Page 2
SAFETY WARNINGS Do not place the device near to heaters, furnaces, other heat sources or under direct solar irradiation. Operate the device only in locations providing the tolerable operating temperature range 0°C~40°C. For cleaning, make sure the device is plugged off and only use a damp cloth without acid detergent. Install the device only in dry and dustproof surroundings.
5. OPERATING ELEMENTS 1. DVR, MON, CAM Operation mode toggle key: DVR: DVR and DVR main monitor control MON: DVR call and matrix monitor control CAM: Camera control on call and matrix monitors, telemetry control switching 2. 3-axis joystick Joystick for speed dome and telemetry receiver control 3.
6. KEYBOARD CONNECTORS RS-485 ports EKB-500 provides two independent RS-485 ports with 2 RJ-45 plugs each (loop-through). Pin assignment: Pin 1: 12 VDC Pin 3: RS-485 + Pin 6: RS-485 - Pin 7: Ground Pin assignment RJ-45 connector connector box Delivery comprises a connector box for RS-485 and 12 VDC power supply connection enabling power supply connection either directly to the EKB 500 keyboard or through the connector box.
7. INSTALLATION 7.1. General RS-485 bus installation EKB 500 uses a RS-485 simplex wiring; the signal is transferred via a single twisted pair line. CAT5 network cable is recommended, UTP version (unshielded) is sufficient for normal application. A shielded cable should be used if the installed cables are expected to be highly susceptible to interferences. The number of devices installed in one bus is limited to 32 (expandable through signal distributors), while max.
Page 9
RS-485 signal distributors may be used for star wiring. The maximum system cable length can also be expanded by using these distributors, physically providing a new RS-485 bus with 1200 m cable length each at every distributor output. In case the maximum number of 32 bus participants is exceeded, the number of connected devices can be increased by using RS-485 distributors.
7.4. Connection of Pelco-D / -P protocol-compatible devices Basic functions of speed domes and telemetry receivers compatible to Pelco-D / -P protocol can be controlled with the EKB 500 keyboard if a simplex RS-485 connection option is provided. For general connection, please refer to the chart illustrated above.
7.5 EDSR / EDR/ EDVR series’ DVR connection The EKB 500 keyboard can control the following digital video recorders: EDSR series (despite EDSR100 19" model) EDR-410/810/920/1640/EDVR series (MPEG-4 series) Installation with standard network cable: For short distances, EKB 500 can directly be connected using a standard network cable (patch cable, uncrossed!).
Page 13
System settings required for start-up: DVR: MENU > RS232/RS485: RS485 BAUDRATE 9600 BPS > Baud rate must be the same as baud rate of the respective EKB 500 port (default setting for both keyboard and DVR is 9600) STOPBIT PARITY NONE DATABIT RS232/RS485 ID...
7.6. Connection of several keyboards If several keyboards (max. 8) are used in a system, the RS-485 bus has to be looped through from keyboard to keyboard. Using both RS-485 interfaces (port 1 and 2), the 2nd bus connection must be effected separately as illustrated above.
8. MENU SETTINGS After electrical installation and start-up, both the connected devices and the keyboard itself have to be set up. Hold the Shift key and press the Menu key to enter the keyboard menu. COM Port Setting Device Setting Use the joystick and the Enter key for menu navigation.
EverFocus ED2200/2250, Samsung SCC-641/643/6405 Pelco-D Pelco-P ATTENTION: Protocol type setting is irrelevant for EverFocus DVR control; only baud rate setting is relevant! Press Enter to confirm the selection and Esc to cancel. Port : 1 Changed [ ENT ] to save 8.3.
Setup of the RS-485 interface used for telemetry RS485 Connected to cameras, port 1 or 2. Port : _ [ 1 or 2 ] Enter any value for fixed cameras (numeric entry compulsory). Press Enter to confirm the setting and Esc to cancel. Setup of DVR and video input to which the camera is connected Video Connected to (requires a DVR installation in the “DVR Setting”...
8.3.3. DVR Setting Define the digital video recorders to be controlled by the keyboard in this menu. DVRs can only be managed by EKB 500 after definition in this menu. By this, an administration of system access rights can be set up, as only DVRs defined in this menu are available for access. DVR number, entry 1 ~ 9999 (independent of DVR Name : _ _ _ _ DVR RS-485 address).
8.3.5. Monitor List & Delete This menu contains a list of all installed monitors as well as their settings. Furthermore, monitors can be deleted here. MENU > DEVICE SETTING > Total 005 Monitors MONITOR LIST & DELETE > Enter [ ENT ] to view list After pressing the Enter key, the first monitor is displayed.
8.3.7. Non-listed devices This function is currently not supported by RS-485 EEPBus. Use this menu to approve / disapprove the control of devices not defined in the menu. MENU > DEVICE SETTING > NON-LISTED-DEVICE > Enter Allow Operation w/o Keep the default setting “No Operation w/o list” at any time, list [ ↑...
8.4.3. Lock password If this password is activated, the keyboard will lock after 30 seconds with no keyboard operation. Any keypress after locking will display a password inquiry at the LCD display. MENU > KEYBOARD SETTING > LOCK PASSWORD > Enter Input new Password : Enter an 8-character password.
8.4.6. Keypad test Use this menu for testing the keys’ functionality. MENU > KEYBOARD SETTING > KEYPAD TEST > Enter Press the keys to be checked. _ _ _ _ _ _ _ _ _ _ ] Pressed If the keys work correctly, the LCD display shows the [ Esc ] to exit key function in clear text.
9. OPERATION 9.1. DVR operation EKB-500 provides a separate keypad for DVR control. The keys correspond to the EverFocus DVR front panel keys as regard to labelling and functionality. Besides these keys, further keys like MENU or Enter are required for different functions.
The range of functions varies, depending on the DVR model and firmware version. The essential functions are described below; for further details please refer to the DVR manual. Please note that this description does not provide a full function description of the EverFocus DVRs. Function...
9.1.3. Main monitor (MAIN) operation in DVR mode The camera and monitor definition within the keyboard menu is irrelevant for the main monitor (MAIN) operation. As the operation is effected in DVR mode, CAM resp. MON switching is not necessary. Select the camera by entering the channel number (DVR video input) via the numeric keypad.
MENU > DEVICE SETTING > CAMERA SETTING for speed dome / telemetry receiver connection settings EKB 500 is optimised for EverFocus EPTZ series speed dome control. Furthermore, basic functions of other supported speed dome types can be operated. The following operating elements are available for camera control:...
9.2.1 EverFocus EPTZ series The following functions are available after CAM : 0001 MON : 0001 camera selection in CAM-MON mode: [ CAM / MON / DVR ] EPTZ dome operation outline Function Keys / operation Open dome menu Shift (hold) + MENU...
9.2.1.1. EPTZ on-screen display Start EPTZ menu: MENU Switch between the settings: Shift (hold) + JOYSTICK Change the settings: Shift (hold) + JOYSTICK Leave the menu: Menu item EXIT > Enter or Clr (hold) + MENU 9.2.1.2. Positions (presets) Save presets Shift (hold) + POSITION Camera:0001 Save to >...
Start preset Camera:0001 go to POSITION > enter preset number > Enter Position:___[1-192] 9.2.1.3. Home position The home position is the position (preset) which is approached after a pre-defined duration upon last speed dome operation. Back to home if no Set (hold) + HOME action for ___Minute >...
9.2.1.5. Preset tours The EPTZ series supports up to 16 programmable preset tours with up to 16 presets each. For these tours, 2 operation modes are available: 1) Mode 1 (One way): after approaching all programmed presets, the tour restarts at the first programmed preset.
9.2.1.6. Alarm contact settings This function allows the EPTZ dome alarm contact assignment to presets or preset tours. Program alarm / preset / tour link Link Alarm:_ [1-4] to F1 > enter alarm contact number 1 ~ 4 ↑↓ ↑↓]:___ ↑↓...
9.2.2. EverFocus ED 2200/2250, Pelco-P, Samsung El. SCC-641/643/6405 operation Required protocol type in "COM PORT SETTINGS": A-TYPE / SAMSUNG /Pelco-P 9.2.2.1. On-screen display Start menu: MENU Switch between the settings: Shift (hold) + JOYSTICK Change the settings: Shift (hold) + JOYSTICK...
9.2.2.4. Autopan End stop definition Define both the end stops and the autopan speed in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model. Start A-B autopan Speed:___[1-239] A.Pan > enter pan speed 1~ 239 [ENT] to start.
9.2.3.2. Presets Save presets Shift (hold) + POSITION Camera:0001 Save to > enter preset number > Enter Position:___[1-192] Define preset parameters Set Camera:0001 Set (hold) + POSITION Position:___[1-192] > enter preset number > Enter Enter the preset dwell time within preset-tours Set Position:001 from 1~239 seconds Dwell:___[1-239]...
9.2.3.3. Autopan End stop definition Define both the end stops and the autopan speed in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model. Activate A-B autopan Speed:___[1-239] A.Pan > enter pan speed 1~ 239 [ENT] to start.
9.2.3.5. Pattern / Preset Tour Define patterns, which also can contain a preset tour, in the speed dome’s on-screen display. For further details, please refer to the manual of the respective model. Activate pattern Camera:0001 Run Tour:__[1-16] Tour Enter > enter pattern number > ATTENTION: At some third party domes with implemented Pelco-D the Preset tour starts with alternative command: POSITION >...
RS-485 2 independent RS-485 ports with 2 RJ-45 sockets each RS-232 1 x RS-232, Sub-D9 socket (service) RS-485 protocols EverFocus, ED2200/2250, Samsung Electr., Pelco-D, Pelco-P Power source 12 VDC +-10%, via power supply 230 VAC Power consumption 10 W max.
Page 38
Chiba city 261-7118, Japan www.everfocus.com TEL : +81-43-212-8188 FAX : +81-43-297-0081 www.everfocus.com Your EverFocus product is designed and Ihr EverFocus Produkt wurde entwickelt und manufactured with high quality materials and hergestellt mit qualitativ hochwertigen Materialien components which can be recycled and reused.
Need help?
Do you have a question about the EKB500 and is the answer not in the manual?