Gas Control Valve
Figure 17. Honeywell VS8510E valve with millvolt control.
Pilot Burner Adjustment
1. Locate Pilot Adjustment Screw. (See figure 17.)
2. Adjust pilot screw to provide properly sized flame as shown in
figure 18).
3. After installing or servicing, leak test with a soap solution with
main burner on. Coat pipe and tubing joints, gasket etc. with soap
solution. Bubbles indicate leaks. Tighten any areas where the
bubbles appear until the bubbling stops completely.
Figure 18b. SIT Pilot Burner .
P/N XG0511
Maintenance
The following is a troubleshooting chart of possible problems:
PROBLEM
Noisy Pilot Flame
Pilot won't ignite
Main burner will
not light
If your fireplace still does not operate correctly, consult your dealer or
the manufacturer.
All service and repairs should be performed by a qualified
agency.
All spare parts and optional such as trim finishes and the wireless
infrared remote control are available from your local dealer or the
manufacturer.
Part Description
NG Gas Valve
LP Gas Valve
NG Pilot
LP Pilot
Thermocouple
Door
Front Burner NG
Rear Burner NG
Front Burner LPG
Rear Burner LPG
Log Set
Notes
Hotshot Gas Fireplace Insert
Troubleshooting
CORRECTIVE ACTION
Locate pilot adjustement screw on gas
control valve. The flame is decreased
by turning adjustment screw clock-
wise.
Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram figure 17.
1. Check wiring (see figure 17).
2. Check wall switch for proper con-
nection.
Spare Parts List
Part No .
RGC1044
RGC1043
RPA024
RPA025
RPG001
RDHS
RBT1099
RBT1100
RBT1101
RBT1102
RLGS15
Page 11
Need help?
Do you have a question about the Hotshot DHS and is the answer not in the manual?
Questions and answers