If the information in these instructions is not followed exactly a fire or explosion may result causing
DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
Do not try to light any appliance
Do not touch any electric switch. Do not use any telephone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home where
not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
Prior to first fire: Clean gold surfaces with a glass cleanser and soft cloth to prevent staining from fingerprint oils.
1445 North Highway
Colville, WA 99114
COLUMBIA BAY
DIRECT VENT GAS INSERT
40-5/8
SAVE THESE INSTRUCTIONS
WARNING!
property damage, personal injury or loss of life.
FOR YOUR SAFETY
appliance.
WHAT TO DO IF YOU SMELL GAS
A Division of Hearth Technologies Inc.
Part #250-6240 03/28/01
28-9/16
Tested and
O-T L
Listed by
C
OMNI-Test Laboratories, Inc.
ahpfireup.com
aladdinhearth.com
Beaverton
Oregon USA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COLUMBIA BAY and is the answer not in the manual?

Questions and answers

Summary of Contents for Quadra-Fire COLUMBIA BAY

  • Page 1 COLUMBIA BAY DIRECT VENT GAS INSERT 40-5/8 28-9/16 Installation, Venting, Operation & Maintenance Manual SAVE THESE INSTRUCTIONS WARNING! If the information in these instructions is not followed exactly a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2 Columbia Bay Direct Vent Gas Insert WELCOME ALADDIN HEARTH PRODUCTS welcomes you to our tradition of excellence! In choosing a Quadra-Fire appli- ance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs.
  • Page 3 Columbia Bay Direct Vent Gas Insert CUSTOMER NOTES MODEL NAME QUADRA FIRE COLUMBIA BAY INSERT SERIAL NUMBER DATE PURCHASED After completing your warranty card, attach receipt and warranty stub here. DEALERSHIP WHERE PURCHASED DEALER PHONE ADDITIONAL INFORMATION REGARDING THE INSTALLATION OF YOUR FIREPLACE:...
  • Page 4: Table Of Contents

    Columbia Bay Direct Vent Gas Insert TABLE OF CONTENTS SAFETY & RATINGS: Safety Notices ...........5 Ratings Plate.............6 SPECIFICATIONS: Vent system approvals........7 System Components.........7 Dimensions ............7 Minimum Firebox Opening ........7 Clearances to Combustibles ......7 INSTALLATION: Connection of venting ........9 Installation Diagrams.........10 Vent Cap Height Requirements ......11...
  • Page 5: Safety Notices

    Columbia Bay Direct Vent Gas Insert SAFETY NOTICES • This unit is not for use with solid fuel. DO NOT place Many of the components within this gas insert are designed anything inside the firebox other than the brickset, logset, specifically for safety purposes.
  • Page 6: Ratings Plate

    Columbia Bay Direct Vent Gas Insert RATINGS & LISTINGS THIS INFORMATION IS LOCATED ON A METAL HANG TAG ATTACHED TO INSERT WITH A CHAIN. SERIAL NO. Tested and Beaverton O-T L Listed by Oregon USA A Division of Hearth Technologies Inc.
  • Page 7: Specifications

    SYSTEM COMPONENTS Part Number Description 840-0380 Columbia Bay Direct Vent Gas Fired Insert - Natural Gas (Firebox only) DVIK33 Flex Kit includes 923K, 991, and Flex 3302. Flex 3302 Flex Kit (Includes (2) 3”x30’ Chimney Liner Flex) 923GK 3”...
  • Page 8: Installation

    Columbia Bay Direct Vent Gas Insert MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS When finishing the fireplace NEVER OBSTRUCT OR MODIFY THE AIR INLET/OUTLET OPENINGS IN ANY MANNER. While a hearth extension may be desirable for aesthetic reasons, it is not required for gas wall heaters per ANSI or CAN/CGA testing standards.
  • Page 9: Connection Of Venting

    Columbia Bay Direct Vent Gas Insert INSTALLATION CONNECTING THE VENT PIPE. Tools and building supplies normally The damper of the masonry or factory-built chimney required for installation. must be removed or fixed open to install the appliance. Tools Before installing the 3” flex vent pipe, mark or label the Pliers exhaust pipe at both ends.
  • Page 10: Installation Diagrams

    Columbia Bay Direct Vent Gas Insert INSTALLATION Figures 2 and 3 show typical installations of the appliance. Termination Cap Adaptor Exhaust Air Vent Pipe V=10 ft. Minimum Exhaust Air 35 ft. Maximum Mantel Panel Set Intake Air Inlet Air Vent Pipe Insulation Electrical &...
  • Page 11: Vent Cap Height Requirements

    Columbia Bay Direct Vent Gas Insert INSTALLATION VENT CAP HEIGHT REQUIREMENTS GAS LINE INSTALLATION A gas line must be run into the existing fireplace for either a factory built fireplace or masonry. It is recommended that 1/2'' inside diameter black pipe be run into the fireplace through the right side.
  • Page 12: Lp Conversion

    Columbia Bay Direct Vent Gas Insert LP CONVERSION Manufacturer’s conversion kit supplied with the appliance is required for this procedure. NOTE: If converting this unit to propane, so do at this point of installation. WARNING! THE INSTALLATION OF THIS CONVERSION KIT MUST ONLY BE UNDER- TAKEN BY A QUALIFIED AND CERTIFIED GAS APPLIANCE INSTALLER.
  • Page 13 Columbia Bay Direct Vent Gas Insert LP CONVERSION, CONT. Remove front (if installed): FIG. 3 (1) Lift lid on top of insert; (2) Unlatch springs; (3) Door pivots on bottom, push in bottom and lift up. Remove logs, if installed.
  • Page 14: Optional Brickset

    Columbia Bay Direct Vent Gas Insert OPTIONAL BRICKSET INSTALLATION LOGSET INSTALLATION Order Part #841-0900 Remove log packaging from firebox. FIREBOX ENTRY Note: If using (LP) conversion kit or optional brickset, install prior to installing log set. (1) Lift lid on top of insert; (2) Unlatch springs; (3) Door pivots on bottom, push in bottom and lift up.
  • Page 15: Log Installation

    Columbia Bay Direct Vent Gas Insert LOG INSTALLATION Note: Placement of the Rock Woolshould be done with care and time, as this will effect the look of the fire when burning. PLACING ROCK WOOL 1) Tear the Rock Wool into pieces no larger than 1/2'' i diameter.
  • Page 16: Panel Set/Trim

    Columbia Bay Direct Vent Gas Insert PANEL SET INSTALLATION Three panel sizes are available: Part #841-0870 Standard Panel set, 28.5" x 40" Part #841-0880 Medium Panel Set, 31" x 44" Part #841-0890 Large Panel Set, 33" x 46" Back of Top Panel Included in Kit: (2) Angle Brackets and set screws;...
  • Page 17: Grille

    If desired, a thermostat may be installed to regulate the Slide screws on grille into openings on door face from Quadra-Fire Columbia Bay Insert. It is important to use a the back side. thermostat designed for millivolt operation. Do not connect Ensure that grille is aligned evenly left to right.
  • Page 18: Operation

    Columbia Bay Direct Vent Gas Insert OPERATION GAS LINE PURGING FLAME APPEARANCE Upon completing the gas line connection, a small amount Refer to the photo below. Flames should have a simlar of air will be in the lines. When first lighting the pilot light, appearance in height.
  • Page 19: Shutter Adjustment

    Columbia Bay Direct Vent Gas Insert OPERATION AIR SHUTTER ADJUSTMENT The air shutter is used to fine-tune the flame as necessary. CAUTION! The air shutter is shipped in the fully open position. The firebox bottom may become very hot Allow the unit to operate 15-20 minutes before making any during this adjustment procedure.
  • Page 20: Control Panel

    Columbia Bay Direct Vent Gas Insert CONTROL PANEL NORMAL OPERATING SOUNDS MAIN BURNER ....This control is used to turn the Blower...... The fireplace uses a 160 cfm blower fireplace on and off. to circulate heated air into the living area.
  • Page 21: Lighting Instructions

    Columbia Bay Direct Vent Gas Insert LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot that must be lit manually. When lighting the pilot, follow these instructions exactly.
  • Page 22: Glass Replacement

    Columbia Bay Direct Vent Gas Insert GLASS REPLACEMENT GOLD CLEANING All prints and smudges must be wiped clean from the gold trim prior to initial burn. If this is not done, these prints will be cured into the gold finish and set for the life of the heater.
  • Page 23: General Maintenance Procedures

    Columbia Bay Direct Vent Gas Insert YEARLY SERVICING PROCEDURES GENERAL Installation and repair should be done by a qualified service person. WARNING! Failure to inspect and maintain the The appliance and its venting system should be inspected fireplace may lead to improper combustion and before use and at least annually by a qualified agency.
  • Page 24: Blower & Blower Wiring

    Columbia Bay Direct Vent Gas Insert MAINTENANCE - BLOWER This appliance has a factory installed Blower, Junction Box, variable speed Rheostat Control Switch and Temperature Note: Sensor Switch for the Blower. To provide the 110-120 VAC, This appliance DOES require a 60 HZ are needed at the junction box.
  • Page 25: Valve/Pilot Wiring

    Columbia Bay Direct Vent Gas Insert VALVE/PILOT WIRING Pilot Ignitor Thermopile Thermocouple Rocker Switch / Wall Thermostat / Remote Push Button Ignitor Pilot Adjustment Variable Regulator Manifold Pressure Inlet Pressure PRE-USE CHECK Before operating this appliance, please review the safety precautions noted in this manual, as well as the items listed below: 1.
  • Page 26: Troubleshooting

    Columbia Bay Direct Vent Gas Insert TROUBLESHOOTING Problem Cause Corrective Action 1. Pilot will not ignite. A.Gas control knob Turn knob to PILOT and push in on the valve (see lighting isn’t turned to instructions on page 21). “PILOT”. B.Gas control knob Check the shutoff valve.
  • Page 27: Parts & Accessories

    The Aladdin Hearth Products limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Aladdin Hearth Products will repair or replace them. These items include, but are not limited to, steel and cast iron components, all gas burners, gas logs, combustion chambers, heat exchanger systems, stainless steel firebox components, gold plating, doors, glass damaged by thermal breakage, steel baffles and manifold tubes.