Index Alignment Check Or Adjustment; Index Alignment Oscilloscope Settings - NEC FD1165 Maintenance Manual

Flexible disk drive
Hide thumbs Also See for FD1165:
Table of Contents

Advertisement

a.
Insert
the
alignment
flexible
disk
and
step
the
carriage to track 76.
b.
Load the heads.
c.
Compare the waveform in Figure 5-4 with the waveform
that is displayed on the oscilloscope.
d.
If
the waveform is not wi thin specifications,
re-
place the carriage assembly.
-
A
B
C
0
~
SPEC IFICATION
B~AANDC~
0
Figure 5-4
Azimuth Waveform
5.4.3
Index Alignment Check or Adjustment
Set the oscilloscope to the settings in Table 5-5, then use
the following procedure to check or adjust the Index align-
ment.
Table 5-5
Index Alignment Oscilloscope Settings
ITEM
SETTING
Channel 1
Normal
Channel 2
Inverted
Mode
Add
Inputs
Ac
Input ra.nge
200 mV/division
Test points
TP8 and TP9
Trigger
TP7 (dual-sided)
TPIO (single-sided)
Time base
0.1 ms/division
Probes
xl
5-7