Alien ALR-9650 Hardware Setup Manual

Rfid readers, cost effective smart antenna
Hide thumbs Also See for ALR-9650:

Advertisement

ALIEN TECHNOLOGY
®
ALR-9650
HARDWARE
SETUP GUIDE
February 2008
ALR-9650

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALR-9650 and is the answer not in the manual?

Questions and answers

Summary of Contents for Alien ALR-9650

  • Page 1 ALIEN TECHNOLOGY ® ALR-9650 HARDWARE SETUP GUIDE February 2008 ALR-9650...
  • Page 2 No part of this product documentation may be reproduced in any form or by any means without the prior written consent of Alien Technology Corporation and its licensors, if any. Third party software is copyrighted and licensed from Licensors. Alien, Alien Technology, the Alien logo, Nanoblock, FSA, Gen2Ready, Squiggle, the Squiggle logo, Nanoscanner and other graphics, logos, and service names used in this document are trademarks of Alien Technology Corporation in the U.S.
  • Page 3: Table Of Contents

    Requirements ............................17 Hardware Installation Procedure ......................18 System Operation: Software Control ......................20 Reader Interface Guide ........................20 Demonstration Software Guide ......................21 Alien RFID Academy ..........................21 APPENDIX A CLAUSE 6.2 OF SJT/11364....................22 ALR-9650 H ARDWARE ETUP UIDE DOC.
  • Page 4 ABLE OF ONTENTS (This page intentionally left blank) ALR-9650 H ARDWARE ETUP UIDE DOC. CONTROL #8102091-000 REV B...
  • Page 5: Chapter 1 Introduction

    Demo Software Guide – details installing and operating the Alien RFID Gateway demonstration software. Quick Upgrade Guide – briefly explains how to use the demonstration software to upgrade the ALR-9650. The ALR-9650 can only be upgraded through the LAN/PoE port. Developer’s Guides, Application Programming Interfaces and Example Code.
  • Page 6: Rfid Reader Overview

    PPENDIX RFID Reader Overview The Alien ALR-9650 RFID reader is designed to read and program any EPC Class 1 Generation 2 tag and issue event reports to a host computer system. The host computer can be locally connected to the reader via RS-232, or at a remote network location.
  • Page 7: Requirements

    Standard 120/220 VAC 50/60 Hz outlet and the model ALX-416-1 (PoE) or ALX-416-2 (24 Volt AC/DC) power supply (provided with the reader) Note: Only these supplies may be used to power the ALR-9650. Host software (Alien Gateway demo software, telnet terminal or your own...
  • Page 8: Specifications

    0°C to +50°C (32 °F to +122°F) Operating Environment Indoor operation only Software Support APIs, sample code, executable demo app (Alien Gateway) Protocol Support Comply with EPC Class 1 Gen 2 and 18000 – 6C Compliance Certifications FCC Part 15; FCCID: P65ALR9650; IOC: 4370A-ALR9650...
  • Page 9: Auxiliary Antennae

    12.95 watts minimum or using one of the power supplies listed below. Only the power supplies listed below may be used with the ALR-9650 reader. Operation with other power supplies is a violation of the conditions of the ALR- 9650 FCC license.
  • Page 10: Mechanical: Reader Physical Size

    Figure 1 - Outline Drawing of the ALR-9650 I/O Port Terminal Interface The ALR-9650 I/O port provides two digital inputs, two digital outputs and a ground return. The design provides protection against momentary over and reverse voltage application to the inputs or outputs and short circuit of the outputs.
  • Page 11 PERATION Unlike the Alien Enterprise Readers (ALR-9800 and ALR-9900) the ALR-9650 I/O’s are not optically isolated. Instead they are buffered internally. As a result the outputs can source up to 20 mA’s without the external supply required for the Enterprise Readers. Outputs should be protected from transients such as inductive kickback so as to not exceed the absolute maximum voltage allowed at the outputs.
  • Page 12: Rs-232 Port Pinouts

    OOKING AT EADER System Architecture External Antenna Host Digital Antenna Communication Control Receiver Switch Interface Circuitry Internal CP Antenna RF Source Modulator Figure 3 - System Architecture for the ALR-9650 Reader ALR-9650 H ARDWARE ETUP UIDE DOC. CONTROL #8102091-000 REV B...
  • Page 13: Chapter 2 Reader Hardware Installation And Operation

    One Ethernet cross-over cable for direct connection to a local host/PC CD-ROM containing demonstration software, user guides, documentation, Software APIs and example code An assortment of Class 1 Gen 2 UHF tags Figure 4 - ALR-9650 Developer’s Kit(Auxiliary Antenna and tag kit not shown) ALR-9650 H ARDWARE ETUP UIDE DOC.
  • Page 14: Reader I/O Panel

    LAN TCP/IP and PoE port Figure 5 - ALR-9650 Reader Connections Diagnostic LEDs The ALR-9650 includes diagnostic LEDs on the face of the reader to provide easy and convenient external indication for various operating conditions: On the Front Panel you will find: POWER (green) –indicates power is applied to the reader.
  • Page 15: Reader Antennas

    PERATION Reader Antennas The ALR-9650 includes an internal, circularly polarized antenna and an auxiliary antenna port. The Auxiliary port is found on the reader IO panel. It is a reverse- polarity TNC connector. Only antennae documented in this manual may be used...
  • Page 16: System Assembly And Bench Test

    Settings for RS-232 are 115200 Bits per second, 8 data bits, no parity, 1 stop bit, and no flow control. Start up terminal software on the PC, such as HyperTerminal with these settings, and be prepared to observe the reader's messages as it boots ALR-9650 H ARDWARE ETUP UIDE...
  • Page 17 WARNING: If you use an external power supply you must use the ALX- 416-1 PoE power supply or the ALX-416-2 AC/DC brick certified for use with the ALR-9650 by Alien Technology. Failure to do so voids the product warranty and violates the terms of the FCC license.
  • Page 18 SJT/11364 LAUSE PPENDIX LAN Drop Figure 10 – ALX-416-1 PoE Power Supply and Network Connection Diagram LAN Drop Figure 11 – ALX-416-2 24 V AC/DC Brick and Network Connection Diagram ALR-9650 H ARDWARE ETUP UIDE DOC. CONTROL #8102091-000 REV B...
  • Page 19 It uses a reverse polarity TNC connector. If using the Alien Gateway software, please note that ANT 0 is selected by default when first initialized.
  • Page 20: Bench Test Procedure

    --------------------------------------------- Once the reader boots and you see the "Boot>Ready!" prompt, pressing return will bring up the "Alien>" prompt. 9. Ensure the PC has compatible network settings. In order for you to be able to connect to the reader over TCP/IP, the host PC must be on the same subnet as the reader.
  • Page 21: Installation

    WARNING: If you do not use an 802.3af compliant network to supply DC power you must use the ALX-416 power supplies provided by Alien Technology. Failure to do so voids the product warranty and violates the terms of the FCC license.
  • Page 22: Hardware Installation Procedure

    (For example, a pallet tag may be the lowest tag position to be read, while the top-most case on a fully stacked pallet may represent your highest tag position.) ALR-9650 H ARDWARE ETUP UIDE...
  • Page 23 Alien Technology for use with the ALR-9650. 2. Select mounting position for reader. The ALR-9650 has been designed to provide reliable operation over its operating temperature range. This is enhanced by proper mounting of the reader during bench test and installation. When using the reader place it on a solid thermally conductive surface.
  • Page 24: System Operation: Software Control

    Bench Test Configuration topic. 8. Connect reader power. If you are using an 802.3af compliant network to power the ALR-9650 connect a standard LAN cable between the ALR-9650 LAN/PoE port and the 802.3af enable LAN drop or network switch. The green POWER LED will illuminate when power is on Note: If using an 802.3af compliant network it must be capable of...
  • Page 25: Demonstration Software Guide

    Alien RFID Academy Need to absorb RFID systems fast? Enroll in the Alien RFID Academy! In two or three days we'll share our practical expertise in RFID tags, antennas, readers, frequencies, systems, and protocols.
  • Page 26: Appendix A Clause 6.2 Of Sjt/11364

    SJT/11364 LAUSE PPENDIX Appendix A Clause 6.2 of SJT/11364 TUV 报告号: 30850411.001 翻 译: 英译中 以下是根据 2006年版 SJT/11364: 条款6.2之英译中: 注释: XRF 扫描结果和 RoHS 符合性声明是此次评估的一部分. ALR-9650 H ARDWARE ETUP UIDE DOC. CONTROL #8102091-000 REV B...

Table of Contents