This unit comes with interchangable gobos. When changing the
gobos please be very careful.
Caution! Never open the unit when in use. Always disconnect
the main power before attempting to change the gobos.
1. To change the gobo, remove the gobo access door.
2. When you remove the gobo access door you will see the
gobo wheel. Turn the gobo wheel with your hand until you
find the gobo you would like to change.
3. Using a pair of needle nose pliers, grab the fixture ring that
holds the gobo in place and remove the ring.
4. Once the ring is removed, carefully push the gobo out so that
it falls into your hand.
5. Carefully insert your new gobo and insert the fixture ring.
6. Reassemble the unit.
ADJ Products, LLC - www.adj.com - Inno Spot Elite Instruction Manual Page 24
Gobo Replacement
Inno Spot Elite
Disconnect the unit from its power source. Remove the power cord
from the unit. Once the cord has been removed, you will find that
the fuse holder is located inside the power socket. Insert a flat-head
screw driver into the power socket and gently pry out the fuse holder.
Remove the bad fuse and replace with a new one. The fuse holder also
has a holder for a spare fuse.
Inno Spot Elite
Due to fog residue, smoke, and dust cleaning the internal and exter-
nal optical lenses and mirror should be carried out periodically to
optimize light output. Cleaning frequency depends on the environ-
ment in which the fixture operates (I.e. smoke, fog residue, dust,
dew). In heavy club use we recommend cleaning on a monthly basis.
Periodic cleaning will ensure longevity, and crisp output.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Use a brush to wipe down the cooling vents and fan grill.
3. Clean the external optics with glass cleaner and a soft cloth every
20 days.
4. Clean the internal optics with glass cleaner and a soft cloth every
30-60 days.
5. Always be sure to dry all parts completely before plugging the unit
back in.
Inno Spot Elite
Trouble Shooting: Listed below are a few common problems that
you may encounter, with solutions.
No light output from the unit;
1. Be sure the external fuse has not blown. The fuse is located on
the rear panel of the unit.
2. Be sure the fuse holder is completely and properly seated.
Unit does not respond to sound;
1. Low frequencies (bass) should cause the unit to react to sound.
Tapping on the microphone, quiet or high pitched sounds may
not activate the unit.
ADJ Products, LLC - www.adj.com - Inno Spot Elite Instruction Manual Page 25