Product Diagram; Characteristics - Bosch HydroPower 10H Installation & Owners Manual

Table of Contents

Advertisement

Product Diagram

Product Characteristics
Model
Inlet Gas Pressure NG
Inlet Gas Pressure LPG
Burner Gas Pressure NG
Burner Gas Pressure LPG
NHGC
Maximum Water flow at 50°C rise
Maximum Water flow at 25°C rise
Minimum water flow rate
Note:
Your water heating appliance requires a hot water flow rate of 3.2 litres per minute
and above to operate.
Water fixtures with a flow rate of 7.5 litres per minute or higher are recommended.
Your water heating appliance is not recommended for use on Solar, Spa or
recirculation systems.
1. Main Cover
2. Inspection Window
3. Cold Water Inlet
4. Gas Inlet
5. Hot Water Outlet
6. Mounting Point
7. Horizontal Flue
A
405mm
845mm
405mm
845mm
450mm
936mm
BOSCH 10H
BOSCH 13H
1.13 kPa
1.13 kPa
2.75 kPa
2.75 kPa
0.89 kPa
0.84 kPa
2.60 kPa
2.60 kPa
79 Mj/hr
104 Mj/hr
5 l/min
6.5 l/min
10 l/min
13 l/min
3.2 l/min
3.2 l/min
Dimensions
B
C
D
E
10H
533mm
240mm
68mm
13H
533mm
240mm
68mm
16H
533mm
240mm
82mm
BOSCH 16H
1.13 kPa
2.75 kPa
0.78 kPa
2.60 kPa
130 Mj/hr
8 l/min
16 l/min
3.2 l/min
4

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HydroPower 10H and is the answer not in the manual?

Questions and answers

Brian
January 20, 2025

Hot water drops out when cold is turned on

1 comments:
Mr. Anderson
February 4, 2025

Hot water may drop out when cold water is turned on in a Bosch HydroPower 10H because the water flow through the heater decreases, reducing its ability to maintain the required flow rate to heat the water effectively. This can cause the water temperature to drop or the heater to shut off if the flow rate falls below the minimum operating threshold.

This answer is automatically generated

Peter R Wise
March 29, 2025

How to change temperature

1 comments:
Mr. Anderson
March 29, 2025

To change the temperature on a Bosch HydroPower 10H, adjust the water flow:

- Turn the water flow adjustment anti-clockwise to increase water flow, which lowers the temperature.
- Turn it clockwise to decrease water flow, which increases the temperature.

This answer is automatically generated