Heating installation ............8 3.4.2 Hot water generation........... 9 5.4.1 Cylinder boost.............. 25 3.4.3 ’VR 66’ Control Centre..........9 5.4.2 Party ................25 5.4.3 1 day away from home ..........25 Frost protection function..........9 0020135485_00 VRT 350 Operating instructions...
Warning signs are identified by an upper and lower separ- ating line and are laid out according to the following basic principle: Danger! Type and source of danger Explanation of the type of danger. ▶ Measures for averting the danger. 0020135485_00 VRT 350 Operating instructions...
If you are absent during a frosty spell, ensure that the – Energy-saving operation heating installation remains in operation and the rooms – Maintenance operations are warmed adequately. ▶ Please note the frost protection function. Operating instructions VRT 350 0020135485_00...
Even so, in the event of inappropriate or non-intended use, impairment of the unit and other property may arise. The controller controls a heating installation with a Vaillant heater with eBUS interface in a way that is room-controlled and time-dependent.
You can view the serial number under "Menu → Inform- ation → Serial number". The article number is found in the second line of the serial number. Control function The controller controls the Vaillant heating system and hot water generation of a connected domestic hot water cylinder. 3.4.1...
3.4.3 ’VR 66’ Control Centre If a ’VR 66’ Control Centre is connected, you can control two independent heating circuits with just one ’VRT 350’ controller; e.g. one heating circuit is in the single-occupancy house and the second heating circuit is in a guest apart- ment in this building.
«Auto» mode right-hand selector button 8 Mode set for the heating (soft key function) mode The basic display is the permanently visible display on the screen. The basic display shows the current settings and Operating instructions VRT 350 0020135485_00...
A flashing highlighted value means that you can change the value. Note If you do not operate the controller during a period of more than 5 minutes, the basic display appears in the display again. 0020135485_00 VRT 350 Operating instructions...
Desired temperature 20,0°C Menu Mode Image 4.5: Basic display If the display does not show the basic display, press the left-hand selector button, «Back», until the basic display appears again. 2. Press the left-hand selector button, «Menu». Operating instructions VRT 350 0020135485_00...
«OK» (to confirm the change). Date / Time Date 13.03.11 Time Daylight saving Cancel Image 4.11: Setting level: Accept the changed value 8. Turn the control knob to change the value. 0020135485_00 VRT 350 Operating instructions...
Period 2: _ _ : _ _ - _ _ : _ _ Period 3: _ _ : _ _ - _ _ : _ _ Back Select Back Select 4.14: Menu structure part 1 Operating instructions VRT 350 0020135485_00...
Page 15
Change Basic settings Factory reset? Offset Time programme Change heating circuit name Everything Factory reset Back Select Back Select Menu Enter code Basic settings Installer level ------------------------------------------------- Back Select Back 4.15: Menu structure part 2 0020135485_00 VRT 350 Operating instructions...
– If nothing is entered in the "Selection level 2" column, you will be taken from "Selection level 1" directly to the "Setting level". 4.4.2 Entering your own settings ▶ In the last column, "Own setting", enter the values that have been set by you. Operating instructions VRT 350 0020135485_00...
Serial num- Unit number Permanent value If the ’VR 66’ is connected, the functions shown in italics are only available for Zone 1 and these are only shown in the display for the main controller. 0020135485_00 VRT 350 Operating instructions...
Page 18
If the ’VR 66’ is connected, the functions shown in italics are only available for Zone 1 and these are only shown in the display for the main controller. Table 4.3: Overview of operating levels Operating instructions VRT 350 0020135485_00...
If you are absent during a frosty spell, ensure that the heating installation re- mains in operation and provides ad- equate frost protection. «Menu» → «Desired temperatures» → «HEATING 1» – You can set two different desired temperatures for the heating circuit. 0020135485_00 VRT 350 Operating instructions...
The «Time programmes» function can be used to set the time period for the heating circuit and hot water generation. If you have not set any time periods, the controller uses the time periods set in the factory settings. Operating instructions VRT 350 0020135485_00...
Page 21
«day temperature». Outside this time period, the controller switches to the set-back mode and the heating circuit heats the connected rooms to the desired «set-back temperature». 0020135485_00 VRT 350 Operating instructions...
5.2.6 Setting the time «Menu» → «Basic settings» → «Date/Time» → «Time» – Select this function to set the current time. All controller functions that contain a time relate to the set time. Operating instructions VRT 350 0020135485_00...
«Menu» → «Basic settings» → «Change heating circuit nam- ing» – You can now modify the factory-specified heating circuit names as you wish. The name is limited to 10 characters. 0020135485_00 VRT 350 Operating instructions...
– The heating function is switched off. The frost protection function is activated. 5.3.2 Modes for hot water production The operating mode for hot water generation corresponds to the heating circuit operating mode that has been set. You cannot set a deviating operating mode. Operating instructions VRT 350 0020135485_00...
Hot water generation is switched off and frost protection is activated. If the display shows «1 Day away from home active», you can use the rotary knob to set the desired «Set-back» tem- perature for the heating circuit. 0020135485_00 VRT 350 Operating instructions...
Page 26
Information → System status → Status". As soon as a fault message for the heating system appears, the «Status» set- ting level will display «Fault». In this case, the right function key has the function «Display». Operating instructions VRT 350 0020135485_00...
▶ If you need hot water rarely or outside the set time peri- are left open). ods, use the function «Cylinder boost». ▶ Heat all rooms in your dwelling evenly and according to their use. 0020135485_00 VRT 350 Operating instructions...
No changes in the – If the error is display via the still present, selector buttons inform the com- petent person Table 7.1: Detecting and rectifying faults Operating instructions VRT 350 0020135485_00...
▶ In this case, make sure that the Vaillant unit and any accessories are properly disposed of at the end of their useful life. As this Vaillant unit is covered by the law regarding the...
Warranty and customer service Warranty Guarantee We only grant a Vaillant manufacturers warranty if a suit- ably qualified engineer has installed the system in accord- ance with Vaillant instructions. The system owner will be granted a warranty in accordance with the Vaillant terms and conditions.
< 50 mA Supply line cross-section 0.75 … 1.5 mm² Level of protection IP 20 Protection class Maximum permissible ambient 50 ℃ temperature Height 97 mm Width 147 mm Depth 50 mm Table 10.1: Controller 0020135485_00 VRT 350 Operating instructions...
The room temperature is the temperature actually meas- If the temperature in the DHW cylinder falls by a specific ured in the dwelling. amount, the water is heated up again to the target «Hot water circuit» temperature. Operating instructions VRT 350 0020135485_00...
This access level contains all the additional functions that can be changed by the competent person; these must not be changed without specialist knowledge. This access level is reserved for the competent person and is therefore pro- tected by an access code. 0020135485_00 VRT 350 Operating instructions...
Page 34
Hot water generation............. 19 Intended use ..................7 set ....................19 Setting ..................19 Display Language Article number................8 Selecting................... 22 Serial number................8 set ....................22 Time programmes..............21 Level of protection............... 32 Timer programs..............22 Operating instructions VRT 350 0020135485_00...
Page 35
Room temperature..............32 Type designation Set offset ................. 23 Table.................... 8 Saving energy................27 Scalding Drinking water ................6 Scheduling Days away from home ............22 Selection level ................11, 32 Service..................... 30 Service message ................25 0020135485_00 VRT 350 Operating instructions...