Page 2
GDS102 Operation and Installation Manual SKIPPER Electronics AS IMPORTANT When doing service or repair, please wait two minutes after power off, before unplugging internal connectors. Copying of this document, and giving it to others and the use Weitergabe sowie vervielfältigung dieser unterlage, verwertung...
Transducers GDS102 is prepared for connection of 1 or 2 transducers with a resonant frequency in the range of 10 - 265 kHz. Transmitter stage of the transceiver PCB is tuned to impedance of 100 Ohm, so the transducer type (if not supplied by SKIPPER) should be selected accordingly.
Flash). A HP Deskjet printer or Epson D88 printer with Centronics (parallel) interface may be connected for a paper copy, (ask SKIPPER for printer specification). Alternatively an Epson LQ-300+ printer for continuous paper feed may be used. Printer is only required when hard copy documentation is necessary.
Page 7
GDS102 Operation and Installation Manual SKIPPER Electronics AS Navigator NMEA 0183 Speed Log NMEA 0183 Repeater IR301 NMEA 0183 Cabinet Logging to Compact Flash External printer 115/230 V AC 24 V DC 2 x 2.5 sq. mm screened. Computer system...
External control and synchronization of transmitter (optional). Alarms Shallow and deep water alarms may be adjusted on screen 1. A relay output is provided in GDS102 for interface to external alarm systems. At local alarm conditions, an audible alarm is also provided.
GDS102 Operation and Installation Manual SKIPPER Electronics AS Sound Speed Calibration This option will enable adjustment of the sound speed value used for the depth calculations. The standard value is 1500 m/s, but the user may set values from 1400 to 1550 m/s to accommodate accurate propagation speed in known water conditions.
GDS102 Operation and Installation Manual SKIPPER Electronics AS 2 Operation When the installation is complete, and power is connected to the operator unit, the system is switched on-off by a power switch inside the cabinet. Parameter entry 2. Operation The fixed function buttons, the soft key buttons and the rotating encoder allow the user to adjust the parameters, setpoints and other data.
GDS102 Operation and Installation Manual SKIPPER Electronics AS Operation Screens Each of the operation screens contains a graphic picture and a selection of up to 6 soft key buttons. The various screens are selected by keeping the SCREENS button pressed and rotating the encoder in either direction.
GDS102 Operation and Installation Manual SKIPPER Electronics AS Primary Operation Screens (screen 1 - 3) The following figures show the operation of the primary operation screens. Some of the soft keys are self explanatory. Refer to the corresponding chapter in “Principal Functions” for more information about particular features.
Page 13
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 2.3. Screen 2. Display and print settings. Soft key Name Range/value Default value Description DISPLAY v.split / h.split v.split Selection of screen layout (either vertical or horizontal split of the total screen area, only primary transducer). Note: If only one of...
Page 14
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 2.4. Screen 3. Power adjustment and options. Soft key Name Range/value Default value Description SELECT CHN Ch1/Ch2 Ch 2 Selected channel enables adjustment of POWER, and DRAUGHT. The channel frequency is displayed next to the channel number.
Pos? Transducer position. Information is being indicated on the PORT/STRB/ screen for easy reference to the transducer and used in SKIPPER not inst./pos? proprietary NMEA sentence. Note: If “not inst” (not installed) is selected, the corresponding channel is not operative and will never be displayed (single channel mode).
Page 16
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 2.6. Screen 5. Calendar and clock setting. Soft key Name Range/value Default value Description Not used. YR.MONTH 01.04-... Year and month setting. 1 - 31 Date setting. HOURS 0 - 23 Hours setting.
Page 17
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 2.7. Screen 6. Units of measurement. Soft key Name Range/value Default value Description LANGUAGE English, French, Spanish, English Screen language selection. German, Norwegian DEPTH Meters, feet, fathoms, Meters Unit of measurement for depth.
Page 18
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 2.8. Screen 7. Interface setup screen. Soft key Name Range/value Default Description value 1 (Optional) ENABLE Pos/neg Selection of polarity of remote sounding control signal. Note: This function is operative, if remote sounding control option is installed.
Page 19
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 2.9. Screen 8. Recordings selection and play back. If recording mode is activated, the depth and all essential navigational data along with echo sounder settings will be written into the files on the Compact Flash disk. The left half of this screen (recordings directory) represents the list of the recorded files which are sorted by the time of the recordings.
Page 20
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 2.10. Screen 9. Recordings options. Soft key Name Range/value Default value Description SCREEN Print Screen hardcopy, can be used for documentation and trouble-shooting. CLEANUP Records If the clock is changed, two files for the same date/time can exist. If this is the case, the new data will be added to the original data.
Page 21
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 2.11. Screen 10. NMEA control screen. The window on the left part of the screen displays the received or transmitted messages, depending on the selection of the DISPLAY soft key. Useful for verification of received and transmitted messages.
Page 22
Screen hardcopy, can be used for documentation and trouble-shooting. PRINT TYPE HP Deskjet, Epson Epson-D88 The printer type. (Ask SKIPPER for printer specification) D88, LQ-300+ SIMULATE On/off Toggles built-in simulator. When simulator is activated, flashing “DEMO” text is displayed in the upper right corner of the screen.
Page 23
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 2.13. Screen 12. Oscilloscope screen. The screen can be used for transceiver and transducer trouble-shooting. Left part of the screen consists of the following areas: A) The graphical real-time presentation of the received echo signal versus time (oscillogram window).
Page 24
GDS102 Operation and Installation Manual SKIPPER Electronics AS Only one channel at a time is displayed in oscillogram window. Soft key 2 SELECT CHN can be used to select required channel for observation. The oscillogram on fig 2.13 shows detected bottom signal (next to red marker) followed by secondary and third reflections of bottom signal.
GDS102 Operation and Installation Manual SKIPPER Electronics AS Principal Functions. Graphics Soft key texts Soft keys Encoder Depth Picture Screen Day/Night Brightness range speed select Depth Range The DEPTH RANGE button can be used to set the depth limit between 10 and 5000 m. The maximal depth range can be reduced by soft key MAX RANGE, screen 7.
GDS102 Operation and Installation Manual SKIPPER Electronics AS Screen (select) The SCREEN button facilitates selection of one of the 12 screen and soft key layouts. The 3 primary operation screens may be cycled by repeatedly pressing the SCREEN button. Access to the remaining screens is through encoder operation.
Data Logging (Recordings Memory) GDS102 has a capability of recording continuously for 24 hours. All related functions are presented on screens 8 and 9; ref. description of these screens for further details. Depth, time and whatever navigational information is available (position, speed, heading), are stored continuously.
Basic Algorithm Considerations Bottom detection GDS102 employ a bottom detection algorithm that will try to extract the bottom signal from all kinds of noise and secondary echoes. When GDS102 is tracking the bottom normally, a thick black line is shown.
Page 29
GDS102 Operation and Installation Manual SKIPPER Electronics AS is detected in the calculated window, the window is gradually increased in size until the full time and strength window is used. WARNING! False bottom echoes may occur when: • The bottom is out of range.
GDS102 Operation and Installation Manual SKIPPER Electronics AS 3. Installation Standard System Supply A basic GDS102 system consists of the following units. (Ref. fig. 3.1): 1. Operator unit with installation material. 2. Transducer junction box(es). 3. Approved transducer steel tank(s) and sea valves.
Page 31
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 3.1. Basic System Configuration. Page 31 of 69 Version: 20100811 Sw 1.12.3.0...
GDS102 Operation and Installation Manual SKIPPER Electronics AS Transducer Junction Box. The standard cable fitted on the transducer is 25 m or 40 m and may be shortened. The junction box is used to interconnect the transducers fixed cable to a yard supply extension cable if the total required cable length is longer than the standard cable.
115/230 V AC. The transducer is always connected with 1 pair plus screen. If the AC power system is 115 V, GDS102 must be prepared for 115 V AC by re-connecting the connectors J102, J103 as shown in fig. 3.4.
Page 34
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig 3.3. Operator unit. Page 34 of 69 Version: 20100811 Sw 1.12.3.0...
GDS102 Operation and Installation Manual SKIPPER Electronics AS Voltage selection connectors and fuses, Terminal Board Fig 3.4. AC Voltage selection and fuses. Transformer primary to: • J102 for 230 V AC. • J103 for 115 V AC. (Fit dummy plug on opposite connector for protection).
Page 37
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 3.6. Data Communication Interfaces. Page 37 of 69 Version: 20100811 Sw 1.12.3.0...
GDS102 Operation and Installation Manual SKIPPER Electronics AS Back-up battery jumper JP 200 Fig. 3.7. Back-up battery jumper JP200, on I/O board. Important: After the installation is complete and the system power is applied, it is necessary to connect the back-up battery to provide power to the user parameters during system power failure.
GDS102 is equipped with 2 analogue outputs to supply analogue repeaters or other equipment with analogue inputs. The signals are galvanically connected to the GDS102. Standard range is 0 - 10 V or 4 - 20 mA. Ref. fig. 3.8, 3.9 and 3.10 for more details.
External printer connection The external HP Deskjet or Epson D88/LQ-300+ printer with Centronics interface can be connected to the GDS102 parallel port, located on the external panel of the cabinet. Ref. fig. 3.5 for port allocation and 3.6 for connector details.
KEYB+ Keyboard signal. Remote Sounding Control This option lets the GDS102 being controlled remotely in continuous/edge/level/single ping modes. If installed, these options are accessible on screen 3. Ref. fig. 3.8, 3.9 and 3.10 for more details. J100 Symbol J100 #...
FWD (bow), AFT (aft the ship), PORT (portside) and STRB (starboard). This information will be indicated on the screen and used in SKIPPER proprietary NMEA sentences. If only one transducer is installed, it is advisable to select “not inst.” value for the second transducer. This will disable transmissions on this channel and the text line in the upper part of the screen will contain information (frequency and draught) about one channel only.
Depth below transducer SDDBT,xxxx.x,f,xxxx.x,M,xxx.x,F*hh<CR><LF> Depth below keel SDDBK,xxxx.x,f,xxxx.x,M,xxx.x,F*hh<CR><LF> Set Alarm State SDALR,hhmmss.ss,xxx,A,A,c--c*hh<CR><LF> In case of multiple transducers installation the following SKIPPER proprietary sentence can be selected by enabling format SKP1 and/or SKP2. $PSKPDPT,x.x,x.x,x.x,xx,xx,c-c*hh<CR><LF> Checksum Transducer location. * Echo sounder channel number (0-99).** Bottom echo strength (0-9).
Page 48
** = 1 (for SKP1) or 2 (for SKP2). Note: SKP1 format is presenting information, which is linked to the echo sounder channel 1, while SKP2 - to operating channel 2. Each of these two formats can be enabled/ disabled individually. The following messages are accepted for input to GDS102. The talker identifier is ignored. Time Universal time ZZU,xxxxxx Universal time &...
GDS102 Operation and Installation Manual SKIPPER Electronics AS Frequency setup The frequencies of both channels are preset in production. It is possible to change the settings. To do so, it is necessary to set the required values on the DIP switches on the dual transceiver PCB, according to table 4.3 and adjust the displaying value on screen 4 (soft key FREQUENCY).
Page 50
GDS102 Operation and Installation Manual SKIPPER Electronics AS Table 4.3 Frequency DIP switch settings, SW3 for Ch 1 (50 - 265 kHz), SW2 for Ch 2 (10 - 50 kHz) Frequency SW2/SW3 settings Frequency Dip 1 Dip 2 Dip 3...
Page 51
GDS102 Operation and Installation Manual SKIPPER Electronics AS Table 4.3 Frequency DIP switch settings, SW3 for Ch 1 (50 - 265 kHz), SW2 for Ch 2 (10 - 50 kHz) Frequency SW2/SW3 settings Frequency Dip 1 Dip 2 Dip 3...
Page 52
GDS102 Operation and Installation Manual SKIPPER Electronics AS Table 4.3 Frequency DIP switch settings, SW3 for Ch 1 (50 - 265 kHz), SW2 for Ch 2 (10 - 50 kHz) Frequency SW2/SW3 settings Frequency Dip 1 Dip 2 Dip 3...
Page 53
GDS102 Operation and Installation Manual SKIPPER Electronics AS Table 4.3 Frequency DIP switch settings, SW3 for Ch 1 (50 - 265 kHz), SW2 for Ch 2 (10 - 50 kHz) Frequency SW2/SW3 settings Frequency Dip 1 Dip 2 Dip 3...
Page 54
GDS102 Operation and Installation Manual SKIPPER Electronics AS Table 4.3 Frequency DIP switch settings, SW3 for Ch 1 (50 - 265 kHz), SW2 for Ch 2 (10 - 50 kHz) Frequency SW2/SW3 settings Frequency Dip 1 Dip 2 Dip 3...
Page 55
GDS102 Operation and Installation Manual SKIPPER Electronics AS Table 4.3 Frequency DIP switch settings, SW3 for Ch 1 (50 - 265 kHz), SW2 for Ch 2 (10 - 50 kHz) Frequency SW2/SW3 settings Frequency Dip 1 Dip 2 Dip 3...
GDS102 Operation and Installation Manual SKIPPER Electronics AS Options Calibration, Sound Speed The only possible calibration activity is when the sound speed option is installed. In this case, set the required sound speed value on screen 3. Remote sounding control When this option is installed, transmitter operation may be controlled by the external signal.
If it is possible to cycle through the screens and view information, several assumptions may be made regarding operation of the GDS102 system. Although some of the subsystems necessary for this basic system operation may still suffer from minor or intermittent operation disorders, the fact that it is possible...
GDS102 Operation and Installation Manual SKIPPER Electronics AS Fig. 5.1. Function LEDs, on terminal board. Function LEDs. The following LEDs are located on the terminal board as shown in fig 5.1: • LD700: +5 V#1/VCC (5 V CPU, Board External and CPU).
GDS102 Operation and Installation Manual SKIPPER Electronics AS Typical Status Screen 11 Contents The status screen 11 contains information that will facilitate analysis and correction of several problems. A printout of the status and oscilloscope screens should be sent with any report about functional disturbance.
Page 60
GDS102 Operation and Installation Manual SKIPPER Electronics AS Symptom Cause Remedy Basic system integrity 1. No picture on LCD Screen. 1. No AC or DC power to the 1. Check switches and fuses on system. the terminal PCB inside the 2.
Page 61
GDS102 Operation and Installation Manual SKIPPER Electronics AS Symptom Cause Remedy NMEA and external interfaces. 1. NMEA input signals are not 1. Wrong polarity input signals. 1. Swap NMEA input wires. listed on the NMEA screen 2. NMEA port, selected for 2.
GDS102 Operation and Installation Manual SKIPPER Electronics AS 6. User Maintenance Transducer maintenance The transducers are virtually maintenance free, but occasional cleaning may be necessary depending on sea water conditions and organic growing on ship’s hull. Operator Unit Maintenance The operator unit contains no user serviceable parts, and requires no maintenance apart from occasional cleaning of the front panel.
GDS102 Operation and Installation Manual SKIPPER Electronics AS 7. System Specifications Functional Properties Display 158 x 211 mm (10.4”) TFT colour LCD screen with adjustable contrast and backlight. 640 x 480 pixels. Printer Optional external printer, HP Deskjet, Epson D88 or Epson LQ 300.
GDS102 Operation and Installation Manual SKIPPER Electronics AS Environmental according to IEC 60945: Transducer and Junction Box Operating temperature -15 to +55 degrees C. Storage temperature -20 to +70 degrees C. Protection, transducer 6 bar. Protection, parts inside hull IP 66.
GDS102 Operation and Installation Manual SKIPPER Electronics AS 8. Service All service requests should be made to the local SKIPPER representative. Adjustments and repairs should only be performed by qualified service engineers. Unqualified repair attempts will void the warranty. Page 66 of 69...
2. Connect a VGA screen to the CPU board. 3. Switch the GDS102 power switch “ON” while pressing the ‘’DELETE’’ key on the PC keyboard. 4. Do not release ‘’DELETE’’ key until several clicks , beeps and signals have been heard, and picture is present on the VGA screen.
Then press down and keep pressed the soft key to the far right and far left (no. 1 and 6) in the upper row on the GDS102 keyboard. • Turn “on” the GDS102, and keep the two soft keys pressed down until the screen shows the normal picture. This may take as long as app. 30 seconds. •...
Need help?
Do you have a question about the GDS102 and is the answer not in the manual?
Questions and answers