PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300 MODEL VSP100 V U L C A N - H A R T C O M P A N Y , P . O . B O X 6 9 6 , L O U I S V I L L E , K Y 4 0 2 0 1 - 0 6 9 6 , TEL. (502) 7 7 8 - 2 7 9 1...
STOCK POT INSTALLATION, OPERATION, SERVICE & PARTS IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED.
STOCK POT INSTALLATION, OPERATION, SERVICE & PARTS INSTALLATION, OPERATION, SERVICE & PARTS MANUAL STOCK POT RANGES MODELS VSP100, VSP200 & VSP300 INDEX PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE Your Vulcan Stock Pot Range is produced with quality The manufacturer suggests that you thoroughly read this workmanship and material.
A minimum of propane gases. front clearance of 24" is required. The Model VSP100 Range has one burner, Model The range must be installed so that the flow of combus- VSP200 has two burners, and Model VSP300 has three tion and ventilation air will not be obstructed.
STOCK POT INSTALLATION, OPERATION, SERVICE & PARTS The gas inlet is located at the rear and lower left side After piping has been checked for leaks, all piping of the range. To ensure maximum operating efficiency, receiving gas should be fully purged to remove air. the range must be connected with a gas supply line as large or larger ID (net inside diameter) than the ⁄...
STOCK POT INSTALLATION, OPERATION, SERVICE & PARTS ADJUSTMENTS Air Supply Pilot Adjustment Air supply is controlled by an air shutter on the front of each burner. Increase the air shutter openings until the Turn burner valves on to remove air from the line. Turn flame on the burner begins to “lift.”...
STOCK POT INSTALLATION, OPERATION, SERVICE & PARTS OPERATION CONTROLS Shutdown The burner is in two sections, controlled by two heavy For daily shutdown, turn burner valves to OFF position. duty infinite control valves. The center “Star” section (Fig. 2) is one separate burner with an input of 55,000 For seasonal shutdown, extinguish pilot and turn burner BTU/hr.
STOCK POT INSTALLATION, OPERATION, SERVICE & PARTS MAINTENANCE LUBRICATION All valves and thermostats must be checked and Contact personnel qualified to install and repair gas lubricated periodically. Contact your Vulcan-Hart equipment for all other maintenance. authorized servicer. SERVICE SHUTOFF VALVE...
Parts may be ordered only from your authorized parts and service depot. For assistance in locating your nearest authorized parts and service depot, contact: Product Service Department Vulcan-Hart Company 2006 Northwestern Pkwy. Louisville, KY 40203 FAX# (502) 778-8510...
Page 10
STOCK POT INSTALLATION, OPERATION, SERVICE & PARTS VSP100 STOCK POT RANGE – 10 –...