Airrex HSC-14 User Manual

Airrex HSC-14 User Manual

Airrex air conditioner
Hide thumbs Also See for HSC-14:

Advertisement

A A I I R R R R E E X X A A I I R R C C O O N N D D I I T T I I O O N N E E R R
▶ Thank you for purchasing an AIRREX AIR CONDITIONER.
BEFORE operation please read this user' s manual carefully.
▶ Keep this manual readily available.
▶ It is ESSENTIAL that you read the 'NOTES ON SAFETY'carefully
before use and follow them at all times.
▶ The Air Conditioners are specified for use on a 115V. 60Hz.1ph for
models HSC-14/18/24, and 220V. 60Hz. 1ph for model HSC-24A
single phase power supply. You must check that the local
electricity supply is the same and have the appropriate plug fitted
by a qualified electrician.
▶ The Warranty form is on Page 15. Please complete it now and keep
in a safe place.
▶ We have a policy of continual improving to our products.
The contents (features and specifications) in this manual are
therefore subject to change without notice.
USER' S MANUAL
HSC-14/18/24/24A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HSC-14 and is the answer not in the manual?

Questions and answers

Summary of Contents for Airrex HSC-14

  • Page 1 ▶ The Air Conditioners are specified for use on a 115V. 60Hz.1ph for models HSC-14/18/24, and 220V. 60Hz. 1ph for model HSC-24A single phase power supply. You must check that the local electricity supply is the same and have the appropriate plug fitted by a qualified electrician.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS ■ SAFETY INSTRUCTIONS ■ DESCRIPTION ·Front View ·Back View ·Control Panel ■ OPERATING INSTRUCTIONS ·On/Off Operation ·Selection of Area/Room or Spot Cooling ·Economic Mode ·Temperature Control ·Off Timer ·Indicator and Operational Error Alerts ■ CLEANING AND MAINTENANCE ■...
  • Page 3: Safety Instructions

    = You must NOT. You MUST. WARNING Use a 115V. 60Hz.(HSC-14/18/24), 220V. 60Hz(HSC-24A) 1 Phase power supply only. (Wrong supply may cause a fire and / or shock hazard) Securely plug into an grounded outlet. (Unless earthed, may cause electric shock) Do not use a damaged power cable, plug or socket.
  • Page 4 SAFETY NOTICE CAUTION Do not place cooler on uneven, unstable or inclined surface. (This could cause malfunction) When storing the cooler, ensure that it is kept in a dry, cool place. (To prevent corrosion and malfunction) If not being used for some time or if lightening is present, always unplug from power.
  • Page 5: Description

    EXTERIOR DESCRIPTION FRONT VIEW FLEXIBLE DUCT OUTLET (COLD AIR) HANDLE DIGITAL CONTROLLER ELECTRIC PANEL (ACCESS BY AUTHORISED SERVICE PERSONNEL ONLY) POWER PLUG CASTERS (FRONT LOCKABLE) BACK VIEW CONDENSER OUTLET (HOT AIR) EVAPORATOR FILTER AMBIENT AIR INTAKE. CONDENSER FILTER WATER LEVEL INDICATOR TO CHECK WATER LEVEL OF THE CONDENSATE TANK.
  • Page 6: Control Panel

    CONTROL PANEL FUNCTIONS ⑩ ⑦ ⑧ ⑪ ⑫ ⑨ ③ ④ ⑤ ⑥ ⑬ ② ① ① Power : Use to power On / Off. ② : Raises or lowers temperature and/ or sleep (off) time. ③ Cool : Use to select cooling mode. ④...
  • Page 7: Operating Instructions

    OPERATION RUNNING & STOP 1. START BY PRESSING THE ‘POWER’BUTTON. ·Cooler will start up automatically. ·To STOP the unit, press the ‘POWER’button once again. 2.To change fan speed, press the ‘Low’button. 3.If you wish to operate on fan only, press the ‘COOL’button. To resume cooling, press the ‘COOL’button again.
  • Page 8: Selection Of Area/Room Or Spot Cooling

    SELECTION of AREA/ROOM or SPOT COOLING To reduce the temperature of the entire room select 'Area/Room'. For ‘targeted’cooling of machinery, servers, or people etc. select ‘Spot Cooling’ . 1. If you want to display room temperature, 2. If you want to change temperature unit push cool and button simultaneously ℉...
  • Page 9: Temperature Control

    TEMPERATURE CONTROL OPERATION 1. When power is ON, the setting temperature is displayed. Default of setting temperature is as below. •50℉ in Spot Mode. •60℉ in Room Mode. 2. When you push either button, the setting temperature is changed. 3. The display showing the set temperature will blink 3 times.
  • Page 10: Off Timer

    HOW TO SET THE ‘OFF’ TIMER. This function enables you to set the length of time you want the cooler to operate. You can set the time period from 30min. to 24 hours in 30min. and 1 hour increments. 1. When cooler is operating, press the ‘Off Timer’ button and set the length of time you want by pressing ▲...
  • Page 11: Indicator And Operational Error Alerts

    'ERROR' and W ARNING INDICATORS The machine’ s safety devices will automatically signal any problems via the display window on the control panel. The information below shows how to read these signals. 1. WATER FULL- Display shows “FU” When the water container is full, “FU”is displayed and the LED “Water Full”light will be on.
  • Page 12: Cleaning And Maintenance

    CLEANING AND MAINTENANCE CLEANING THE AIR FILTERS 1. To remove filters, slide up a little ① and pull towards you ②. 2. Clean the filters with water or compressed air. 3. Clean evaporator and condenser units with a vacuum cleaner or compressed air. MAINTENANCE 1.
  • Page 13: Trouble Shooting / Accessories

    ● Clean heat exchanger ● Obstacle against inlet side ● Remove and allow 50cm.clearance ● Ambient temp. too high ● Use only below 105℉ (over 105℉) ACCESSORIES MODEL ITEM DRAWING HSC-14/18/24/24A 12inch Diam. DUCT 5inch OPTION 9.8 ft. DUCT COVER COLD (FINISHING COLLAR)
  • Page 14: Specifications

    SPECIFICATIONS H H S S C C - - 1 1 4 4 H H S S C C - - 1 1 8 8 H H S S C C - - 2 2 4 4 H H S S C C - - 2 2 4 4 A A BTU/h 13,600 16,800...
  • Page 15: Warranty

    W ARRANTY (Applicable to first retail purchaser only) AIRREX AIR CONDITIONERS give more reliable performance, comfort and durability the more they are used. They are built under a strict quality assurance regime which includes inspection both during and after production and exhaustive reliability testing.
  • Page 16 FAX : 1-469-574-7924 sales@airrexusa.com HEPHZIBAH CO.,LTD. 423-5 CHUNGCHUN-DONG, BUPYUNG-KU INCHEON, KOREA TEL : +82-32-509-5834 FAX : +82-32-502-5519 E-mail : airrex@hdtek.com Website : www.airrex.co.kr ● Designs and specifications of products are subject to change without prior notice for the improvement of products.

This manual is also suitable for: