Service and Adjustment
Lower
Thermostat
Adjustment
The lower thermostat
is adjustable
if a different
water tempera-
ture
is desired.
Read
all warnings
in the
'Temperature-
Regulation"
section before proceeding.
(cont'd)
Failure to install and maintain a new properly listed tempera-
ture-pressure relief valve will release the manufacturer from any
claim which might result from excessive temperature or pressure,,
The
slotted
adjustment
(using a screwdriver)
can be turned
clockwise
(_)
to increase
the temperature
setting
or
counter
clockwise
to (k,._)
decrease the temperature
setting.
g.
LOWER THERNOSTAT
ADJUSTABLE
THROUGH
LOWER ACCESS PANEL
Temperature=Pressure
Relief
Valve Operation
The temperature-pressure
retiefvaJve
must be manually
operated
at least once a year..
TEHPERATURE-PRESSURE
RELIEF VALVE
DISCHARGE
PIPE
AWARNING
If the temperature-pressure
relief valve on the appliance
weeps or discharges periodically, this may be due to ther *'
real expansion. Your water heater may have a check valve
installed in the water line or a water meter with a check
valve. Consult your local Sears Service Center for further
information.
Do not plug the temperature-pressure
relief
valve.
Draining
The water heater should
be &ained
if' being shut down during
freezing
temperatures.
Also periodic
draining
and cleaning
of
sediment
from the tank may be necessary.
• Befbre beginning
turn
"OFF"
the electric
power supply to
the water heater
AWARNING
HAZARD
OF ELEC_K!
Before removing|
any access panels or servicing the water heater,
make|
sure the electrical
supply to the water heater is turned|
"OFF"°
Failure to do this could result in DEATH,
SERI-|
OUS BODILY INJURY, OR PROPERTY DAHAGE.
J
" CLOSE the cold water inlet valve to the water heater._
-
OPEN
a nea*by hot water faucet and leave open to allow for
draining.
,
Connect
a hose to the drain
valve and
terminate
to an
adequate
drain or outdoors.
OPEN
the water
heater
drain
valve
to allow
for tank
draining.
NOTE: If the water heater
is going
to be shut down and
drained fot an extended
period,
the drain valve should
be
left open with hose connected
allowing
water to terminate
to an adequate
drain.
AWARNING
The temperature-pressure
relief valve must be manually
operated at least once a year. Caution should be taken to
ensure that (I) no one is in front of Or around the outlet
of the temperature-pressure
relief valve discharge line,
and (2) the water manually discharged will not cause any
property
damage
or bodily injury. The water
may be
extremely
hot.
If after manually operating the valve, it fails to completely
reset and continues to release water, immediately
close
the cold water inlet to the water heater, follow the drain-
ing instructions,
and replace the temperature-pressure
relief valve with a new one.
17
Close the drain valve+
Follow
"Filling
the Water
Heater"
instructions
in the
"Installation
Instructions"
section+
Turn "ON" power to the water heater.
I
ACAUTION
Never use this water heater
unless it is completely
fult
water. To prevent damage to the tank and heating ele-
I ment,
the tank must be filled with water. Water
must
I flow from the hot water
faucet
before turning
"ON"
L_power.