Redarc BCDC1225 Instruction Manual

Redarc BCDC1225 Instruction Manual

25a in-vehicle 3-stage 12v battery charger
Hide thumbs Also See for BCDC1225:

Advertisement

25A In-vehicle 3-Stage
12V Battery Charger
BCDC1225

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BCDC1225 and is the answer not in the manual?

Questions and answers

Geoff Zuber
February 2, 2025

Will my 1225 select battery type automatically?

User image 679ed63ec1732
2 comments:
Geoff Zuber
February 2, 2025

@Geoff Zuber the solar selects calcium type battery automatically whereas the 1225 is selecting AGM/gel

Mr. Anderson
February 10, 2025

No, the Redarc BCDC1225 does not automatically select the battery type. It is designed to charge the auxiliary battery optimally based on the selected battery type.

This answer is automatically generated

Summary of Contents for Redarc BCDC1225

  • Page 1 25A In-vehicle 3-Stage 12V Battery Charger BCDC1225...
  • Page 2: Warnings And Safety Instructions

    Attempting to service the unit yourself may result in electric shock or fi re and will void the unit warranty. Do NOT use the BCDC1225 to charge non-rechargeable batteries. Doing so may result in harm to the user and/or damage to the BCDC1225. Only use the BCDC1225 for charging Standard Lead Acid, Calcium content, Gel &...
  • Page 3: Table Of Contents

    5. External LED Indication 6. Display Panel 7. Error Codes 2 Installation 1. Wiring 3 Troubleshooting 4 Frequently Asked Questions 5 Two Year Warranty Specifi cations BCDC1225 DC Input Voltage Range 9V-32V Gel/AGM Std Lead Acid Calcium Content Absorption Voltage 14.5V 14.9V 15.3V...
  • Page 4: Product Function

    12V or 24V nominal or a 12V nominal solar panel input. The input voltage of the BCDC1225 can be above, below or equal to the output voltage making it ideal for charging an auxiliary 12V battery where the distance from the main battery may cause a signifi...
  • Page 5: Turn On/Off Thresholds

    Shutdown if Output Battery < 4V Charging Algorithm When the BCDC1225 is turned on, it will move into the bulk charging stage called Boost stage. Boost stage maintains a constant current until the battery voltage reaches its set point. The current in Boost stage may vary during operation in order to maintain safe operating temperature, or to limit the difference between input and output voltage.
  • Page 6: External Led Indication

    Charging or maintaining charge Display Panel The BCDC1225 has three Battery Type Settings available. These settings enable optimal charging profi les for the auxiliary battery. The battery type selected is displayed via the LEDs on the front panel in the section ‘Battery Type’. In addition to the battery type, the status of the charger is indicated via three LEDs.
  • Page 7: Error Codes

    Mount the unit to a fl at surface close to the auxiliary battery and away from any heat sources. Wire into vehicle as per the applicable diagram on the next pages, and following the steps below. The BCDC1225 is connected using 6 wires, listed below: • Source Select Blue • Battery Type Orange •...
  • Page 8 INSTALLATION 1. Wire the ‘Common Ground’ wire to a ground point that is common to both the Start battery (or the Solar Input Ground wire) and the Auxiliary battery to be charged. This point may be on the chassis of the vehicle, on the chassis of the trailer/ camper/caravan or directly wired to both batteries, depending on your installation requirements.
  • Page 9: Wiring

    Calcium) may need to be selected to avoid damage to the battery. Wiring The heavy gauge wires on the BCDC1225 unit carry peak currents of up to 35 Amps, and it is important to make a good, low resistance, electrical connection that will not degrade over time.
  • Page 10 INSTALLATION Crimp here. Slip heatshrink over wire and insert wires into Crimp both wires to the butt splice using indent butt splice. Keep heatshrink away from joint until type crimpers. after soldering is complete and has cooled. Solder here. Solder the wires to the butt splice. Ensure that a Wait for the butt splice to cool, slip heatshrink good connection is made.
  • Page 11 INSTALLATION SOLAR INPUT 12 Solar Panel Array Load Loads Fuse Fuse Battery config wire Note: Power wires must be All ground points must Auxiliary at least 6mm² and must be be connected to chassis Battery crimped using an earth. appropriate crimp tool. Figure 2.3 - Standard setup for a 12V Solar array INPUT Load...
  • Page 12 SOLAR INPUT INPUT 12V Solar Panel Array 12V Changeover Load Relay (40A) Loads Fuse Fuse Fuse Battery config to vehicle wire ignition Note: Power wires must be All ground points must Start Auxiliary at least 6mm² and must be be connected to chassis Battery Battery crimped using an...
  • Page 13: Troubleshooting

    4v? system or contact Redarc If the battery voltage is Electronics for more information. still low, replace battery. Figure 3.1 - Standard BCDC1225 Troubleshooting Guide...
  • Page 14: Frequently Asked Questions

    fi ne, what’s the problem? The most likely cause of this issue is that the BCDC is somehow ‘stuck’ in 24V mode. Try removing the ‘Source Select’ (Blue) wire and reconnecting it. If the problem still exists please contact Redarc Electronics.
  • Page 15: Two Year Warranty

    Friendly, personalised, professional service and product support In the unlikely event that a technical issue arises with a Redarc product, customers are encouraged to initially contact the Redarc Technical Support Team on (08) 8322 4848 In the unlikely event that a technical issue arises with a Redarc product, customers are encouraged to initially contact the Redarc Technical Support Team on (08) 8322 4848 or or power@redarc.com.au...
  • Page 16 Free technical assistance! please contact Redarc Electronics 23 Brodie Road North, Lonsdale SA (08) 8322 4848 power@redarc.com.au www.redarc.com.au Copyright © 2012 Redarc Electronics Pty Ltd. All rights reserved. WARBCDC1225 - REV2 www.redarc.com.au...