Thermo King 1100 User Manual

Thermo King 1100 User Manual

Power inverter

Advertisement

TK 55872-19-OP (Rev. 0, 01/14)
Printed in U.S.A.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Thermo King 1100

  • Page 1 TK 55872-19-OP (Rev. 0, 01/14) Printed in U.S.A.
  • Page 2: Warnings, Cautions, And Notes

    Association safety standards. A Higher Wattage Inverter May Be Required To determine whether the Thermo King 1100 / 1500 / 2000 will operate a particular appliance or a combination of appliances, run a test. All inverters are designed to automatically shut down in the event of a power overload.
  • Page 3: Appliance Cautions

    Restart the inverter after it cools.  This Thermo King Power Inverter will only operate from a 12 Volt DC power source. Do not attempt to connect the inverter to any other power source, including any AC power source.
  • Page 4: Getting Started

    portable appliances use separate transformers or chargers that plug into AC receptacles to supply a low-voltage DC or AC output to the appliance. If the appliance label states that the charger or adapter produces a low-voltage DC or AC output (30 volts or less), there will be no problem powering that charger or adapter.
  • Page 5 These appliances can have startup loads of up to eight times the rated watts. Front Panel 1100 / 1500 / 2000 A. LCD Digital Display (See LCD Diagram on Page 6). B. ON / OFF Switch. Turns the inverter circuits ON and OFF.
  • Page 6: Lcd Diagram

    Low voltage c. Voltage overload. 4. Temperature shutdown. Rear Panel 1100 / 1500 / 2000 F. High-Speed Cooling Fan. When the temperature inside the inverter exceeds a preset limit, the Cooling Fan automatically turns on to cool the inverter. When the temperature reduces, the fan turns off.
  • Page 7: Sizing The Battery Bank

    Determining the DC Power Requirements Powering multiple appliances from the high-power 1100 / 1500 / 2000 inverter requires a 12 volt bank of batteries (several batteries). To calculate the approximate power in amps a 12 volt battery bank has to supply you need to know the current, or amps required for powering the continuous AC load.
  • Page 8: Operation

    These include: • AC appliance load and time in use (basic Amp Hour) • Cable gauge and length (cable losses) • Charge level of the batteries (between use, chargers have to be able to fully charge the batteries) • Temperature of the batteries (colder batteries provide fewer amps) •...
  • Page 9: Television And Audio Suggestions

    Television and Audio Suggestions Although all Thermo King Power Inverters are shielded and filtered to minimize signal interference, some interference with your television picture may be unavoidable, especially in weak signal areas. However, here are some suggestions that may improve reception: 1.
  • Page 10 AC (household current), using advanced MOSFET transistor in a full bridge configuration. This design provides this Thermo King Power Inverter with the capability to start and run difficult reactive loads, while providing excellent overload capability. The waveform that is generated by this conversion is a "modified sine wave"...
  • Page 11: Troubleshooting

    Troubleshooting PROBLEM: No Input Voltage Reason Solution Shut down inverter and Poor contact with battery disconnect. Clean terminals terminals. thoroughly and reconnect. Turn off inverter. Fix problem. Blown DC battery fuse(s). Replace fuse(s) with same type and rating. PROBLEM: Inverter is Shut Down Reason Solution Battery voltage below 10...
  • Page 12: Specifications

    Specifications: 1100 Specifications Description Output Continuous Watts (W) 1100 W +10W(USB) Surge Capacity (Peak Power) 2200 W Rated Input DC (V,A) 12VDC , 118A Input Voltage Range 10.5 to 15.5 VDC (60Hz±1) Rated Frequency (Hz) Rated Output AC (V,A) 12.5A(105-125) Rates Output USB (V,A) 2 * 5V/max.
  • Page 13 Specifications: 1500 Specifications Description Output Continuous Watts (W) 1500 W +10W(USB) Surge Capacity (Peak Power) 3000 W Rated Input DC (V,A) 12VDC , 161A Input Voltage Range 10.5 to 15.5 VDC (60Hz±1) Rated Frequency (Hz) Rated Output AC (V,A) 120V +/- 5% , 12.5A(105-125) Rates Output USB (V,A) 2 * 5V/max.
  • Page 14 Specifications: 2000 Specifications Description Output Continuous Watts (W) 2000 W +10W(USB) Surge Capacity (Peak Power) 4000 W Rated Input DC (V,A) 12VDC , 215A Input Voltage Range 10.5 to 15.5 VDC (60Hz±1) Rated Frequency (Hz) Rated Output AC (V,A) 120V +/- 5% , 16.7A(105-125) Rates Output USB (V,A) 2 * 5V/max.
  • Page 15: Warranty Summary

    Warranty Summary Contact your local Thermo King Dealer for Warranty Coverage terms. Warranty coverage may vary depending on how the equipment was purchased. For components purchased independent of a Thermo King APU, see Thermo King Aftermarket Warranty schedule, document TK51341. For equipment purchased with and covered under the Thermo...

This manual is also suitable for:

15002000

Table of Contents