Centurion R3 User Manual

Centurion R3 User Manual

Rotary swing gate operator
Hide thumbs Also See for R3:

Advertisement

R3 and R5 user guide
TM
TM
ROTARY
SWING GATE
OPERATOR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R3 and is the answer not in the manual?

Questions and answers

lungelo
January 17, 2025

how to programme a new remote

E.R. CRONJE
January 25, 2025

If gate close the motor running to close the gate

1 comments:
Mr. Anderson
February 10, 2025

No, the Centurion R3 motor does not run continuously when closing the gate. It follows a mode-based operation system. In STANDARD mode, a trigger starts movement, and a second trigger stops it, while a third reverses direction. In CONDOMINIUM and PIRAC modes, the gate will close automatically, but it does not indicate continuous running—only controlled operation based on triggers and conditions.

This answer is automatically generated

Summary of Contents for Centurion R3

  • Page 1 R3 and R5 user guide ROTARY SWING GATE OPERATOR...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents Company Profile ..............3 Introduction .
  • Page 3: Company Profile

    © CENTURION SYSTEMS (PTY) LTD 2007 Centurion Systems (Pty) Ltd. reserves the right to make changes to the products described in this manual without notice and without obligation of Centurion Systems (Pty) Ltd. to notify any persons of any such revisions or changes. Additionally, Centurion Systems (Pty) Ltd. makes no representations or warranties with respect to this manual.
  • Page 4: Introduction

    Introduction Introduction A CENTURION GATE AUTOMATION system is a quality product designed to give many years of trouble free use, provided it is correctly installed and maintained. This guide highlights the features and operation of the CENTURION R3 and R5 AUTOMATIC SWING GATE systems to ensure that, YOU, the user will get the most from your system.
  • Page 5: Principles Of Operation

    Principles of Operation The CENTURION R3 and R5 rotary swing gate operators are both powered by a 12V DC motor using a maintenance free, lead acid battery as the primary power source. The battery is charged via a 220V mains supply or a solar panel.
  • Page 6: Features & Functions

    Features & Functions Introduction The R3 and R5 Rotary arm operators are fitted with the CP75 controller. The controller synchronizes the functions of the gate operator. Modes of Operation There are four different modes of operation that can be selected. Only one mode can be selected at any one time.
  • Page 7: Intercom Pushbutton

    If the gate is opening with the automatic closing facility selected, and the transmitter is then pressed, the gate will stop, but will close automatically after the auto-close delay time. Intercom Push button (Optional) Press to open gate A visitor outside the gate requests entrance Gate opened from intercom pushbutton inside house Most automatic gate installations are fitted with an intercom which provides for communication between the house and the gate.
  • Page 8: Pedestrian Keyswitch (Optional)

    Anti-crushing Device The R3 and the R5 operator incorporates an electronic anti-crushing mechanism that will sense if a person or vehicle has obstructed the gate. If the anti-crushing mechanism of a single or double gate system is activated while the gate(s) are opening, the operator of the obstructed gate will stop.
  • Page 9: Multiple Collision

    Gate opening onto an obstruction Only the obstructed gate stops. Gates closing onto object. Both gates automatically re-open. MULTIPLE COLLISION If the system is obstructed repeatedly 4 times after the initiation of an opening cycle, and before the master motor gets back to its fully closed position, the gate(s) will stop and remain locked in position for 1 minute.
  • Page 10: Auto-Close Override

    AUTO-CLOSE OVERRIDE INTERCOM PUSHBUTTON or REMOTE Press and hold the gate release for 3 seconds to override the auto-close. If the auto-close function has been selected it can be conveniently and easily overridden for one cycle. This override feature is activated by holding down the remote control push-button, or intercom gate release button (approximately 3 seconds), when opening the gate, until the gate stops.
  • Page 11: Gate Status Indication

    After this time the gate system can be reactivated but will shut off immediately again if a battery low condition persists. CONTACT YOUR LOCAL GATE AUTOMATION SPECIALIST OR CENTURION SYSTEMS IF YOU DISCOVER THAT THE BATT LOW SIGNAL GIVEN BY THE LED INSIDE THE HOUSE CONTINUES TO RE-OCCUR.
  • Page 12: Security (Courtesy) Light Timer

    If the gate status indicator has not been fitted, there is an equivalent LED mounted on the CP75 marked STATUS, which can be used as a fault finding aid. NOTE: The controller's battery low protection will ensure that only the motors are prevented from drawing current from the battery.
  • Page 13: Lightning Protection

    system will operate normally.This is an added security feature should the property be unattended for an extended length of time. Lightning Protection The CP75 controller has on-board lightning protection. The protection circuitry is based on a design developed in conjunction with the CSIR. It is however important to realise that the controller's protection only functions correctly if an adequate lightning earth is fitted during installation.
  • Page 14 To release the manual override, proceed as follows: Unlock and remove the operator cover. Lift the controller housing fitted to a MASTER motor. This is not necessary when releasing a SLAVE motor. Swing open the manual release dust cover. Insert the allen key provided into the manual release mechanism and rotate it clockwise to release the gearbox (approximately 12 turns) Page 14...
  • Page 15 To re-engage the drive (disengage manual override): Rotate the dust cover back into position. Unscrew the allen key (counter-clockwise) until the top of the screw is flush with the top of the shaft. Lower the controller housing into position (not Replace the operator cover and lock it in position.
  • Page 16: Basic Maintenance

    Basic Maintenance Basic Maintenance The CENTURION system is designed to be maintenance free. However, there are some basic checks that should be carried out regularly (every six months) which will increase the long term reliability of the system, and prevent false triggering of the protection systems leading to erratic operation of the gate.
  • Page 17 Fuse(250mA Size 5x20mm) Battery Charger In domestic applications the R3 and R5 are battery driven. Each system has a built in battery charger which automatically maintains the battery in a fully charged state. The casing may get hot when the charger is in operation.
  • Page 18: Specifications

    Specifications Specifications SPECIFICATION Voltage (with CP84ER5V01 CP84ER5V01 power supply unit) 220V AC ±10% 50Hz AC Current draw (with CP84ER5V01 CP84ER5V01 power supply unit) 120mA DC Current draw (Max) Maximum solenoid lock current draw 3.5 rpm Output shaft rotational speed Maximum output torque 140Nm 100* Maximum number of operations per day (Average)
  • Page 19: Troubleshooting Guide

    THAT THE MAINS SUPPLY TO THE SYSTEM HAS BEEN ISOLATED. NB: As this product is used outside of the control of the manufacturer, CENTURION SYSTEMS (PTY) LTD, it cannot be held responsible for consequential damage as a result of the end user attempting to maintain the unit without the assistance of a qualified installer.
  • Page 20   Gate does not operate but Motor fuse blown on the Replace blown fuses R3- the relays on the controller control card. 8 A m p s l o w b l o w. S i z e "click" momentarily.
  • Page 21 SYMPTOM CAUSE ACTION input LED's are OFF. They must only light up when the c o r r e s p o n d i n g i n p u t i s activated.  Try operating the system using the TEST pushbutton on the control card.
  • Page 22 SYMPTOM CAUSE ACTION Consult your installer if the problem persists.   Origin position has been Make sure that nobody has accidently used the origin shifted. adjustment tool to release the manual override. Consult your installer should this be suspected. ...
  • Page 23: Product Guarantee

    Product Guarantee Product Guarantee All CENTURION products are manufactured with extreme care, thoroughly inspected and tested. They are guaranteed for a period of 12 months, provided that proof of purchase documentation is submitted with any claim. The guarantee only covers repair, components and labour, provided that the equipment is returned to our workshop.
  • Page 24 Sharecall 0860-CENTURION (0860 236 887) Head Office: +27 11 699 2400 Sharecall Technical Support 0861 003 123 or +27 11 699 2481 from 07h00 to 18h00 (GMT+2) (Sharecall numbers applicable when dialed from within South Africa only) 0.07.A.0100_22072013 www.centsys.com...

This manual is also suitable for:

R5

Table of Contents