6.13
Removal of Drum Door Buffers
(a)
Follow general servicing instructions for components within the cabinet. (Refer to
Section 6.6)
(b)
Remove the door grabber assembly.
Section 6.8)
(c)
Slide the drum door open.
(d)
Unclip the drum door buffer and remove from
underneath the drum door by pushing on the tab.
Reassembly
(a)
Refit in reverse manner.
Note: It is absolutely necessary that the drum door buffer is installed, as it provides static
discharge protection for the controllers.
6.14
Removal of Drum Door Key Bracket
(a)
Follow general servicing instructions for components
within the cabinet. (Refer to Section 6.6)
(b)
Slide the drum door partially open.
(c)
Push a small screwdriver blade through the holes in
the drum (4) to release the clips on the drum door key
bracket.
(d)
Lift the drum door key bracket clear.
Reassembly
(a)
Refit in reverse manner.
6.15
Removal of Drum Door Scraper
(a)
Follow instructions for removal of the drum door.
(Refer to Section 6.12)
(b)
Lift up the drum door scraper to unclip it from the
drum.
Reassembly
(a)
Refit in reverse manner.
(Refer to