Download Print this page
Panasonic HIT Double Photovoltaic modules General Installation Manual

Panasonic HIT Double Photovoltaic modules General Installation Manual

Advertisement

Quick Links

General Installation Manual
© Apr 2012, SANYO Electric Co., Ltd. All Rights Reserved
General
Installation
©
Panasonic HIT
Double Photovoltaic
Modules,
manufactured
Please read this manual completely
before installation or use of HIT Double
modules.
This manual applies to the
following products:
HIT Double 195
(VBHB195DA03, VBHB195DA03B)
HIT Double 190
(VBHB190DA03, VBHB190DA03B)
HIT Double 186
(VBHB186DA03)
INTRODUCTION
Thank you for choosing Panasonic HIT
Double PV modules. With proper operation
and maintenance, Panasonic modules will
provide you with clean, renewable solar
electricity for many years. This manual
contains important installation, maintenance
and safety information. The word "module"
as used in this manual refers to one or
more PV modules. Retain this manual for
future reference.
Disclaimer of Liability
SANYO does not assume responsibility and
expressly
disclaims
liability
damage, or expense arising out of, or in
any
way
connected
with
operation, use, or maintenance by using
this manual.
SANYO assumes no responsibility for any
infringement of patents or other rights of
third parties, which may result from use of
modules.
No license is granted by implication or
under any patent or patent rights. The
information in this manual is believed to be
reliable,
but
does
not
expressed and/or implied warranty.
SANYO reserves the right to make changes
to the product, specifications, or this
manual without prior notice.
The return of any modules will not be
accepted by SANYO unless prior written
authorization has been given by SANYO.
General Information
The installation of solar modules requires a
great degree of skill and should only be
performed
by
qualified
professionals, including, without limitation,
licensed contractors and electricians.
WARNING
All instructions should be read and
understood before attempting to install,
wire,
operate,
and/or
photovoltaic
module.
generate DC electrical energy when
exposed to sunlight or other light
Manual
for
sources. Contact with electrically active
parts of the module such as terminals
by
SANYO.
can result in burns, sparks, and lethal
shock whether the module is connected
or disconnected.
The shock hazard increases as modules
are connected in parallel, producing
higher current, and as modules are
connected in series, producing higher
voltage.
The installer assumes the risk of all
personal injury or property damage that
might occur during installation and
handling of modules.
To avoid injury or damage:
©
Cover the entire front and back
surface of the bifacial modules with
a dense, opaque material such as a
cardboard box or heavy cloth.
Work only in dry conditions, with
dry modules and tools.
Do not stand or step on a module.
Do not drop a module.
Do not break the glass surfaces of a
module.
Do
unauthorized
installation site or storage area of
for
loss,
modules.
Completely
installation,
according
codes.
Do not disassemble the module, or
remove any part installed by the
manufacturer.
Do not open the cover of the
junction box.
Wear suitable protection (gloves,
clothes,
contact with 30V DC or greater.
constitute
an
Carry a module by its' frame with
two or more people.
Do not carry a module by its wires
or junction box.
gloves.
Do not drop or place heavy items on
the surfaces of a module (such as
tools).
Check
components (inverters, wires, racks,
balance of system materials, etc.)
are mechanically and electrically
licensed
compatible.
Do not install the module where
flammable gases or vapors are
present.
Never leave a module unsupported
or unsecured.
Do
maintain
the
modules.
PV
modules
Do
sunlight on a module by mirror,
Fresnel lens, magnification, etc.
not
allow
children
persons
near
ground
all
modules
to
applicable
electric
etc.)
to
prevent
Wear non-slip
that
all
other
system
not
use
or
install
broken
not
artificially
concentrate
1
Do not touch the junction box
terminals.
Do not change the wiring of bypass
diodes.
Do
not
touch
unnecessarily. The glass surface
and frames get hot. There is a risk of
burn.
CAUTIONS
Use a module for its intended
purpose only.
Do not treat any portion of the
module with paint or adhesives, to
avoid
damage
inoperable conditions, or reducing
the module's functionality.
HIT Double modules have bifacial
performance.
produce power from both surfaces
of the module at the same time and
may generate up to 30% more
output power than its' STC rated
value. Refer to Figure 5 for these
output electrical characteristics.
and
This additional power depends upon
the
the level of incident light irradiance
(albedo) available to the back side of
the module, and can be increased or
decreased
depending
characteristics, installation design,
weather, etc.
Treat the back side of the module
the same as the front side and avoid
objects that directly shade the solar
cells.
Refer
installation" section.
direct
GENERAL SAFETY
Follow all permission, installation and
inspection requirements.
Before installing modules, contact the
appropriate authorities to determine
permissions, installation and inspection
requirements that apply to your site
and installation.
Electrically ground modules for all
systems
of
otherwise specified, it is recommended
that requirements of the latest National
Electrical Code (USA) or Canadian
Electric
Code
national
or
standards be followed. Refer to "Earth
Ground Wiring" section.
Check applicable building codes to
ensure
that
structure (roof, facade, support, etc.)
where the modules are being installed
has enough strength.
For modules mounted on roofs, special
construction or structures may be
a
PV
module
to
the
module,
These
modules
upon
site
to
"Notes
on
any
voltage.
If
not
(Canada)
or
other
international
electrical
the
construction
or

Advertisement

loading

Summary of Contents for Panasonic HIT Double Photovoltaic modules

  • Page 1 To avoid injury or damage: module with paint or adhesives, to © avoid damage module, Thank you for choosing Panasonic HIT • Cover the entire front and back Double PV modules. With proper operation inoperable conditions, or reducing surface of the bifacial modules with and maintenance, Panasonic modules will the module’s functionality.
  • Page 2: Installation Reference

    This (VBHBxxxDA03) modules section contains electrical and mechanical specifications needed before using your Solar Module Panasonic PV modules. • Modules should be firmly fixed in place φ8 in a manner suitable to withstand all expected loads, including wind and snow loads.
  • Page 3: Specifications

    General Installation Manual © Apr 2012, SANYO Electric Co., Ltd. All Rights Reserved within the following conditions: 1,440Pa (30PSF) in a static state on seven (7) or fewer. If connecting eight Terrestrial applications only—no outer the module surface. (8) modules in series, check local space use.
  • Page 4 General Installation Manual © Apr 2012, SANYO Electric Co., Ltd. All Rights Reserved means depends upon screw threads placed between the wire and the • Use Tyco Electronics 1954381-2 as two or more screws or two full threads module frame. grounding clip.
  • Page 5: Maintenance

    If you need electrical or mechanical inspection maintenance, it recommended to have a licensed authorized professional carry out the inspection or maintenance to avoid the hazards of electric shock or injury. further information, please visit http://panasonic.net/energy/solar/ or contact your SANYO Authorized Representative.
  • Page 6 General Installation Manual © Apr 2012, SANYO Electric Co., Ltd. All Rights Reserved Connector Cable Cable Connector Plug Plug negative ( - ) positive ( + ) Figure 3-1. Configuration of Junction Box for VBHBxxxDA03 Glass Glass Length Star washer (Stainless steel) (not less than 1.024”(26 mm) Flat washer (Stainless steel) not more than 1.26”(32 mm))
  • Page 7 General Installation Manual © Apr 2012, SANYO Electric Co., Ltd. All Rights Reserved Set screw Grounding Clip (Stainless steel) TYCO 1954381-2(SolKlip) Grounding lug Copper wire [Top view] [Top view] Copper wire Frame Glass Frame Glass Nut (Stainless steel) Nut (Stainless steel) [Section] [Section] Bolt (Stainless steel)
  • Page 8 General Installation Manual © Apr 2012, SANYO Electric Co., Ltd. All Rights Reserved (a) Long frame and Short frame (Not J-Box side) Glass side of the module 0.7” 0.4” Drill in this area 3’ 3” (b) Short frame (J-Box side) Glass side of the module 0.7”...
  • Page 9 General Installation Manual © Apr 2012, SANYO Electric Co., Ltd. All Rights Reserved SPECIFICATIONS HIT D ouble Series (VBHBxxxDA03, VBHBxxxDA03B) Specifications Cell Number in Series [Pieces] Cell Type HIT* (hybrid of amorphous and monocrystalline silicon) Maximum System Voltage [V] Bypass Diodes 4 Bypass Diodes Maximum Series Fuse (A) Panel Area...
  • Page 10 General Installation Manual © Apr 2012, SANYO Electric Co., Ltd. All Rights Reserved Electrical Specifications Including Bifacial Effect Specifications Including Backside Irradiation Rated Contribution in Isc as a Percent of STC Model HIT Doble 195 Maxim um Power (Pmax) Maxim um Power Voltage (Vpm) 55.8 55.8 55.8...