200hz lcd tv signature series in full hd, premium series in full hd, true cinematic series, modern classic series, sleek & stylish series, home theatre systems, portable dvd players (2 pages)
SERVICE MANUAL EG1L CHASSIS MODEL COMMANDER DEST. MODEL COMMANDER DEST. KDL-40Z4500 RM-SD001 Chinese KDL-46Z4500 RM-SD001 Chinese KDL-52Z4500 RM-SD001 Chinese RM-SD001 KDL-40Z4500/46Z4500/52Z4500 LCD Digital Colour TV D846660B279CC0D5520DEF8E80C6FD0B0509C3DE5F2E1AA671B63DA146255667FE11BD8887335EC9...
SPECIFICATIONS Model name KDL-52Z4500 KDL-46Z4500 KDL-40Z4500 System Panel system LCD (Liquid Crystal Display) Panel TV system Analogue: D/K, I, B/G, M Digital: GB20600-2006 Colour system Analogue: PAL, PAL60, SECAM, NTSC3.58, NTSC4.43 Digital: MPEG-2 MP@HL, MP@ML Analogue: D/K: VHF: C1 to C12, R1 to R12/ UHF: C13 to C57, R21 to R60/...
1) Do not press on the panel or frame edge to avoid the risk of electric shock. Replace all components with Sony parts whose part numbers 2) Do not scratch or press on the panel with any sharp objects. appear as shown in this manual or in supplements 3) Do not leave the module in high temperatures or in areas of published by Sony.
SAFETY CHECK-OUT After correcting the original service problem, perform the Leakage Test following safety checks before releasing the set to the customer: The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part 1.
SELF DIAGNOSIS FUNCTION The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY LED will automatically begin to flash. The number of times the LED flashes translates to a probable source of the problem. A definition of the STANDBY LED flash indicators is listed in the instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the remote commander can be used to review the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Page 7
SELF-DIAGNOSTIC SCREEN DISPLAY For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confirmed, it is possible to bring up past occurrences of failure for confirmation on the screen: [To Bring Up Screen Test] In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below: [ SELF-DIAGNOSTIC SCREEN DISPLAY ] BALANCER...
Page 29
English Sony EMCS Corporation 2008KL08-Data Made in Japan Inazawa TEC 2008. 11 9-888-237-01 KDL-40/46/52Z4500 (CH) D846660B279CC0D5520DEF8E80C6FD0B0509C3DE5F2E1AA671B63DA146255667FE11BD8887335EC9...
Need help?
Do you have a question about the KDL-40Z4500 and is the answer not in the manual?
Questions and answers