44 General Processing / Network Lake / Dante Lake / Dante Numbers of amplifier channels Total burst power all channels (share among channels with RPM) 12000 W 20000 W Max. Output Power (all ch.’s driven)
Page 27
Intercooler, Class TD and Lake are national and/or international registered trademarks of Lab.gruppen AB. PLM, Powered Loudspeaker Management, R.SMPS, LoadLibrary, LoadSmart, SpeakerSafe, BEL, UVL and ISVPL are trademarks of Lab.gruppen AB. Dolby and the double-D symbol are registered trademarks of Dolby Laboratories. Contour, Mesa Quad EQ, Mesa Parametric EQ, Raised Cosine Equalization, LimiterMax and Iso-Float are trademarks of Dolby Laboratories.
Lab.gruppen dealer. If the product fails to perform as specified during the warranty period, Lab.gruppen will undertake to repair, or at its option, replace this product at no charge to its owner, provided the unit is returned undamaged, shipping prepaid, to an authorized service facility or to the factory.
16. Warranty and support 16.2.2. Factory service In the event a Lab.gruppen product requires factory service, you may contact Lab.gruppen’s service department for return instructions and a Return Authorization number. Please note for product return: 1. Use the original packing.
Need help?
Do you have a question about the PLM 12K44 and is the answer not in the manual?
Questions and answers