Temperature Adjustment And Switch Functions; Controller Alarms And Signals - Minus Forty 07-CSGF Owner's Manual

Glass door undercounter and countertop freezers
Table of Contents

Advertisement

TEMPERATURE ADJUSTMENT AND SWITCH FUNCTIONS

Locate the electronic control at the lower front of the freezer. The electronic control displays the actual
temperature inside the freezer. In addition, the electronic control turns the refrigeration system OFF
when freezer reaches the set temperature, and turns the refrigeration system ON after the freezer tem-
perature rises by 3˚F.
To adjust the set temperature, follow these steps:
1. Press and release P button; the set temperature and SP1 are displayed alternatively on the controller
2. Press the UP or DOWN buttons to adjust the set temperature.
3. Press P to store the adjusted value; The electronic control will return to cabinet temperature
display. The U Button on the electronic controller is used for displaying cabinet and defrost
temperatures (PR1 and PR2 parameters)
There are two switches located on the right hand side of the controller.
Their functions are to manually switch electronic components of the freezer.
1. FREEZER switch turns the refrigeration system (including all electrical parts) ON or OFF.
2. LIGHT switch turns the internal and external lights ON or OFF.
ELECTRONIC CONTROLLER
ELECTRONIC CONTROL

CONTROLLER ALARMS AND SIGNALS

The electronic controller can detect and signal several alarm conditions: high/low freezer temperatures,
door open and open or short-circuited temperature probes. If the alarm conditions last longer than pre-
programmed time delays, the controller will turn ON an audio signal (buzzer). Also a LED light located
in the upper left corner of the controller, next to the caution symbol, will glow in case an alarm is active.
Once the alarm conditions have been fixed, the controller will turn off the alarms on its own. Alarms can
be disabled by pressing any controller button, during alarm conditions
Message
Prl diSC
Cabinet temperature probe open
Prl Short CC
Cabinet temperature probe short-circuited
Pr2 diSC
Defrost probe open
Pr2 Short CC
Defrost probe short-circuited
Int Error
Internal memory error
4
FREEZER
LIGHT
Cause
Action
• Check connections
• Replace probe
• Check connection
• Replace probe
• Replace controller
INTERIOR LED STRIP REPLACEMENT
Make sure the freezer is disconnected from the power supply before any service. Press the
freezer switch to the "Off" position then unplug the power cord from electrical receptacle.
All service work must be conducted by a certified technician only.
Remove silicone corner beads.
Slide broken LED strip from
Pry the screwdriver between
plastic cover.
plastic cover and cabinet frame.
Pry from one end to the other.
Install the new LED strip into
Attach wires, observing color
the plastic cover.
coding. Snap plastic cover
back to cabinet frame.
WARNING
Locate the wire for the LED
strip in the electrical box.
Plug the freezer in and make
sure the light switch is in the
'ON' position.