SOMFY ROLLIXO RTS Installation Manual

SOMFY ROLLIXO RTS Installation Manual

Hide thumbs Also See for ROLLIXO RTS:
Table of Contents

Advertisement

1
2
3
4
Prog
STOP
ROLLIXO RTS
Installation
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ROLLIXO RTS and is the answer not in the manual?

Questions and answers

Summary of Contents for SOMFY ROLLIXO RTS

  • Page 1 Prog STOP ROLLIXO RTS Installation...
  • Page 2: Table Of Contents

    Clearing a remote control Clearing all remote controls Clearing safety edge transmitters..........................19 Locking the programming buttons ..........................19 Diagnostics ...................................19 Receiver Resistive safety edge transmitter (ESE) Optical safety edge transmitter (OSE) technical data ................................21 Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 3: General Information

    This guide describes how to install, commission and operate this product. Follow all the instructions as incorrect installation can lead to serious injury. Any use outside the sphere of application specified by Somfy is forbidden. This invalidates the warranty and discharges Somfy of all liability, as does any failure to comply with the instructions given herein.
  • Page 4: Description Of The Rollixo Receiver

    Cell indicator light Information on the status of the cells space requirements standard installation diagram 182,7 60,6 Motor 157,7 fall protection Receiver safety edge transmitter safety edge Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 5: Installation

    [1]. Remove the integrated light bulb. [2]. Unscrew and remove the receiver cover. [3]. Hold the receiver against the wall (lighting facing upwards) and line up with drilled holes. [4]. Mount the receiver onto the wall. Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 6: Fall Protection Motor Wiring

    If no fall protection is connected, it is essential to create the bridge between terminals 5 and 6 of the receiver (with the shunt provided). Stop Safety Edge Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 7: Connecting The Receiver To The Mains Power Supply

    If indicator light 2 comes on permanently, the safety edge has not been detected by the receiver (radio safety edge transmitter not yet memorised or the wired safety edge is still Prog STOP not connected). Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 8: Checking The Direction Of Rotation Of The Motor And Adjusting The Motor End Limits

    [5]. Press the motor's upper end limit push-button. [6]. Press button to position the garage door in the lower position. Prog STOP Adjust the low position with buttons and . Prog STOP Prog STOP Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 9 Prog until the motor's up and down movement occurs to enter motor adjustment mode. STOP Prog STOP Prog Prog STOP Indicator light 1 goes out. Prog STOP Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 10: Installing And Commissioning A Radio Optical Safety Edge

    To function correctly, this solution requires the installation of a set of magnets on the runner TOP magnet Safety edge transmitter mounting plate BOTTOM magnet [1]. Press button to position the garage door in the upper position.  E nsurethesafetyedgetransmitterisnotfixedtoitsplate. Prog STOP Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 11: Installing The Safety Edge And Its Transmitter

    Do not press the safety edge during the magnet recognition procedure. Prog Carry out two whole cycles (opening then closing) using buttons and . STOP Prog STOP Prog STOP Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 12: Checking Operation Of The Receiver

    The alarm is triggered for 2 minutes if the door is fully closed and raised manually. No movement of the door is possible when the alarm is sounding. When the alarm sounds, press a button on a remote control memorised in the receiver to stop it. The alarm can only be stopped with a memorised remote control. Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 13: Connecting Additional Devices

    Activated Deactivated Choice of cell type Photoelectric Reflex photocell 2-second orange light warning Activated Deactivated Choice of wired safety edge type Resistive Optical Alarm operation Activated Deactivated STOP Prog Do not use Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 14: Description Of The Various Additional Devices

    It is compulsory to install photoelectric cells if: - the automatic control device is being controlled remotely (user unable to see it), - automatic closure is activated. 24V Cell Sec Cell Test 24V dc Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 15 KeySwitch If a wired safety edge replaces a radio safety edge, the radio safety edge transmitter must be cleared (see page 18) to ensure the wired safety edge is taken into account. Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 16 STOP The alarm triggers briefly to indicate that it is activated. STOP Prog • optional: lower magnet A lower magnet may be installed if the alarm sounds erratically (see page 9). Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 17: Advanced Parameter Setting

    [1]. Run the timer by pressing and holding down the T button for 2 seconds. Indicator light flashes rapidly. [2]. Stop the timer by briefly pressing the T button when the desired time delay is obtained. Indicator light flashes slowly or comes on permanently. Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 18: Memorising The Remote Controls

    This operation must be carried out close to the receiver. With an Rts keygo With a 3-button remote control < 1s A = remote control "source" already memorised B = remote control "target" to be memorised Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 19: Memorising Safety Edge Transmitters

    Prog All memorised remote controls will be cleared. Prog Prog Prog Prog Prog Press and hold down for 7 seconds Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 20: Clearing Safety Edge Transmitters

    (when fall protection is connected to the shared motor terminal) Activated motor thermal Wait around 10 minutes. protection Waiting for motor Set the motor end limits (see pages 7 and 8). adjustment Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 21: Resistive Safety Edge Transmitter (Ese)

    The transmitter indicator light will come on: If the indicator light flashes: 6 times → the safety edge is faulty (short-circuit). 8 times → the safety edge has not been correctly lengthened (open circuit). Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 22: Optical Safety Edge Transmitter (Ose)

    Up-Stop-Down buttons in the control panel Automatic closing mode Downgraded operation mode control Automatically activated when lowering if a fault is detected on a safety device Maintenance assistance Real time status with 5 indicator lights Copyright © 2012 Somfy SAS. All rights reserved...
  • Page 23 Somfy Ltd Moorfield Road Yeadon Leeds West Yorkshire LS19 7BN T. 0113 391 3030 www.somfy.co.uk www.rollixo.co.uk...

Table of Contents

Save PDF