Page 1
▶ The Air Conditioners are specified for use on a 115V. 60Hz.1ph for models HSC-14/18/24, and 220V. 60Hz. 1ph for model HSC-24A single phase power supply. You must check that the local electricity supply is the same and have the appropriate plug fitted by a qualified electrician.
= You must NOT. You MUST. WARNING Use a 115V. 60Hz.(HSC-14/18/24), 220V. 60Hz(HSC-24A) 1 Phase power supply only. (Wrong supply may cause a fire and / or shock hazard) Securely plug into an grounded outlet. (Unless earthed, may cause electric shock) Do not use a damaged power cable, plug or socket.
Page 4
SAFETY NOTICE CAUTION Do not place cooler on uneven, unstable or inclined surface. (This could cause malfunction) When storing the cooler, ensure that it is kept in a dry, cool place. (To prevent corrosion and malfunction) If not being used for some time or if lightening is present, always unplug from power.
EXTERIOR DESCRIPTION FRONT VIEW FLEXIBLE DUCT OUTLET (COLD AIR) HANDLE DIGITAL CONTROLLER ELECTRIC PANEL (ACCESS BY AUTHORISED SERVICE PERSONNEL ONLY) POWER PLUG CASTERS (FRONT LOCKABLE) BACK VIEW CONDENSER OUTLET (HOT AIR) EVAPORATOR FILTER AMBIENT AIR INTAKE. CONDENSER FILTER WATER LEVEL INDICATOR TO CHECK WATER LEVEL OF THE CONDENSATE TANK.
CONTROL PANEL FUNCTIONS ⑩ ⑦ ⑧ ⑪ ⑫ ⑨ ③ ④ ⑤ ⑥ ⑬ ② ① ① Power : Use to power On / Off. ② : Raises or lowers temperature and/ or sleep (off) time. ③ Cool : Use to select cooling mode. ④...
OPERATION RUNNING & STOP 1. START BY PRESSING THE ‘POWER’BUTTON. ·Cooler will start up automatically. ·To STOP the unit, press the ‘POWER’button once again. 2.To change fan speed, press the ‘Low’button. 3.If you wish to operate on fan only, press the ‘COOL’button. To resume cooling, press the ‘COOL’button again.
SELECTION of AREA/ROOM or SPOT COOLING To reduce the temperature of the entire room select 'Area/Room'. For ‘targeted’cooling of machinery, servers, or people etc. select ‘Spot Cooling’ . 1. If you want to display room temperature, 2. If you want to change temperature unit push cool and button simultaneously ℉...
TEMPERATURE CONTROL OPERATION 1. When power is ON, the setting temperature is displayed. Default of setting temperature is as below. •50℉ in Spot Mode. •60℉ in Room Mode. 2. When you push either button, the setting temperature is changed. 3. The display showing the set temperature will blink 3 times.
HOW TO SET THE ‘OFF’ TIMER. This function enables you to set the length of time you want the cooler to operate. You can set the time period from 30min. to 24 hours in 30min. and 1 hour increments. 1. When cooler is operating, press the ‘Off Timer’ button and set the length of time you want by pressing ▲...
'ERROR' and W ARNING INDICATORS The machine’ s safety devices will automatically signal any problems via the display window on the control panel. The information below shows how to read these signals. 1. WATER FULL- Display shows “FU” When the water container is full, “FU”is displayed and the LED “Water Full”light will be on.
CLEANING AND MAINTENANCE CLEANING THE AIR FILTERS 1. To remove filters, slide up a little ① and pull towards you ②. 2. Clean the filters with water or compressed air. 3. Clean evaporator and condenser units with a vacuum cleaner or compressed air. MAINTENANCE 1.
● Clean heat exchanger ● Obstacle against inlet side ● Remove and allow 50cm.clearance ● Ambient temp. too high ● Use only below 105℉ (over 105℉) ACCESSORIES MODEL ITEM DRAWING HSC-14/18/24/24A 12inch Diam. DUCT 5inch OPTION 9.8 ft. DUCT COVER COLD (FINISHING COLLAR)
W ARRANTY (Applicable to first retail purchaser only) AIRREX AIR CONDITIONERS give more reliable performance, comfort and durability the more they are used. They are built under a strict quality assurance regime which includes inspection both during and after production and exhaustive reliability testing.
Page 16
FAX : 1-469-574-7924 sales@airrexusa.com HEPHZIBAH CO.,LTD. 423-5 CHUNGCHUN-DONG, BUPYUNG-KU INCHEON, KOREA TEL : +82-32-509-5834 FAX : +82-32-502-5519 E-mail : airrex@hdtek.com Website : www.airrex.co.kr ● Designs and specifications of products are subject to change without prior notice for the improvement of products.