Oki Data CONFIDENTIAL
(1) How to select the menu items
XXXX
Menu items can be selected by long pressing of [4] or [ ], or by short pressing of [2] or [8].
LEVEL0
XXXX
Menu items can be entered by pressing of [6] or [4], and can be selected by pressing of [2] or [8].
[4]
[8]
Respective voltages
display during print
Transfer (TR) voltage (1)
[2]
Transfer (TR) voltage (2)
Charge (CH) voltage
Supply (SB) voltage
Develop (DB) voltage
Environment level
Develop (SB) voltage
(Front and back)
Transfer (TR) voltage (3)
44871001TH Rev.6
Engine status display
Heater information
Environment information
CH, DB
Fuser,
Setup table number
TR
Setup table number
TR off
Setup table number
[8]
Toner sensor monitor
K toner sensor status
[2]
monitor display
[8]
Toner pulse count
monitor
[2]
Toner pulse count
status monitor display
[ ]
[8]
Toner TAG noise test
monitor
[2]
Tag serial No
(Last four digits)
Noise detection count
display.
Error detection count
display.
6. MAINTENANCE MENUS
Error details
Error code display and
others
Motor controls
evaluation function
Main motor constant
speed timer value,
Environment
temperature
Fuser motor
constant speed timer
value, Fuse target
temperature
6-14
Need help?
Do you have a question about the MB461 and is the answer not in the manual?
Questions and answers