230 V/50 Hz mains. Do not use the inverter in autonomous power systems. Do not use the inverter in vehicles. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 8
Remote control of AC power in connection with PLATINUM PowerCommander, PLATINUM WebMaster and a control device on the mains supply side. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
PLATINUM inverter with protector preassembled in Power Block protective housing with protective cover and protective grate Installation and operating manual Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 10
Screw DIN 580 M10 eyebolts into threaded holes 1 on inverter. Fasten lifting gear on eyebolts. Eyebolts are not included in delivery. Note Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 11
Use wooden protection elements 2 for carrying. Take inverter to installation site. On installation site: Unscrew wooden protection elements 2 from inverter. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 12
Take inverter to installation site on transport pallet 1. Put transport pallet with inverter on even ground. Remove plastic protective packaging. Put inverter on intended installation site. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Caution Avoid dust formation with electrically conductive dust particles. DIEHL AKO advises against installing the inverter in living spaces. Note Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 14
For versions with protector, prior to installation of inverter: Hold protector 1 on bottom side and pull away from inverter. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 15
Observe a minimum distance of 50 cm between inverter and ceiling. Drill the mounting holes and insert the screw anchors. Bolt down mounting fixture 1. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 16
Verify that minimum distances are kept (see Fig. 6). Verify that the inverter is hanging in the mounting fixture correctly. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 17
Put inverter in intended position. Secure inverter against toppling over and shifting with screws in base of Power Block protective housing TL Large 1. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Use exclusively DC cable connectors and DC receptacles of the same type and manufacturer. Caution Make sure that cable connector in latched in socket correctly. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 19
For free-standing devices, the possibilities for cable routing through Power Block protective housing TL Large are as follows: from front from below from back Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 20
(4) Switch knob DC disconnector (5) Cover of AC voltage connection (6) Bushing for AC voltage cable (7) Type plate Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 21
Open cover of AC voltage connection area 2. Put cable through bushing for AC voltage connection cable. Suitable for cable diameters between 12 and 21 mm. Note Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 22
Clamp suitable for single-wire (rigid) lines with line diameter of 2.5 to Note 10 mm or multi-wire (flexible) lines with line diameter of 2.5 to 6 mm Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 23
Fixate AC cables with screw connection of bushing for AC voltage connection cable. Close cover of AC voltage connection area. Fasten cover with screws. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 24
Make sure that cable connector in latched in socket correctly. Put protective caps on unused plug connectors. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 25
(5) PC interface to EIA232 (exclusively for service purposes) It is possible to connect up to 50 PLATINUM inverters. Note Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 26
For incoming line pair: connector 9 connector 10 For outgoing line pair: connector 11 connector 12 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 27
(see Fig. 12). For lines without RJ45 plugs, connect lines A and B in RJ45 plugs on connectors A and B. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 28
Setting: see menu Settings function Alarm contact Only use safety extra low voltage (SELV) of max. 24 V as supply voltage. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 29
Put upper part of protector 2 on upper fixture 1 and slightly push down housing. Slide bottom part of protector in lower fixture 3. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 30
Push protective cover to the right. Close protective cover. It is possible to lock the protective cover as a protection from impermissible access. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 31
1 in bottom of cover and in Power Block protective housing. Secure cable rope or similar with lock. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 32
If parameters of the inverter have been adapted to special Note requirements of the energy supplier, this is indicated on the start screen. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
The inverter is supplied with power. Configuration through the following dialogs. Initial startup Function Start configuration process with this inverter. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 34
When the network scan is completed, the display shows the number of detected bus participants. In case of a single inverter, the display shows 01. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 35
2 and the right-hand one no. 3. The following screen is not displayed if only one inverter is Note configured. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 36
1, which is shown on the display. When the OK key was pressed at the second inverter, this inverter is allocated no. 2, etc.. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010...
Page 37
To select country code: Select desired country. Press OK key. The inverter automatically transmits the country code setting to all network participants. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 38
Note inverter can be changed. Date Function Increment or decrement present digit. Select next or previous digit. Accept date setting. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 39
(if available). After the data transmission, the inverter will show the menu Time settings (see 7.6 Settings). Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Display and operation are confined to the replaced inverters. All other inverters show the start screen. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 41
Select desired device number. Press OK key. Inverter does another network scan. The inverter automatically transmits the device numbers to all other inverters. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 42
Inverter shows device number of the replaced device in the lower left corner. After device replacement: Set date and time. Reassign numbers Reassign numbers see 6.1 Initial startup of inverter. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
DC disconnector to minimize wear and tear of the contacts. Fig. 19 DC disconnector (1) DC disconnector Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
(5) LED green (6) Date (7) OK key (8) Navigation keys (9) ESC key (10)Device number (11)Scroll arrows vertical (12)Day Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 45
Date display in formats DD.MM.YY, MM.DD.YY oder YY.MM.DD. Adjustable in menu Time settings. Keys The functions of the keys are indicated in the tables under the illustrations. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Main Menu Function Navigate within menu. Call up selected menu. To return to main menu from all menus: Press ESC repeatedly. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Horizontal axis in graphic: time scale (e. g. hours of a day) Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 48
Show current phase 1, phase 2 or phase 3: List of current electrical values for DC and AC side. Separate AC currents for all three phases. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 49
Back to Main Menu. Function Call up screen Current Phase 2. Call up screen Operating Display. Back to Main Menu. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 50
The values displayed by the inverter may differ from the readings of Note calibrated electricity meters. (1) Physical values (2) Graphic of physical value Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 51
Table: For the display period TODAY, the current power value is displayed. For all other periods, the maximum value is displayed. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 52
In the menu Time settings, the following settings are possible: Date Time Date format Daylight saving time Function Navigate within menu. Back to menu Settings. Call up selected menu. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 53
To accept time setting: Select SELECT. Press OK key. The inverter automatically shares the new time setting with all network participants. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 54
Manual setting of daylight saving time required. AUTOMATIC Inverter sets daylight saving time automatically, depending on set country and calendar. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 55
Back to menu Settings. Accept alarm volume setting. The inverter automatically transfers the alarm volume setting to all network participants. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 56
(NO contact) is constantly closed until the error is remedied. TEST Close alarm contact temporarily while selecting a menu item. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 57
After the input is finished, the value is automatically transferred to all other inverters. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 58
Back to menu Settings. RESET Set energy meter to 0. Select BACK or RESET. Confirm selection. Back to menu Settings. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 59
Shows feed data of the inverter since the startup. Resetting is not possible. METER 2 Shows feed data of the inverter since the latest reset of meter 2. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 60
PLATINUM PV-Monitor, PLATINUM ViewMaster and PLATINUM Webmaster). NO. OF INVERTERS Shows the number of inverters in the network. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 61
When contacting the PLATINUM service, have the serial number Note ready. After changing the inverter network parameters, the display indicates USER-DEFINED NETWORK MONITORING.. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 62
Shows the inverter firmware version. HARDWARE Shows the inverter hardware version. EIA485 Shows the data bus software version. Shows version of bootloader software. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Destruction of invterter due to fatal errors! Switch off AC. Switch off DC. If available: Warning Set DC disconnector to 0. Notify PLATINUM service. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 64
Inverter switches off acoustic alarm. Press key ESC again. Inverter shows start screen. Red LED flashes as long as the error persists. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 65
Until the error is resolved: The inverter displays the screen Non-blocking error. The red LED is flashing. Delete error display with key ESC. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Go to menu Settings and select menu item Time setting and press buttons for about 3 s. Function Navigate within menu. Return to standard display. Call up selected menu. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 67
Explanations about the events see 12.1 Table of events. Have the event code and the serial number ready when contacting the PLATINUM service. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 68
Screen Version shows information on inverter type. Function Return to menu Service. Call up screen Frequency Limits. Back to menu Main Menu. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 69
Function Call up screen Frequency Limits. Call up screen Mains Quality. Back to menu Main Menu. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 70
Function Call up screen Mains Quality. Call up screen Fault Current. Back to menu Main Menu. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 71
AC and DC powers AC and DC currents Function Call up screen Fault Current. Call up screen Version. Back to menu Main Menu. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 72
If one inverter module fails, the inverter limits the AC power of the other modules to the set unbalanced load. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 73
Select next or previous digit. Back to menu Main Menu. Accept setting. Range of values: 10 s to 9,999 s Factory setting: 300 s Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 74
A reconfiguration of the country is only possible within the first four Note hours after the connection. Afterwards, this menu item is blocked. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 75
To change the inverter numbering after startup: Select Reconfiguration in the Service Menu. Change inverter numbers see 6.1 Initial startup of inverter, subsection Allocating inverter numbers. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 76
Disconnect in the following order: 1. Remove cable from terminal strip on AC side. 2. Pull DC plug. Maintenance The inverter is maintenance-free. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 77
In a dusty environment: Check fan and cooling elements regularly and clean them if necessary. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Remove cable from AC terminal. Set DC disconnector to 0 and pull plug connector of input voltage (DC side). Disconnect remaining connectors as required. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 79
Pack the inverter in the packaging of the replacement. If a single inverter is returned: Demand additional packaging from Diehl-Controls or reuse it. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 80
Put inverter in bottom part of packaging 3. Put upper part of packaging 1 on inverter. Secure the box with packing straps. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 81
Fig. 22 Packing up the free-standing device (1) Transport pallet Put transport pallet 1 on even ground. Put inverter on transport pallet 1. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Provide the service with the error code if required. Fatal Call Service. system error Provide the service with the error code if required. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 83
(voltage peak) Have all bondings and fuses between the consumer’s terminal and the inverter checked. Have the mains quality checked. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 84
Diagnosis support during Provide the service with the error code if required. service max. AC exceeded Check AC side for short circuit. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
DIN EN 61 000-3-3: 1994 / A2: 2005 DIN EN 61 000-3-11: 2001-04 DIN EN 61 000-6-2: 2006-03 DIN EN 61 000-6-3: 2007-09 Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Maximum degree of efficiency 97.3% 97.4% 97.7% 98.0% European efficiency 96.8% 96.8% 97.3% 97.6% Weight 81 kg 84 kg 87 kg 87 kg Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 87
Transformerless, DIVE, RAC-MPP, ENS according to VDE 0126-1-1 Technical data apply to maximum height above MSL of 2,000 m. Note Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Klaus Frehner CEO Photovoltaics Phone: +49 (0) 7522 73 0 Fax: +49 (0) 7522 73 300 Mailto: info@diehlako.com www.diehlako.de Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 89
Warranted Product at the Warranted User’s premises (Warranty Period). This Warranty Period ends not later than Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 90
Any claims based on this manufacturer’s warranty expire 6 months after occurrence of the fault, but not later than 3 months after the end of the Warranty Period. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 91
(iv) the third licencee declares to Diehl AKO its agreement to these conditions of guarantee in written form. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 92
The exclusive place of jurisdiction in case of any conflict arising from, or in connection with this manufacturer’s warranty, is Wangen im Allgäu/FRG. Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB...
Page 94
Pfannerstraße 75 D-88239 Wangen Fon: +49 7522 73 700 Fax: +49 7522 73 710 Mailto: platinum@diehlako.com www.diehlako.com S e r v i c e Diehl AKO Stiftung & Co. KG Pfannerstraße 75 Tel.:+49 7522 73 777 Mailto:service.platinum@diehlako.com w w w . d i e h l a k o . c o m...
Need help?
Do you have a question about the 22000 tl and is the answer not in the manual?
Questions and answers