Arming/Disarming
Code definition:
Addresses 062, 064, 066:
Addresses 068, 070, 072:
Addresses 074, 076, 078:
When a code is activated at both addresses (062-066 and 068-072), it can do the following:
• The code can fully arm the system. If the code is entered when systems "A" and "B" are disarmed, it
will completely arm the system.
• The code can fully disarm the system. If the code is entered when system "A" and "B" zones are
armed, it will completely disarm the system.
• When the system is partially armed (i.e. only System "A" or "B" is armed) entering this code will arm
the other system.
• The code can be used to selectively arm/disarm System "A" or System "B" zones.
Enter [11] + code to arm/disarm System "A" zones.
Enter [12] + code to arm/disarm System "B" zones.
Note:
Codes that are not selected at either address are disabled.
The master code can always access both systems and bypass zones.
• System "A" codes can stop sirens coming from System "B" zones (and vice versa), but will not dis-
arm the other system.
• It is not possible to arm one system during the other system's exit delay.
Note:
When partitioning is not activated, (address 086, key [8] "off"):
Addresses 062, 064, 066 determines which access codes can activate "stay" arming.
Addresses 068, 070, 072 determines which access codes can activate "away" arming.
Addresses 074, 076, 078 determines which access codes can "bypass" zones.
Partition "on" (Address 086, key [8] "on")
Designates access codes that arm System "A" zones.
Designates access codes that arm System "B" zones.
Designates access codes that can "bypass" zones
26