Page 1
Riva PLUS WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY Please Read Instructions Carefully Save for Future Reference WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. —...
Page 3
CSA 4.9 and is CSA compliant. This Riva Plus boiler has a 2 year warranty, a copy of which is provided with the boiler. Please be sure to return the warranty registration card as the warranty will be void without your boiler's serial numbers (located on the ratings label affixed to the boiler), date of installation and the name of your installer being on record in our files.
12.4 Zone Valve Microswitch Connection 12.5 Circulator Sizing Circ. Cap. as a Function of Flow Rate 13.1 Expansion Vessel 13.2 Piping Primary-Secondary Piping 14.1 Primary-Secondary with Zone Valves 14.2 Manifold Piping with Zone Valves or Circ. 14.3 Riva Plus Manual...
Checking the Combustion Fan 17.7 Checking the Flue 17.8 45-46 Visual Inspection of Appliance 17.9 Gas Pressures and Soundness 17.10 Condensate trap 17.11 Venting Spare Parts Separate Vent 18.1 Coaxial Vent 18.2 Roof Vent 18.3 Installer Notes Riva Plus Manual...
Page 6
— Installation and service must be performed by a qualified installer, service agency or the gas supplier. DANGER Caution: Do not store or use flammable materials, chemicals or flammable liquids, especially gasoline, in the vicinity of this heating appliance. Riva Plus Manual...
Page 7
If any of the symptoms of CO occur, or if any of the signs of carbon monoxide are present, VACATE THE PREMISES IMMEDIATELY AND CONTACT A QUALIFIED HEATING SERVICE COMPANY OR THE GAS COMPANY OR THE FIRE DEPARTMENT. ONLY QUALIFIED, LICENSED SERVICE CONTRACTORS SHOULD PERFORM WORK ON YOUR BIASI RIVA HEAT ONLY BOILER. Riva Plus Manual...
- B149 Installation Codes E. ANSI/ASME - CSD-1 The above codes are available from: National Fire Protection Association (NFPA) CSA International Battery March Park 8501 E. Pleasant Valley Road Quincy, Massachusetts, 02269 Cleveland, OH 44134-5575 http://www.nfpa.org http://www.csa-international.org Riva Plus Manual...
1. General Information The Riva Plus is a high efficiency condensing, wall mounted gas boiler which provides central heat. The boiler features a gas valve which modulates the energy input from 49476 BTU/h to 116008 BTU/h. The boiler is shipped fully assembled with the components listed on page 11.
Page 10
Back 2.25/4 Coaxial 3.25/5 Sides Twin split pipes 3.25/3.25 Bottom Nominal heat flow rate Flue pipe enclosed 116.0 (0/2000ft) Flue pipe free air Nominal heat flow rate 110.2 (2000/4500ft) in Exhaust temperature °F Max Exhaust temperature °F Riva Plus Manual...
14. Modulation operator 31. Water supply inlet cock 15. Gas valve outlet pres. Test point 32. Condensate trap 16. Gas valve inlet pres. Test point 33. Condensing heat exchanger 17. Central heating expansion vessel 34. Flue termostat Riva Plus Manual...
4. Internal Piping & Parts List Note: Pressure Relief Valve (#19) should be piped to a drain or to the floor as lose as possible to a drain. Riva Plus Manual...
- white rd - red gy - grey Caution: Label all wires prior to disconnection when ye - yellow gnye - green/yellow servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing Riva Plus Manual...
CO detector in the boiler room. Air Opening 0 to 12" Figure 6.2 When choosing an installation location insure the exhaust and intake pipes comply with NFPA 54. The drawing on the next page illustrates the restrictions on exhaust locations. Riva Plus Manual...
USE ONLY LISTED COMPONENTS SUPPLIED WITH THE BOILER. SURFACE DISCOLORATION OF THE BUILDING MAY OCCUR DUE TO IMPROPER INSTALLATION. QHT WILL NOT ACCEPT RESPONSIBILITY OR LIABILITY FOR SUCH DISCOLORATION. The Exhaust Hood must be installed on the leeward side of house and conform to the following guidelines: 1.
3.25”) shown below as well as on the paper template. Remove paper template and hang boiler on bracket. Ø 3.1 Ø 3.1 A, B, C Ø 4.0 1.9 2.9 15.8 10.1 6.9 gas 2.5 2.6 15.2 Condense Figure 8.1 Riva Plus Manual...
CAN/CGA B149, Installation Codes. When resizing any portion of the common venting system, the common venting system should be resized to approach the minimum size as determined using the appropriate tables in Part 11 of the National Fuel Gas Code, ANSI Z223.1 and/or CAN/CGA B149, Installation Codes. Riva Plus Manual...
Page 19
3. A Product-approved vent terminal must be used, and if applicable, a Product-approved air intake must be used. Installation shall be in strict compliance with the manufacturer’s instructions. A copy of the installation instructions shall remain with the appliance or equipment at the completion of the installation. Riva Plus Manual...
Connect exhaust (inner) pipe to concentric elbow. • Connect intake (outer) pipe to concentric elbow. • Secure elbow to boiler using gasket and four screws provided. • Secure end cap on the intake pipe outside the house. • Riva Plus Manual...
Page 22
Attach each collar to the boiler with the gasket and screws provided. • Insert each elbow into its corresponding collar. • • Connect each pipe to its corresponding elbow (as shown in the diagram). Secure end cap on the intake and exhaust pipe outside the house. • Riva Plus Manual...
Page 23
Slide one rubber wall trim piece on the pipe from inside and one from outside. • Attach each collar to the boiler with the gasket and screws provided. • Insert each elbow into its corresponding collar. • Connect each pipe to its corresponding elbow. • Riva Plus Manual...
Page 24
Slide one rubber wall trim piece on the pipe from inside and one from outside. • • Attach each collar to the boiler with the gasket and screws provided. Insert each elbow into its corresponding collar. • Connect each pipe to its corresponding elbow. • Riva Plus Manual...
Page 25
Attach each collar to the boiler with the gasket and screws provided. Insert each elbow into its corresponding collar. • Connect each pipe to its corresponding elbow (as shown in the diagram). • Secure end cap on the intake and exhaust pipe outside the house. • Riva Plus Manual...
Page 26
Connect exhaust (inner) pipe to concentric elbow. • Connect intake (outer) pipe to concentric elbow. • • Secure elbow to boiler using gasket and four screws provided. Secure end cap on the intake pipe outside the house. • Riva Plus Manual...
The condenste trap is provided with two electrodes: if the drain pipe is plugged or in any case in which the condensate isn’t correctly evacuated, the condensate level in the trap rises putting in contact the electrodes thus causing the boiler lock-out. Riva Plus Manual...
The boiler and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa). WARNINGS DO NOT USE A FLAME FOR CHECKING GAS LEAKS Riva Plus Manual...
WARNING Note: Do not connect live wires to Power supply terminal block thermostat terminals 1-3. External controls terminal block Figure 12.5 • Connect the earth wire(yellow/green). Boiler must be wired directly to earth ground on breaker panel. Riva Plus Manual...
Fig. 12.12 • Replace the control panel To the external reversing the steps on control device To the fused spur isolation switch page Figure 12.12 Riva Plus Manual...
23 ft at most. For greater differences, increase the pre-load pressure in the C.h. expansion vessel (17 on page 11) and the system when cold, by 0.1 bar for additional 3.3 ft. For systems with volumes greater than 154l, an additional expansion vessel must be provided. Riva Plus Manual...
The second method is a hydraulic separator. Hydraulic separators are available commercially; however you can also construct your own. An example of a hydraulic separator is given in Figure 14.2. It is important that the separator be at least 2” in size to ensure proper performance. Riva Plus Manual...
14. Piping Cont. 14.1 Primary – Secondary Piping: All external piping components are to be supplied by the installer. It is very important to use a hydraulic separator before secondary circulators. Riva Plus Manual...
Page 35
14. Piping Cont. 14.2 Primary – Secondary Piping with Zone Valves: All external piping components are to be supplied by the installer. It is very important to use a hydraulic separator before secondary circulators. Riva Plus Manual...
Page 36
14. Piping Cont. 14.3 Manifold Piping with Zone Valves (shown conn. to radiators): All external piping components are to be supplied by the installer. Riva Plus Manual...
D will appear. To reset the boiler turn the knob B (figure 15.3) on the 0 position and then press and release the boiler reset button C (Fig. 15.3). Riva Plus Manual...
E (Figure points must be sealed. • Set the c.h. temperature 15.4). control knob to its Switch on the boiler. • maximum position. If • Check the minimum gas Riva Plus Manual...
(D on Figure 15.3). To reset the boiler turn the knob B (figure 15.3) on the 0 position and then press and release the boiler reset button (C on Figure 15.3). Riva Plus Manual...
15.7 and • By rotating device ensure that room clockwise pressure thermostat is set to “heat increases. demand”. • Adjust the gas pressure at the burner to the value according to the useful c.h. output wanted (Tab. 15.1). Riva Plus Manual...
All the labels supplied with the boiler are numbered for reference. According to Figure 15.10 place all the labels on the boiler. Use label numbered as 1 (already installed in the front panel) to begin the placement in the correct way. Riva Plus Manual...
• Loosen the screws A and the appliance has been L.P.G. remove burner set. (Figure 16.1). • Reassemble the front and • Carry out the conversion side panels of the case. type gas, replacing burner injectors correctly. Riva Plus Manual...
If you notice dirt on the fins of the primary heat exchanger (9 on page 10), cover the sloping surfaces of the burner (7 on page 10) entirely in a protective layer (sheets of newspaper or similar). Brush out the primary heat exchanger (9 on page 10) with a bristle paintbrush. Riva Plus Manual...
Inspect the venture device inside the Remove the first elbow from the • • outlet of the combustion fan. Make sure horizontal run of the exhaust to the that it is free of any dirt build up or outside. blockage. • Riva Plus Manual...
Using pliers, remove the spring D moving it • upwards. Disconnect the wirings from the trap. • • Reassemble carrying out the removal operations in reverse order. The trap should be serviced once a year during the annual service. FIG. 17.6 Riva Plus Manual...
Page 47
Separate flue vent pipe Separate vent sealing gaskets Separate vent 90 degree elbows Boiler vent adapter hardware Separate flue intake pipe Separate flue intake boiler adapter Separate flue exhaust boiler adapter Exhaust adapter gasket Exhaust restrictor Separate flue intake termination Riva Plus Manual...
Page 48
18. Vent Part Spares Cont. Part Description Order Number Coaxial intake pipe Coaxial termination pipe Coaxial union clamp Coaxial union gasket Coaxial exhaust gasket Coaxial boiler adapter gasket Coaxial boiler adapter Coaxial boiler adapter hardware Coaxial union clamp hardware Wall gaskets Riva Plus Manual...
Page 49
Roof venting intake adapter Roof venting intake gasket Roof venting boiler adapter exhaust gasket Roof venting boiler adapter Roof venting boiler adapter hardware Roof venting boiler adapter gasket For any spare parts, please contact QHT Inc. at 800-501-7697. Riva Plus Manual...