Problem
• Themessageshowsthattheinputsignalis
outofthespecifiedfrequencyrange.
Example:
fD: Dotclock
fH: Horizontalscanfrequency
fV: Verticalscanfrequency
●
Error code table
Error Code
0***
1***
*1**
*2**
*3**
*4**
*5**
**10
**11
**34
**61
**94
**95
18
Chapter3Troubleshooting
• ErrorsthatoccurredduringSelfCalibration
• ErrorsthatoccurredduringGrayscaleCheck
• ErrorsthatoccurredduringDICOM
• ErrorsthatoccurredduringCustom
• ErrorsthatoccurredduringCAL1
• ErrorsthatoccurredduringCAL2
• ErrorsthatoccurredduringCAL3
• Theproductmaximumbrightnessmaybelowerthanthetargetbrightness.
• Lowerthetargetbrightness.
• Theproductminimumbrightnessmaybehigherthanthetargetbrightness.
• Raisethetargetbrightness.
• Thesensormaynothavecomeoutduringcalibration,orlightmayhaveenteredthe
sensor.
• TurnofftheACadaptermainpower,waitforafewminutesbeforeturningthepower
backon,andthenexecuteSelfCalibration/GrayscaleCheckagain.
• Thesensormaynothavecomeout.
• Checkwhetherthereisanyforeignobjectnearthesensor.
• ExecuteSelfCalibration/GrayscaleCheckagain.
• SelfCalibration/GrayscaleCheckcannotbeexecutedduetothefollowingsettings:
- Thereisnosignalinputtotheleftscreen,andtheverticalresolutionoftheright
screenislowerthan2048dots.
- Theverticalresolutionsoftheleftandrightscreensarelowerthan2048dots.
• TheexecutionconditionsforSelfCalibration/GrayscaleCheckmaynotbeappropriate.
• Checktheexecutionconditionsandresetthemifnecessary.
Possible cause and remedy
• CheckwhetherthePCisconfiguredtomeettheresolution
andverticalscanfrequencyrequirementsofthemonitor
(see"2-1.CompatibleResolutions"(page13)).
• RebootthePC.
• Selectanappropriatesettingusingthegraphicsboard's
utility.Refertothemanualofthegraphicsboardfor
details.