Elation SIXPAR 100IP User Manual
Hide thumbs Also See for SIXPAR 100IP:

Advertisement

SIXPAR 100IP™
user manual
 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIXPAR 100IP and is the answer not in the manual?

Questions and answers

Summary of Contents for Elation SIXPAR 100IP

  • Page 1 SIXPAR 100IP™ user manual    ...
  • Page 2 Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040 323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com Elation Professional B.V.
  • Page 3: Table Of Contents

    C O N T E N T S General Information Warranty Safety Instructions General Guidelines Fixture Overview Fixture Installation Understanding DMX Fixture Menu DMX Channel Functions And Values Cleaning and Maintenance Technical Specifications Optional Accessories SIXPAR 100IP™ User Manual ver 1...
  • Page 4: General Information

    Congratulations, you have just purchased one of the most innovative and ™ reliable ArtNet to DMX converter on the market today! The SIXPAR 100IP been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit.
  • Page 5 You may also visit us on the web at www.elationlighting.com any comments or suggestions. For service related issue please contact Elation Professional®. ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST...
  • Page 6 SIXPAR 100IP™ User Manual ver 1...
  • Page 7: Warranty

    No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional® shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof.
  • Page 8: Safety Instructions

    Do not operate this fixture if the power cord has become frayed, crimped and/or damaged. If • the power cord is damaged, replace it immediately with a new one of similar power rating. SIXPAR 100IP™ User Manual ver 1...
  • Page 9: General Guidelines

    • Use the original packaging and materials to transport the fixture in for service. DO NOT TOUCH the housing bare-hand during its operation. Turn OFF the power • and allow approximately 15 minutes for the fixture to cool down before replacing or serving. SIXPAR 100IP™ User Manual ver 1...
  • Page 10: Fixture Overview

    . e l a t i o n l i g h t i n g . c o m F I X T U R E O V E R V I E W MODE Button UP Button DOWN Button ENTER Button Power IN DMX IN DMX Out Power OUT SIXPAR 100IP™ User Manual ver 1...
  • Page 11: Fixture Installation

    Dual Yoke / Floor Stand. When mounting this fixture to truss be sure to secure an appropriately rated clamp using an M10 screw fitted through the center hole of the Dual Yoke / Floor Stand. SIXPAR 100IP™ User Manual ver 1...
  • Page 12 . e l a t i o n l i g h t i n g . c o m SECURING ™ Regardless of the rigging option you choose for your SIXPAR 100IP always be sure to secure your fixture with a safety cable.
  • Page 13: Understanding Dmx

    Your fixture and your DMX controller require a standard 3pin or 5pin XLR connector for data input and data output (see figure below). Also, remember that a DMX line must be daisy chained and cannot be split. SIXPAR 100IP™ User Manual ver 1...
  • Page 14 Connect the provided XLR cable to the female XLR output of your controller and the ™ other side to the male XLR input of the SIXPAR 100IP . The diagram below illustrates a typical DMX-512 connection when the fixture is in the 12 Channel Mode. You can chain multiple panels together through serial linking.
  • Page 15 ™ In the case of the SIXPAR 100IP , when in the 12 Channel Mode you should set the starting DMX address of the first unit to 1, the second unit to 13 (1 + 12), the third unit to 25 (13 + 12), and so on.
  • Page 16: Fixture Menu

    . e l a t i o n l i g h t i n g . c o m F I X T U R E M E N U ON-BOARD SYSTEM MENU The SIXPAR 100IP™ comes with an easy to navigate system menu. The next sections will cover how to access each menu function.
  • Page 17 Adjust SPEED 01 SLOW - 99 FAST S00-99 Adjust STROBE SPEED 00 SLOW (0.1Hz) - 99 FAST (20Hz) DimCurve Standard, Stage, TV, Architec, Theatre Set Dimming Curve Blackout NO Output NO DMX Hold Hold Last Setting Fade Fade SIXPAR 100IP™ User Manual ver 1...
  • Page 18 . e l a t i o n l i g h t i n g . c o m DIMMING CURVES The DimCurve menu allows you to select one of the following preset dimming curves: Standard, Stage, TV, Architec, or Theatre. (See diagram below for more details) Dimmer SIXPAR 100IP™ User Manual ver 1...
  • Page 19: Dmx Channel Functions And Values

    Strobe Effect SLOW to FAST 96-127 LED ON (NO STROBE) 128-159 Strobe Pulse Effect In Sequences SLOW to FAST 160-191 LED ON (NO STROBE) 192-223 Random Strobe Effect SLOW to FAST 224-255 LED ON (NO STROBE) SIXPAR 100IP™ User Manual ver 1...
  • Page 20 GREEN + BLUE + WHITE 132-135 GREEN + BLUE + AMBER 136-139 GREEN + BLUE + UV 140-143 GREEN + WHITE + AMBER 144-147 GREEN + WHITE + UV 148-151 GREEN + AMBER + UV SIXPAR 100IP™ User Manual ver 1...
  • Page 21 Color Fade Chase 81-255 NO Function COLOR CHASE MACROS SPEED 00-255 Chase Speed of CHANNEL 10 - SLOW to FAST DIMMING MODES 0-20 STANDARD 21-40 STAGE 41-60 61-80 ARCHITECTURAL 81-100 THEATER 101-255 NO Function SIXPAR 100IP™ User Manual ver 1...
  • Page 22: Cleaning And Maintenance

    Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer.
  • Page 23: Technical Specifications

    CE | IP65** **Optional Corrosion-Resistant Coating may be available for this fixture. Please consult an Elation sales representative for details. Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
  • Page 24: Photometric Data

    . e l a t i o n l i g h t i n g . c o m PHOTOMETRIC DATA DIMENSIONAL DRAWINGS Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. SIXPAR 100IP™ User Manual ver 1...
  • Page 25: Optional Accessories

    65.6 ft. (20m) IP Power Link Cable SIXPAR/DIAC Data IN IP Adapter Cable SIXPAR/DOAC Data OUT IP Adapter Cable SIXPAR/PIAC Power IN IP Adapter Cable SIXPAR/POAC Power OUT Adapter Cable SIXPAR/TERMINATOR DMX Terminator End Cap SIXPAR 100IP™ User Manual ver 1...

This manual is also suitable for:

Sixpar 100