Sharp Plasmacluster IG-A20E Operation Manual
Sharp Plasmacluster IG-A20E Operation Manual

Sharp Plasmacluster IG-A20E Operation Manual

Plasmacluster ion generator
Hide thumbs Also See for Plasmacluster IG-A20E:

Advertisement

Plasmacluster is a trademark of SHARP Corporation.
IG-A20E
IG-A40E
SHARP CORPORATION
Osaka, Japan
プラズマクラスターイオン発生機
取扱説明書
Plasmacluster Ion Generator
OPERATION MANUAL
Plasmacluster-Ionen-Generator
BEDIENUNGSANLEITUNG
Générateur d'ions Plasmacluster
MODE D'EMPLOI
Plasmacluster Ion Generator
IG-A20E
BEDIENINGSHANDLEIDING
Ионный генератор Plasmacluster
РУКОВОДСТВО ПО
ЭКСПЛУАТАЦИИ
IG-A40E
この取扱説明書をよくお読みのうえ、
正しくお使いください。
Read and keep this manual carefully.
Bitte lesen Sie diese Anleitung und
Veuillez lire et enregistrer ces instructions.
bewahren Sie sie auf.
Lees en bewaar deze instructies.
Прочтите данное руководство и
сохраните его.
Printed in Japan
TINS-A390KKRZ 09JK
JP
1

Advertisement

Table of Contents
loading

Summary of Contents for Sharp Plasmacluster IG-A20E

  • Page 1 プラズマクラスターイオン発生機 取扱説明書 Plasmacluster Ion Generator OPERATION MANUAL Plasmacluster is a trademark of SHARP Corporation. IG-A20E Plasmacluster-Ionen-Generator IG-A40E BEDIENUNGSANLEITUNG Générateur d’ions Plasmacluster MODE D’EMPLOI Plasmacluster Ion Generator IG-A20E BEDIENINGSHANDLEIDING Ионный генератор Plasmacluster РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ IG-A40E この取扱説明書をよくお読みのうえ、 正しくお使いください。 Read and keep this manual carefully.
  • Page 2: Table Of Contents

    * Replacement is required approximately every 2 years (17,500 hours) when operated 24 hours a day. IG-A20E and IG-A40E will stop operating after about 26 months (19,000 hours) if the Plasmacluster Ion Generating Unit is not replaced.
  • Page 3: Important Safety Instructions

    • DO NOT use the unit near gas appliances or fi replaces. • If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp authorized Service Center or qualifi ed person in order to avoid a hazard.
  • Page 4: Parts Name

    PARTS NAME Louvers (Air outlet of Plasmacluster Ion) High density Plasmacluster Ion is discharged forward. (Do not put anything in front of the unit.) Plasmacluster Ion Generating Unit (Inside) Please open the cover only when replacing the Plasmacluster Ion Generating Unit. (See page E-9) Power cord Filter (Air Intake)
  • Page 5: Installation Position

    INSTALLATION POSITION Place the main unit on a smooth, stable surface in a room, and insert the plug into an outlet. Please note the required clearance. UPSIDE more than 60cm BACKSIDE more than 6cm SIDE more than 60cm SIDE more than 60cm Installation Guidance •...
  • Page 6: How To Install The Unit

    25mm or less. * S i z e o f a n c h o r b o l t diameter is 8mm or less. anchor bolts 552mm(IG-A20E) 898mm(IG-A40E) Put the main unit on the anchor bolts and tighten surely with washer anchor bolt and nut.
  • Page 7: Operation

    OPERATION * This operation manual is based on IG-A40E. The operation is same as IG-A20E. Open the cover of Control Panel. In case that the cover is fixed by a screw, take out the rubber cover and a screw, and open the cover of control panel.
  • Page 8: Cleaning And Maintenance

    Pull out the fi lter from bottom of the main unit and remove dust by using a vacuum cleaner or similar tools. Filter • When the fi lter is very dirty, please wash with water IG-A20E Filter (1pc) or using mild kitchen detergent. IG-A40E Filter (2pcs) * A filter is not disposable item, often CAUTION clean the fi...
  • Page 9: Plasmacluster Ion Generating Unit Replacement

    Plasmacluster Ion Generating Unit Please dispose the used Plasmacluster Ion Generating Unit according to any local laws and regulations. Model IZ-CA40E (for IG-A40E) -materials- Number IZ-CA20E (for IG-A20E) • Case: Acrylonitrile Butadiene Styrene (ABS) • Unit: Polybuthylene Terephthalate (PBT), Electric parts.
  • Page 10: How To Replace The Plasmacluster Ion Generating Unit

    HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT * When replacing the Plasmacluster Ion Generating Unit, be sure to turn off the main unit, unplug the power cord, and never handle the plug with wet hands. Remove the rubber cover and unscrew the center screw of the Ion Generator Cover.
  • Page 11: How To Replace The Plasmacluster Ion Generating Unit

    P u s h a n d u n l o c k t h e connector, take out the connector in the direction of the arrow. IG-A20E Plasmacluster Ion Generating Unit without sensor. IG-A20E : 1pc IG-A40E : 3pcs without sensor (1pc) with sensor (1pc) Plasmacluster Ion Generating Unit with sensor. IG-A40E...
  • Page 12: Specifications

    SPECIFICATIONS IG-A20E IG-A40E Model Power supply 220-240V, 50/60Hz Fan speed HIGH MED. HIGH MED. Power consumption (W) Operating noise level (dBA) Airfl ow volume (m /hour) Applicable fl oor surface area (m 25,000 12,000 7,000 25,000 12,000 7,000 Ion density (ions/cm...
  • Page 13: Troubleshooting

    • Dust may block the fi lter, clean the fi lter. Failure fl ashing (blue) Unplug and ask the store you purchased or Sharp Sevice Center. fl ashing (blue) The Plasmacluster Ion Generator releases The discharged air has odor. a small trace of ozone which may produce odor.
  • Page 14 If the product is used for business purposes and you want to discard it: Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling.