TROUBLESHOOTING GUIDE

Trouble
Digital display not
illuminated.
Fan not operating
(digital display is
illuminated).
Fan running
continuously.
Poor evaporation of
water.
Bottle empties
completely
Bottle continues to
empty after complete
filling.
Bottle not emptying.
"CF" message does
not appear even when
filter is dirty or
humidifier performance
is clearly reduced.
Display blinks or fan
moves slightly when
humidifier is plugged in.
Alternating "F" and
room humidity
displayed.
Alternating "CF" and
room humidity
displayed.
Probable Cause
• No Power.
• Power button has not been
depressed.
• ROOM humidity level is not
3% or more below SET
humidity level.
• Reservoir is empty.
• SET humidity level is 65%.
• ROOM humidity level has
not reached 1% or more
above SET humidity level.
• CHECK FILTER (CF)
message flashing.
• Mineral buildup on wicking
filter.
• This is normal for initial
filling
• Air is entering water bottle.
• Spring Valve Assembly
damaged or missing post in
bottom of base.
• Base full of water.
• Loss of power or a power
failure has caused the CF
message to prematurely
reset.
• Normal
• Reservoir is empty.
• Wicking filter may be dirty. • Replace wicking filter.
10
Remedy
• Check 120 volt power source.
• Press power button once to turn on.
• Raise SET humidity level if desired.
• Increase fan speed.
• Fill humidifier with water.
• A SET humidity percentage of 65%
operates fan continuously. Adjust
SET level between 25% - 60%.
• Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
• Change to a fresh new wicking
filter.
• NOTE: Local water varies from area
to area and under certain
conditions minerals will build up
more rapidly in the wicking filter.
• Refill bottle for maximum run time.
• Check for leak in water bottle.
• Ensure fill valve position is turned to
closed and valve has no interfering
debris.
• Check position of bottle.
Reposition so that fill valve on
bottom of bottle is depressed
by post in bottom of base.
• The base will hold the contents of
water bottle (1.2gallons). Continue
to run humidifier to deplete water
from base.
• Replace wicking filter.
• No action required.
• Fill humidifier with water.
• Unplug unit for 30 seconds
and replug in to clear display.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MA0800 and is the answer not in the manual?

Questions and answers

eileen
January 29, 2025

how do i clean the **** on my aircare humidifer console?

1 comments:
Mr. Anderson
February 10, 2025

To clean the Aircare MA0800 humidifier console:

1. Empty the Unit: Remove and empty the water bottle and base.
2. Disinfect the Base and Bottle: Add 1 teaspoon (5 mL) of bleach to each and let sit for 20 minutes.
3. Do Not Mix Vinegar with Bleach: Use either bleach or vinegar separately.
4. Wipe with Vinegar or Bleach: Dampen a sponge with white vinegar or bleach and wipe the base.
5. Rinse Thoroughly: Ensure all cleaning solution is removed.
6. Dry Completely: Wipe all parts dry.
7. Replace the Wick Filter: Install a new wick if needed.
8. Reassemble the Unit: Put the humidifier back together.
9. Storage Instructions: If storing, discard the used wick, disinfect the unit, dry it, and store in a temperature-controlled place. Do not install a new wick until ready for use.

This answer is automatically generated

Richard J Medeiros
February 6, 2025

can humidifier be placed on the floor or does have to be elevated

1 comments:
Mr. Anderson
February 10, 2025

The Aircare MA0800 humidifier can be placed on the floor, but it should be on a level surface and not on soft carpet. It should also be positioned at least 4 inches away from walls or curtains and not placed directly in front of a hot air duct or radiator.

This answer is automatically generated

Paul Sass
February 21, 2025

Should I use warm or cold water to fill? This is the 2nd year of operation. Last year it worked flawlessly. With a new filter this year, it will not humidify more than 30% whereas it achieved 40% or more last year. What could cause the change?

Linda Brockman
March 21, 2025

what does CF mean?

1 comments:
Mr. Anderson
March 21, 2025

CF means "CHECK YOUR FILTER" and appears after 720 hours of use to remind you to check the wick filter. To reset the CF code, unplug the humidifier, check the wick, and replace it if necessary. Then, plug the unit back in.