User Manual www.deltasecurity.cn GSM Alarm System All rights reserved by Delta Security Co., Ltd...
Page 2
Dear Clients, Thank you for using our GSM Alarm System. We are committed to giving you the best home security available today and we take the safety of your home and family seriously. Our system allows you to instantly arm and disarm your property, instantly change your system settings and find out your system status and much more.
Page 3
Cautions To avoid personal inquiry and the damage to the product, please take the following preventive measures. ● Input Voltage: DC12V 1A. Do not use power adapter with different specifications. ● Use the professional tools for assembling to avoid the damage to the main panel ●...
1. Alarm Host Diagram GSM signal indicator: Flash once every second when no SIM card or searching network; Flashes once every 3 seconds when GSM signal is in normal. Arm: Arm the system by panel has a 60s’ delay (Default factory set). www.deltasecurity.cn Home mode: Enter into home mode.
Start Up a. Insert a SIM card Insert a SIM card in direction as above pictures indicate. Push until you hear a click of spring. Do not insert or take out the SIM card when the main unit panel is powered on. b.
3. Operation Instructions Initiating image: MUTE Silent the keyboard VOL+ Volume up VOL- Volume down MENU Main menu Function Key: www.deltasecurity.cn BACK Return to previous menu Volume up DOWN Volume down ENTER Main menu SAVE Save up the settings ABC/abc/123 Switch the input method DELETE Delete the inputs...
Start to Set Before doing any settings, we need enter into setting status or enter into “Program” menu. Please follow those steps. Each step within this manual has to be followed with “Enter” to confirm your operation. Disarm the system----Press “Menu” ----Select “Program” ----Input password (default value: 888888) Start Menu www.deltasecurity.cn...
Page 8
Add a Phone number/SMS number a. Add a phone number into system Enter into “program” menu---Select “Phone Numbers” and Enter---Select “Add” and press Enter---Input numbers on the keyboard and press Save. The system can store 6 phone numbers, and each phone number is equal to or not longer than 22 digits. b.
Remote Control In order to protect people on life-threaten occasions, to press SOS button on remote controller will not trigger alarm, but system will make emergency call and send SMS. a. Add a remote control into system This system can register with 8 remote controllers and each of them can be renamed. Besides, the name of remote control can be recorded.
Wireless Sensors a. Add a sensor into system, Rename&Record The system is able to connect with 50 wireless accessories not including remote control, RFID tags and wireless siren. Here are steps. Enter into “Program” menu---“Sensors”---“Add”---Trigger sensor, remit a signal to panel---Input the name of the sensor on the keyboard and “Save”---Recording the sensor name in 5 seconds.
d. Edit Sensor Each sensor within the system can be edited with different features and functions. Identify the sensor’s name by either way of above two methods, press “Enter” to confirm. 【Edit the Zone Name】: Sensor name has to be controlled within 25 letters. When panel receives an intrusion signal from this sensor, panel will report all your programmed www.deltasecurity.cn information to owner by SMS.
Page 12
RFID tags a. Add a RFID tag into your system The system can accept up to 8 RFID tags. Enter into “Program” and press “Enter”---Select “RFID” and press “Enter”—Select “Add”---Hold your RFID tag and make it close to RFID reading area as bellowing photo.
Wireless Siren a. Add a wireless siren into system The system can register 3 wireless sirens at most. Here are the operation steps. Enter into “Program”---“Wireless Sirens”---“Add”, then you will see a default name “Sirens 1” on the LCD screen, press “Enter” as bellowing picture indicates. Then system will imply that “Put Siren in Setting Mode”.
Page 14
Turn on/off the Siren “Program”---“Wireless Sirens”---“Siren Enable”---Select “Yes” to turn on siren, Select “No” to turn off siren. Siren Sound Duration Set siren sound duration from 1~180 seconds. “Program”---“Wireless Sirens”---“Duration”---Input a number between 1 to 180 and “Save” Arm/Disarm wireless siren notification “Program”---“Wireless Sirens”---“Arm/Disarm Tone”---Select “Yes”...
Page 15
Bluetooth Communication between panel and cell There are two way to connect the cell with system via an APP, Bluetooth and GSM network. Within Bluetooth range, we can use Bluetooth to realize basic control of the system. Out of Bluetooth range, App will choose GSM network automatically. 8 cell numbers can be paired with system via Bluetooth.
Page 16
How to find out Bluetooth Address of your alarm panel? Disarm the alarm system---“Program”---“System About”---“BlueTooth Mac” and press “Enter”, then system will generate a BlueTooth Mac/Address automatically as belowing picture. The BlueTooth Mac is random and unique. Input the same address on Cell phone and save. And then, Input the correct password of host (default: 888888) on cell and save.
Monitoring Center The alarm system use standard Ademco Contact ID to connect with monitoring center. Get a telephone number and User ID from your monitoring service provider and input them into the alarm system. And make sure turn on the upload alarm data and upload ARM/Disarm data.
Outgoing Message In event of intrusion, this message will be sent to preset SMS numbers. If you also record the message, the record will be played to preset Phone Numbers before the emergency call is answered. a. Edit the message Disarm the system enter into “Menu”---“Program”---Page down and select “Outgoing Message”---“...
Page 19
Timely arm/disarm system The menu can realize system automatically arm/disarm itself on a setting time. How to set the automatic system arm/disarm time? Enter into “Menu”---“Program”---“Timely Arm/Disarm”---“Enable”---“Set Arm Time”---Input an automatic system arming time in 24 hour format (HH:MM) and press “Save”. The preset system arming time should be any value between 00:00 and 23:59.
Door/Window Open Reminding With this feature, the system cannot be armed if any single one of door/window sensors is not closed. The system will remind you to keep all the windows and doors closed before leaving the house and arming the system. Here are the setting steps. Disarm alarm system...
Restore factory set It may lead to the lost of all the customized system settings. Be careful to operate it unless you have to. Enter into “Menu”---“Program”---“System Settings”---“Factory Reset”---Then you will see there are two options, “Restore Defaults” and “Format System” Restore defaults: Except Remote controller, Sensors, Wireless Siren, RFID tags and Bluetooth communication, the rest of system settings are returned to default status.
Hardware Test This auto trouble-shooting feature enables users to rule out the failed parts by themselves in event of system failure. Disarm the system and enter into “Menu”---“Program”---“Hardware test”, page up and down, we will see whole menu. www.deltasecurity.cn 【Lcd Test 】: Test whether the LCD screen can work normally 【Led Test】: Test whether Led Lights and the backlights can work normally 【Key Test】: Test whether the keyboard can work normally 【RFID Test】: Test whether the RFID Reader area can work normally...
Page 23
Number Key 2: to disarm the system Number key 3: to monitoring and listening to the alarm site for 30 seconds. If continuous monitoring is required, press”3” key again to extend time for 30s. All rights reserved by Delta Security CO.,Ltd...
Need help?
Do you have a question about the GSM Alarm System and is the answer not in the manual?
Questions and answers